My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2014-2015
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
J
>
JACK TONE
>
1501
>
2300 - Underground Storage Tank Program
>
PR0505264
>
COMPLIANCE INFO_2014-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/4/2021 4:36:01 PM
Creation date
6/23/2020 6:57:13 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2014-2015
RECORD_ID
PR0505264
PE
2361
FACILITY_ID
FA0006672
FACILITY_NAME
FLYING J TRAVEL PLAZA #618*
STREET_NUMBER
1501
Direction
N
STREET_NAME
JACK TONE
STREET_TYPE
RD
City
RIPON
Zip
95366
APN
22811017
CURRENT_STATUS
01
SITE_LOCATION
1501 N JACK TONE RD
P_LOCATION
05
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0505264_1501 N JACK TONE_2014-2015.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
382
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
..I� Amok <br /> IP San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California95205-6232 <br /> Telephone. (209) 468-3420 Fax. (209)468-3433 Web.wWW.sjgov.oqq/ehd <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Address: Date. <br /> r- A C K 7 0IN i F R D, IR, it/kik, 14, 2 0 1 <br /> "A P� <br /> File Review <br /> 126 HSC 25404(e)(4) Failed to report program data electronically o V Ei R ED COS <br /> On Site Records <br /> 201 CCR 2712(b) Failed to maintain alarm logs and/or records of follow up actions m V ci R o COS <br /> 202 CCR 2712(b) Failed to maintain cathodic protection test records on site for at least 6 1/2 years D V o R Lj COS <br /> 203 CCR 2712(b) Failed to maintain records of monitoring,repair,lining,and upgrades on site o V o R o COS <br /> 204 CCR 2712(i) Current monitoring plan approved by the EHD not found on site o V o R D COS <br /> 205 CCR 2712(i) Operating permit not on site o V ii R D COS <br /> 206 HSC 25294,25295 Failed to record or report unauthorized release in appropriate time frame o V E3 R o COS <br /> 207 CCR 2715 Designated operator did not inspect all required items and/or the inspection reports not completed m V o R o COS <br /> 208 CCR 2715 Designated operator monthly inspection reports not maintained on site for at least 12 months oV oR o COS <br /> 209 CCR 2715(o Designated operator employee training not performed or log not kept nV oR o COS <br /> 210 CCR 2715(f)(2) Unstaffed facility failed to have or implement a training program approved by the EHD oV ii R Ei COS <br /> 211 HSC 25281.5(b)(2) Unburied fuel piping at marinas not visually inspected at least daily or log not kept oV oR ii COS <br /> 212 HSC 25281.5(b)(3) Unburied emergency generator fuel piping not visually inspected at least monthly or log kept ciV oR o COS <br /> UST System Observations <br /> 301 HSC 25292-1 UST system is not operated to prevent unauthorized release,including spills and overfills oV uR o COS <br /> 302 HSC 25291(b) UST system incapable of detecting leak from primary into secondary containment(pre-Jul 2003) ❑V o R o COS <br /> 303 HSC 25290.2(d) Monitoring system not maintained to detect entry into secondary containment(Jul 2003-Jun 2004) Ei V Ei R Ei COS <br /> 304 HSC 25290.1(d) Monitoring system not maintained to detect entry into secondary containment(after Jul 2004) a V o R m COS <br /> 305 HSC 25290.1(e) VPH monitoring of the interstitial spaces of the UST system is not maintained o V o R o COS <br /> 306 CCR 2630(d) Monitoring equipment is not installed or maintained to detect a leak at the earliest opportunity m V c R o COS <br /> 307 CCR 2632(c) Monitoring system of the interstitial space of a double walled system not maintained o V o R o COS <br /> 308 CCR 2636(f) Failed to maintain a continuous monitoring system that activates an audible and visual alarm ❑V o R o COS <br /> 309 CCR 2636(f)(1) Monitoring in the UDCs failed to activate an audible and visual alarm or stop the flow at the UDC ci V Ei R o COS <br /> 310 CCR 2636(f)(1) Sensor in a turbine sump failed to activate an audible and visual alarm or stop the flow product a V o R o COS <br /> 311 CCR 2636(f)(5) Piping is not fail-safe outside UDCs or fails to stop flow of product at dispenser inside UDCs o V o R o COS <br /> 312 CCR 2636 Failed to properly program or operate leak detection equipment o V ❑R ❑COS <br /> 313 CCR 2638(o Failed to affix a tag sticker on monitoring equipment certified,repaired,or replaced u V ❑R ❑COS <br /> 314 CCR 2631(a) Primary containment not tight(pre-Jul 2003) o V o R Ei COS <br /> 315 HSC 25290.2(c)(1) Primary containment not tight(Jul 2003-Jun2004) o V o R o COS <br /> 316 HSC 25290.1(c)(1) Primary containment not tight(after Jun 2004) o V o R o COS <br /> 317 HSC 25290.1,25290.2, Secondary containment not tight o V o R Ei COS <br /> 25291 <br /> 318 R 2636(a) Failed to have secondary containment LiV oR o COS <br /> Received bynspector: Phone: r Date: <br /> 5"1 C.2 01 <br /> (initial): rl��2 JELENA MAt',40"), REHS <br /> Page 2 of 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.