My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2010-2015
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
B
>
BANNER
>
6437
>
2300 - Underground Storage Tank Program
>
PR0506004
>
COMPLIANCE INFO_2010-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/12/2024 4:20:39 PM
Creation date
6/23/2020 6:57:45 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010-2015
RECORD_ID
PR0506004
PE
2361
FACILITY_ID
FA0007140
FACILITY_NAME
FLAG CITY SHELL*
STREET_NUMBER
6437
Direction
W
STREET_NAME
BANNER
STREET_TYPE
ST
City
LODI
Zip
95242
APN
05532019
CURRENT_STATUS
01
SITE_LOCATION
6437 W BANNER ST
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0506004_6437 W BANNER_2010-2015.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
426
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
[JECENED <br />OC 0 3 ?ry13 <br />SWRCB, January 2002 Page of <br />6. PIPING SUMP TESTING ENVIRONMENTAL <br />Test Method Developed By: ❑ Sump Manufacturer ❑ Industry Standard ngineer <br />❑ Other (Spec) <br />Test Method Used: ❑ Pressure ❑ Vacuum X Hydrostatic <br />❑ Other (Spec) <br />Test Equipment Used: Caldwell Level Change Indicator <br />EMEMMEMMMMMMMMMMMMEM <br />Equipment Resolution: .002 <br />Sump # 1-87 Sump # 2-91 <br />Sump # 3 -Diesel Sump # <br />SumpDiameter: 42" <br />42" <br />42" <br />Sump Depth: 54%19 <br />56" <br />61 1/219 <br />Sump Material: Fiberglass <br />Fiberglass <br />Fiberglass <br />Height from Tank Top to Top of 13" <br />14" <br />13" <br />Highest Piping Penetration: <br />Height from Tank Top to Lowest 16" <br />17" <br />16" <br />Electrical Penetration: <br />Condition of sump prior to testing: Dry <br />Dry <br />Dry <br />Portion of Sump Tested' Water Line 18" <br />Water Line 19" <br />Water Line 18" <br />Does turbine shut down when <br />sump sensor detects liquid (both Yes <br />Yes <br />Yes <br />product and water)?* <br />Turbine shutdown response time Not Alarmed <br />Not Alarmed <br />Not Alarmed <br />Is system programmed for fail-safe Yes <br />Yes <br />Yes <br />shutdown?* <br />Was fail-safe verified to be No <br />No <br />No <br />operational?* <br />Wait time between applying water 5 Minutes <br />5 Minutes <br />5 Minutes <br />and starting test: <br />Test Start Time: 8:45 <br />8:35 <br />9:35 <br />Initial Reading (Rj): .001 <br />.001 <br />.001 <br />Test End Time: 9:15 <br />9:05 <br />10:05 <br />Final Reading (RF): .001 <br />.001 <br />.001 <br />Test Duration: 30 Minutes <br />30 Minutes <br />30 Minutes <br />Change in Reading (RF-Ri): 0 <br />0 <br />0 <br />Pass/Fail Threshold or Criteria: .005/30 Minutes <br />.005/30 Minutes <br />.005/30 Minutes <br />Test Result: Pass <br />Pass <br />Pass <br />Was sensor removed for testing? Yes <br />Yes <br />Yes <br />Was sensor properly replaced and Yes Yes Yes <br />verified functional after testing? <br />Comments — (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />' If the entire depth of the sump is not tested, specify how much was tested. If the answer to as of the questions indicated with an <br />asterisk (*) is "NO" or "NA", the entire sump must be tested. (See SWRCB LG -160) <br />