Laserfiche WebLink
F. In-Tank Gauging SIR Equipment: [9 Check this box if tank gauging is used only for inventory control. <br /> 0 Check this box if no tank gauging or SIR equipment isY"lel.2 2015 <br /> This section must be completed if in-tank gauging equipment is used to perform leak detection monitoring. <br /> N � ­`UAJH,1,, IIAL <br /> ANH I <br /> Complete thefollowing checklist: bm 70- <br /> 0 Yes 0 No* Has all input wiring been inspected for proper entry and termination,including testing for ground faults? <br /> 0 Yes 0 No* Were all tank gauging probes visually inspected for damage and residue buildup? <br /> El Yes 0 No* Was accuracy of system product level readings tested? <br /> 0 Yes 0 No* Was accuracy of system water level readings tested? <br /> 0 Yes 0 No* Were all probes reinstalled properly? <br /> _F_ 11 N_o7W_ere all items on the equipment manufacturer's maintenance checklist completed? <br /> Yes <br /> In the Section H,below,describe how and when these deficiencies were or will be corrected. <br /> G. Line Leak Detectors(LLD): Check this box if LLDs are not installed. <br /> Complete the following checklist: <br /> 0 Yes 0 No* For equipment start-up or annual equipment certification,was a leak simulated to verify LLD performance?(Check all <br /> 0 N/A that apply) Simulated leak rate:Q3 g.p.h.;[30.1 g.p.h;no 0.2 g.p.h. <br /> 0 Yes 0 No* Were all LLDs confirmed operational and accurate within regulatory requirements? <br /> 0 Yes 0 No* Was the testing apparatus properly calibrated? <br /> 0 Yes 0 No* For mechanical LLDs,does the LLD restrict product flow if it detects a leak? <br /> o N/A <br /> 0 Yes El No* For electronic LLDs,does the turbine automatically shut off if the LLD detects a leak? <br /> 0 N/A <br /> 5 Yes 0 No* For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system is disabled or <br /> 0 N/A disconnected? <br /> 0 Yes 0 No* For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system malfunctions or <br /> 0 N/A fails a test? <br /> 0 Yes 0 No* For electronic LLDs,have all accessible wiring connections been visually inspected? <br /> 0 N/A <br /> 0 Yes 0 No* Were all items on the equipment manufacturer's maintenance checklist completed? <br /> *In the Section H,below,describe how and when these deficiencies were or will be corrected. <br /> H. Comments: <br /> Monitoring System Certification Page of 12/07 <br />