My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2016-2017
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
J
>
JACK TONE
>
1501
>
2300 - Underground Storage Tank Program
>
PR0505264
>
COMPLIANCE INFO_2016-2017
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/11/2021 8:36:01 AM
Creation date
6/23/2020 6:57:20 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2016-2017
RECORD_ID
PR0505264
PE
2361
FACILITY_ID
FA0006672
FACILITY_NAME
FLYING J TRAVEL PLAZA #618*
STREET_NUMBER
1501
Direction
N
STREET_NAME
JACK TONE
STREET_TYPE
RD
City
RIPON
Zip
95366
APN
22811017
CURRENT_STATUS
01
SITE_LOCATION
1501 N JACK TONE RD
P_LOCATION
05
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0505264_1501 N JACK TONE_2016-2017.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
344
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
F <br /> SAN JOAQUIN COUNTY <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone: (209)468-3420 Fax: (209)468-3433 Web:www.sicehd.cam; <br /> Facility Facility Inspection <br /> Name: ;\� ` c® Phone: C)Cj _5q`i 'tj 1I Date: 3 <br /> Facility CERS <br /> � `R ID: <br /> Address: ` , r Z o C c <br /> Inspection Title: Phone: PS <br /> Contact: <br /> Inspection \ Program: 1 <br /> Type: <br /> Consent,,Given For: Consent <br /> Alasl5ection b-P otos ❑ Sampling Given By: ami �C.w fi <br /> Service Tech Exp. Designated Exp- <br /> Onsite: ®r"C_ Date: r�` Operator. L Date: <br /> Service Technician w <br /> Manufacturer's Training: \ ' 1 1 <br /> CCR=California Code of Regulations HSC=Heath and Safety Code CFR--Code of Federal Regulations <br /> ��pp V=Violation R=Repeat COS=Corrected on site during inspection <br /> NO- <br /> WINVAa <br /> W'184 <br /> x�_ K..Yrt w k '-:,^�'rd � Dm.x+Lxrhv .t <br /> 101 HSC 25284 No permit to operate(V650) ° ° ° <br /> 102 HSC 25284(a)(3) No written agreement between tank owner and tank operator to monitor the tank system(V735) ❑ ❑ ❑ <br /> 103 HSC 25292.2 Current financial responsibility documents not submitted(V720) ° ° ° <br /> 104 CCR 2711 UST operating permit application for facility and tank information not submitted or current(V651) ❑ ❑ o <br /> 105 CCR 2632(d)(1) Failed to have an approved UST monitoring plan(V852) ° ° ° <br /> 106 CCR 2632(d)(2) Failed to have an approved UST response plan(V853) ° ° ° <br /> 107 CCR 2632(d)(1)(C) Plot plan/site map not submitted or failed to completely show where mopitoring is performed(V655) ❑ ❑ ❑ <br /> 108 CCR 2637(f), Failed to notify the EHD 48 hours prior to conducting testing(V671) ❑ ° ° <br /> 2638(e) <br /> 109 CCR 2637 Failed to test secondary containment(V660) ° ° ° <br /> 110 CCR 2637(e) Failed to submit secondary containment test report within 30 days(V662) ❑ ° ° <br /> 111 CCR 2638(a) Failed to test monitoring and leak detection equipment annually(V659) ° ° ° <br /> 112 HSC 25284,2 Failed to test spill containers annually(V661) ° ° ° <br /> 113 CCR 2638(d) Failed to submit monitoring system certification test report within 30 days(V823) Cl ° ° <br /> 114 CCR 2636(f) Failed to perform 0.1 gph annual line test for pressurized piping without fail safe or shut down(V663) ❑ ❑ ❑ <br /> 115 CCR 2715(a) Failed to inform the EHD of designated operator identification or change within 30 days(V658) ❑ ❑ ❑ <br /> 116 CCR 2715 Designated operator,service tech or installer did not possess current ICC certification(V848) ❑ ❑ ❑ <br /> 117 CCR 2663 Failed to inspect a lined or repaired steel tank within 10 years of lining and every 5 years after(V666) ❑ ❑ ❑ <br /> 118 CCR 2663 Failed to submit tank lining certification within 30 days or to conduct proper tests(V667) ❑ ❑ ° <br /> 119 HSC 25299 Documents were falsified or misrepresented(V657) <br /> 120 CCR 2635(d) Failed to submit UST Certification of Installation/Modification(V840) <br /> 121 CCR 2712(0 Failed to submit a written response within 30 days of receiving an inspection report(V804) ❑ ❑ ❑ <br /> 122 CCR 26310) Failure to submit UST system component statement of compatibility for substance stored(V721) ❑ ❑ ❑ <br /> 201 CCR 2712(b) Failed to maintain alarm logs and/or records of follow up actions(V725) ° ° ° <br /> 202 CCR 2712(b) Failed to maintain cathodic protection test records on site for at least 6 1/2 years(V733) ❑ ❑ ❑ <br /> 203 CCR 2712(b) Failed to maintain records of monitoring,repair,lining,and upgrades on site(V732) ❑ ° ° <br /> 204 CCR 2712(i) Current monitoring plan approved by the EHD not found on site(V734) ° ° ° <br /> 205 CCR 2712(1) Failure to have an approved UST response plan available onsite(V654) ❑ <br /> 206 CCR 2712 Failure to comply with UST operating permit conditions(V738) ° <br /> 207 HSC 25294 Failed to record unauthorized release from primary containment(V737) ° ° ° <br /> ReceivedInspector: Inspector W" y "s <br /> By(initial): C Phone: /ES'' `f 5 <br /> UST INSPECTION REPORT <br /> EHD 23-01 REV 07/28/16 Page 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.