My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2016-2017
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
J
>
JACK TONE
>
1501
>
2300 - Underground Storage Tank Program
>
PR0505264
>
COMPLIANCE INFO_2016-2017
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/11/2021 8:36:01 AM
Creation date
6/23/2020 6:57:20 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2016-2017
RECORD_ID
PR0505264
PE
2361
FACILITY_ID
FA0006672
FACILITY_NAME
FLYING J TRAVEL PLAZA #618*
STREET_NUMBER
1501
Direction
N
STREET_NAME
JACK TONE
STREET_TYPE
RD
City
RIPON
Zip
95366
APN
22811017
CURRENT_STATUS
01
SITE_LOCATION
1501 N JACK TONE RD
P_LOCATION
05
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0505264_1501 N JACK TONE_2016-2017.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
344
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB,January 2002 Page 2 of 2 <br /> 7. UNDER-DISPENSER CONTAINMENT(UDC)TESTING <br /> Test Method Developed By: ❑UDC Manufacturer ®Industry Standard ❑Professional Engineer <br /> ❑Other(Spec) <br /> Test Method Used: ❑Pressure ❑Vacuum ®Hydrostatic <br /> ❑Other(Spec) <br /> Test Equipment Used: IN CON TS-STS Equipment Resolution: +/-0.002" <br /> UDC# Disp. 14/15 UDC# UDC# UDC# <br /> UDC Manufacturer: Unknown <br /> UDC Material: Fiberglass <br /> UDC Depth: 30" <br /> Height from UDC Bottom to Top 1 13" <br /> of Hi hest Piping Penetration: <br /> Height from UDC Bottom to N/A-Not In UDC <br /> Lowest Electrical Penetration: <br /> Condition of UDC prior to D <br /> testing: <br /> Dry <br /> Portion of UDC Tested' 17" <br /> Does turbine shut down when <br /> UDC sensor detects liquid(both ❑Yes []No X NA ❑Yes ❑No ®NA ❑Yes ❑No X NA ❑Yes ❑No ®NA <br /> product and water)?* <br /> Turbine shutdown response time N/A <br /> Is system programmed for fail- ❑Yes []No ®NA ❑Yes ❑No ®NA ❑Yes ❑No ®NA ❑Yes ❑No ®NA <br /> safe shutdown?' <br /> Was fail-safe verified to be ❑Yes ❑No ®NA ❑Yes ❑No ®NA ❑Yes ❑No N NA ❑Yes ❑No ®NA <br /> operational?* <br /> Wait time between applying <br /> pressure/vacuum/water and 15min <br /> starting test <br /> Test Start Time: 10:40am <br /> Initial Reading(RI): 5.1204" <br /> Test End Time: 10:55am <br /> Final Reading RF): 5.1203" <br /> Test Duration: 15min <br /> Change in Reading(RF-RI): 0.0001" <br /> Pass/Fail Threshold or Criteria: +/-0.002" <br /> Test Result: ® Pass ❑Fail ❑ Pass ❑Fail ❑ Pass ❑Fail ❑ Pass ❑Fail <br /> Was sensor removed for testing? ®Yes ❑No ❑NA ❑Yes ❑No ®NA ❑Yes ❑No ®NA ❑Yes ❑No A NA <br /> Was sensor properly replaced and -W Yes ❑No ❑NA ❑Yes ❑No A NA ❑Yes ❑No LK NA ❑Yes ❑No A NA <br /> verified functional after testin ? <br /> Comments—(include information on repairs made prior to testing, and recommended follow-up for failed tests) <br /> This is a 6 month Re-Test for repairs made on Dispenser#14/15 UDC. Testing has passed &will be back on normal <br /> SB989 schedule. <br /> d. l <br /> i) 2017 <br /> t <br /> dw lite aid"E i 'k.L <br /> TH <br /> ' If the entire depth of the UDC is not tested,specify how much was tested. If the answer to aM of the questidns�mdicitod with an <br /> asterisk(*)is"NO"or"NA",the entire UDC must be tested. (See SWRCB LG-160) <br />
The URL can be used to link to this page
Your browser does not support the video tag.