Laserfiche WebLink
MONITORING SYSTEM CERTIFICATION <br />For Use By All Jurisdictions Within the State of California <br />C. Certification - 1 certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' <br />guidelines. Attached to this Certification is information (e.g. manufacturers' checklists) necessary to verify that this information is correct <br />and a Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating such reports, I have also attached a <br />copy of the report; (check all that apply): ® System set-up in Alarm history report <br />Technician Name (print): Arturo Perez Signature: <br />Certification No.: 838509 License. No.: 804431 <br />Testing Company Name: Jones Covey Group, Inc. Phone No.:(_88� 972-7581 <br />Testing Company Address: 9595 Lucas Ranch Rd.#100 Rancho Cucamonga CA,91730 Date of Testing/Seryicing: 3 / 11 / 2 0 1 6 <br />Monitoring System Certification Page of 12/07 <br />Authority Cited: Chapter 6.7, Health and Safety Code; Chapter 16, Division 3, Title 23, California Code of <br />Regulations <br />This form must be used to document testing and servicing of monitoring equipment. A separate certification or report must be prepared for <br />each monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank system <br />owner/operator. The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br />A. <br />General Information <br />Facility Name: Pilot -Flying J #618 <br />Bldg. No.: <br />Site Address: 1501 North Jack Tone Road <br />City: Ripon Zip: 95366 <br />Facility Contact Person: Darren Thomas (Frazenhill) <br />Contact Phone No.: 20( 9 ) 559-4141 <br />Make/Model of Monitoring System: TLS -350 <br />Date of Testing/Servicing: 3 / 11 / 2 0 1 6 <br />B. <br />Inventory of Equipment Tested/Certified <br />Check the a ro riate boxes to indicatespecific a ui ment insi iected/serviced: <br />Tank ID: T#1 Bio -Diesel <br />Tank ID: T#2 - 87 Unleaded 12,000 gals <br />)C1 <br />In -Tank Gauging Probe. Model: 846391--109 <br />k❑ In -Tank Gauging Probe. Model: 847390-107 <br />Annular Space or Vault Sensor. Model: 794380-303 <br />❑ Annular Space or Vault Sensor. Model: <br />A] <br />Piping Sump / Trench Sensor(s). Model: 794380-2081794380-304 <br />❑ Piping Sump / Trench Sensor(s). Model: <br />93 <br />Fill Sump Sensor(s). Model: 794380-2081794380-304 <br />❑ Fill Sump Sensor(s). Model: <br />❑ <br />Mechanical Line Leak Detector. Model: <br />❑ Mechanical Line Leak Detector. Model: <br />❑ <br />Electronic Line Leak Detector. Model: <br />❑ Electronic Line Leak Detector. Model: <br />jd3 <br />Tank Overfill / High -Level Sensor. Model: OPw Flapper valve <br />❑ Tank Overfill / High -Level Sensor. Model: <br />❑ <br />Other(specify equipment t e and model in Section E on Pae 2). <br />❑ Other(specify equipment t e and model in Section E on Pae 2). <br />Tank ID: T#3-9112,00 gals <br />Tank ID: South Transition Sump <br />)0 <br />In -Tank Gauging Probe. Model: 847390-109 <br />❑ In -Tank Gauging Probe. Model: <br />❑ <br />Annular Space or Vault Sensor. Model: <br />❑ Annular Space or Vault Sensor. Model: <br />❑ <br />Piping Sump / Trench Sensor(s). Model: <br />)0 Piping Sump / Trench Sensor(s). Model: 794380-208/794380-304 <br />❑ <br />Fill Sump Sensor(s). Model: <br />❑ Fill Sump Sensor(s). Model: <br />❑ <br />Mechanical Line Leak Detector. Model: <br />❑ Mechanical Line Leak Detector. Model: <br />❑ <br />Electronic Line Leak Detector. Model: <br />❑ Electronic Line Leak Detector. Model: <br />❑ <br />Tank Overfill / High -Level Sensor. Model: <br />❑ Tank Overfill / High -Level Sensor. Model: <br />❑ <br />Other �specify equipment t e and model in Section E on Pae 2). <br />❑ Other(specify equipment t e and model in Section E on Pae 2). <br />Dispenser <br />lD: <br />DispenserlD: <br />❑ <br />Dispenser Containment Sensor(s). Model: <br />❑ Dispenser Containment Sensor(s). Model: <br />❑ <br />Shear Valve(s). <br />❑ Shear Valve(s). <br />❑ <br />Dispenser Containment Floats and Chain(s). <br />❑ Dispenser Containment Floats and Chains . <br />Dispenser <br />ID: <br />Dispenser lD: <br />❑ <br />Dispenser Containment Sensor(s). Model: <br />❑ Dispenser Containment Sensor(s). Model: <br />❑ <br />Shear Valve(s). <br />❑ Shear Valve(s). <br />Dis enser Containment Floats and Chains . <br />❑ Dis enser Containment Floats and Chains . <br />penserlD: <br />DispenserlD: <br />r <br />Dispenser Containment Sensor(s). Model: <br />:Dispenser <br />❑ Dispenser Containment Sensor(s). Model: <br />Shear Valve(s). <br />❑ Shear Valve(s). <br />Containment Float�sj and Chains <br />❑ Dis enser Containment Floats and Chains . <br />'If the facility contains more tanks or dispensers, copy this form. Include information for every tank and dispenser at the facility. <br />C. Certification - 1 certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' <br />guidelines. Attached to this Certification is information (e.g. manufacturers' checklists) necessary to verify that this information is correct <br />and a Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating such reports, I have also attached a <br />copy of the report; (check all that apply): ® System set-up in Alarm history report <br />Technician Name (print): Arturo Perez Signature: <br />Certification No.: 838509 License. No.: 804431 <br />Testing Company Name: Jones Covey Group, Inc. Phone No.:(_88� 972-7581 <br />Testing Company Address: 9595 Lucas Ranch Rd.#100 Rancho Cucamonga CA,91730 Date of Testing/Seryicing: 3 / 11 / 2 0 1 6 <br />Monitoring System Certification Page of 12/07 <br />