e <br /> Aaron Hang [EH] <br /> From: William Reeck <wreeck@jonescovey.com> <br /> Sent: Thursday,June 22, 2017 11:09 AM <br /> To: Aaron Hang [EH] <br /> Cc: Joey Cupp; Miluska Cioffi; Bret Covey; Gregory Smith <br /> Subject: Pilot Flying J - Ripon - NoV Response <br /> Attachments: Job_7501882.pdf,T2 (Diesel) STP.JPEG;T3 (Diesel) STP.JPEG;T4 (87) STP.JPEG; Oil-Water <br /> seperator probe jpeg;T1 (Diesel) STP.JPEG; Return to Compliance.pdf <br /> Follow Up Flag: Follow up <br /> Flag Status: Flagged <br /> Good Morning Aaron, <br /> This email is in response to the NOV at Pilot Flying 1#618, located at 1501 N Jack Tone Rd, Ripon, CA 95366. In <br /> accordance with the Notice of Violation,Jones Covey Group has performed the following actions: <br /> • Violation 105—JCG has programmed the site's Veeder-Root and probe for the oil water separator to include <br /> high level alarm (90%)and overfill alarm at(95%). Both alarms were tested with passing results. <br /> • Violation 207—JCG has inspected the biodiesel transition sump on 6/16 and found the sump dry with no liquid. <br /> No evidence of leaking was observed, but staining on floor was found and observed to be gear oil leaking from <br /> blender pump. Gear oil has been cleaned. <br /> • Violation 309—Corrected onsite. No further action taken. <br /> • Violation 313—JCG has inspected the biodiesel transition sump on 6/16 and found the sump dry with no liquid. <br /> No evidence of leaking was observed, but staining on floor was found and observed to be gear oil leaking from <br /> blender pump. Gear oil has been cleaned. <br /> • Violation 315—JCG has inspected the sumps on T1-T4 on 6/16 with the following results: <br /> o T1-JCG found liquid and removed in sump that was determined to be diesel leaking from flanges.The <br /> flanges were tightened and no further leaking was observed. Confirmed sensor was on lowest point, <br /> locked and straight. Picture attached.We will continue to observe for any further leaking. <br /> o T2-JCG found liquid and removed in sump that was determined to be diesel leaking from flanges.The <br /> flanges were tightened and no further leaking was observed. Confirmed sensor was on lowest point, <br /> locked and straight. Picture attached.We will continue to observe for any further leaking. <br /> o T3—JCG found liquid and removed in sump that was determined to be diesel and water from leak <br /> detector vent port.Vent port has been re-installed &tightened with no further leaks observed. <br /> Confirmed sensor was on lowest point, locked and straight. Picture attached. We will continue to <br /> observe for any further leaking. <br /> o T4—JCG found liquid and removed in sump that was determined to be water. No leaks were observed. <br /> Confirmed sensor was on lowest point, locked and straight. Picture attached. <br /> • Violation 316—JCG has inspected the biodiesel transition sump on 6/16 and found the sump dry with no liquid. <br /> No evidence of leaking was observed, but staining on floor was found and observed to be gear oil leaking from <br /> blender pump. Gear oil has been cleaned. <br /> • Violation 318—Corrected onsite. No further action taken. <br /> Please find attached a copy of the signed return to compliance statement form of the original NoV, as well as the work <br /> order for this job. If there are any questions, please feel free to reach out to me. <br /> Thank you, <br />