SWRCB, January 2002 <br />I1 <br />5AMIKIJ-WhA U K11 W -W 910 M m is1\y F.11 1910 1 IAM-rtli lk"1M M -1i t Lri <br />SEP 2 of <br />Test Method Developed By: <br />L UDC Manufacturer <br />L Industry Standard X Professional Engineer <br />Water Level 8" <br />D Other (Specify) <br />Does turbine shut down when <br />UDC sensor detects liquid (both <br />product and water)?* <br />ENVIRONMENTAL HEAL <br />Test Method Used: <br />L Pressure <br />L Vacuum <br />X Hydra <br />N/A <br />L' Other (Spec) <br />N/A <br />N/A <br />Test Equipment Used: Caldwell Level Change Indicator <br />Yes <br />Equipment Resolution: .002 <br />Yes <br />MM0M <br />Was fail-safe verified to be <br />operational?* <br />No <br />No <br />No <br />UDC # 9&10 <br />UDC # 11&12 <br />UDC # 13&14 <br />UDC # 15&16 <br />UDC Manufacturer: <br />Bravo <br />Bravo <br />Bravo <br />Bravo <br />UDC Material: <br />Coated Steel <br />Coated Steel <br />Coated Steel <br />Coated Steel <br />UDC Depth: <br />9" <br />8" <br />9" <br />9" <br />Height from UDC Bottom to Top <br />Enters from bottom <br />Enters from bottom <br />Enters from bottom <br />Enters from bottom <br />of Highest Piping Penetration: <br />Height from UDC Bottom to Enters from bottom Enters from bottom Enters from bottom Enters from bottom <br />Lowest Electrical Penetration: <br />Condition of UDC prior to I Dry Dry Dry Dry <br />Portion of UDC Tested' <br />Water Level 8" <br />Water Level 7" <br />Water Level 8" <br />Water Level 8" <br />Does turbine shut down when <br />UDC sensor detects liquid (both <br />product and water)?* <br />No <br />No <br />No <br />No <br />Turbine shutdown response time <br />N/A <br />N/A <br />N/A <br />N/A <br />Is system programmed for fail- <br />safe shutdown?* <br />Yes <br />Yes <br />Yes <br />Yes <br />Was fail-safe verified to be <br />operational?* <br />No <br />No <br />No <br />No <br />Wait time between applying <br />water and starting test <br />5 Minutes <br />5 Minutes <br />5 Minutes <br />5 Minutes <br />Test Start Time: <br />9:45 <br />9:50 <br />9:55 <br />10:00 <br />Initial Reading (RI): <br />.001 <br />.001 <br />.001 <br />.001 <br />Test End Time: <br />9:15 <br />10:20 <br />10:25 <br />10:30 <br />Final Reading (RF): <br />.001 <br />.001 <br />.001 <br />.001 <br />Test Duration: <br />30 Minutes <br />30 Minutes <br />30 Minutes <br />30 Minutes <br />Change in Reading (RF-Ri): <br />0 <br />0 <br />0 <br />0 <br />Pass/Fail Threshold or Criteria: <br />.005/30 Minutes <br />.005/30 Minutes <br />.005/30 Minutes <br />.005/30 Minutes <br />Test Result: <br />Pass <br />Pass <br />Pass <br />Pass <br />Was sensor removed for testing? <br />No <br />No <br />No <br />No <br />Was sensor properly replaced and <br />verified functional after testing? <br />NA <br />NA <br />NA <br />NA <br />Comments — (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />' If the entire depth of the UDC is not tested, specify how much was tested. If the answer to am of the questions indicated with an <br />asterisk (*) is "NO" or "NA", the entire UDC must be tested. (See SWRCB LG -160) <br />