My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2016
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
J
>
JACK TONE
>
1501
>
2300 - Underground Storage Tank Program
>
PR0505264
>
COMPLIANCE INFO_2016
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/11/2021 10:45:06 AM
Creation date
6/23/2020 6:57:24 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2016
RECORD_ID
PR0505264
PE
2361
FACILITY_ID
FA0006672
FACILITY_NAME
FLYING J TRAVEL PLAZA #618*
STREET_NUMBER
1501
Direction
N
STREET_NAME
JACK TONE
STREET_TYPE
RD
City
RIPON
Zip
95366
APN
22811017
CURRENT_STATUS
01
SITE_LOCATION
1501 N JACK TONE RD
P_LOCATION
05
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0505264_1501 N JACK TONE_2016.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
366
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
L <br />I. Results of Vacuum/Pressure Monitoring Equipment Testing JUN 0 3 2016 <br />This page should be used to document testing and servicing of vacuum and pressure interstitial sensors. A copy o ft i -t e <br />be included with the Monitoring System Certification Form, which must be provided to the tank system ownprgper�tor�, e <br />owner/operator must submit a copy of the Monitoring System Certification Form to the local agency regulating UST systems <br />within 30 days of test date. <br />Model: TLS 350 <br />System Type: ❑✓ Pressure; ❑ Vacuum <br />S-1 Component(s) Monitored by this Sensor: <br />Bio Product <br />Sensor Functionality Test Result: 0 Pass; <br />❑ Fail <br />Interstitial Communication Test Result: ❑x Pass; ❑ Fail <br />S-2 <br />Component(s) Monitored by this Sensor: <br />19-20 Product <br />Sensor Functionality Test Result: 0 Pass; <br />❑ Fail <br />Interstitial Communication Test Result: El Pass; ❑ Fail <br />S-3 <br />Component(s) Monitored by this Sensor: <br />21-30 Product <br />Sensor Functionality Test Result: El Pass; <br />❑ Fail <br />Interstitial Communication Test Result: 0 Pass; ❑ Fail <br />Component(s) Monitored by this Sensor: <br />Sensor Functionality Test Result: ❑ Pass; <br />❑ Fail <br />Interstitial Communication Test Result: ❑ Pass; ❑ Fail <br />Component(s) Monitored by this Sensor: <br />Sensor Functionality Test Result: ❑ Pass; <br />❑ Fail <br />Interstitial Communication Test Result: ❑ Pass; ❑ Fail <br />Component(s) Monitored by this Sensor: <br />Sensor Functionality Test Result: ❑ Pass; <br />❑ Fail <br />Interstitial Communication Test Result: ❑ Pass; ❑ Fail <br />Component(s) Monitored by this Sensor: <br />Sensor Functionality Test Result: ❑ Pass; <br />❑ Fail <br />Interstitial Communication Test Result: ❑ Pass; ❑ Fail <br />Component(s) Monitored by this Sensor: <br />Sensor Functionality Test Result: ❑ Pass; <br />❑ Fail <br />Interstitial Communication Test Result: ❑ Pass; ❑ Fail <br />Component(s) Monitored by this Sensor: <br />Sensor Functionality Test Result: ❑ Pass; <br />❑ Fail <br />Interstitial Communication Test Result: ❑ Pass; ❑ Fail <br />Component(s) Monitored by this Sensor: <br />Sensor Functionality Test Result: ❑ Pass; <br />❑ Fail <br />Interstitial Communication Test Result: ❑ Pass; ❑ Fail <br />How was interstitial communication verified? <br />0 Leak Introduced at Far End of Interstitial Space;' ❑ Gauge; ❑ Visual Inspection; ❑ Other (Describe in Sec. J, <br />below) <br />Was vacuum/pressure restored to operating levels in all interstitial spaces? 0 Yes ❑ No (If no, describe in Sec. J, below) <br />J. Comments (500 characters max. use additional sheets if needed): <br />' If the sensor successfully detects a simulated vacuum/pressure leak introduced in the interstitial space at the furthest point from the <br />sensor, vacuum/pressure has been demonstrated to be communicating throughout the interstice. <br />Page 4 of <br />
The URL can be used to link to this page
Your browser does not support the video tag.