Laserfiche WebLink
1� 0 <br /> 4REDCPT Controller Manual <br /> SOFT FAULT DESCRIPTION <br /> Mechanical Pump Occurs when the controller load is at maximum and the controller <br /> Problem output frequency is less than a preset threshold. Once the <br /> controller goes into current-regulation mode, any condition that <br /> increases motor load current forces it to drive the frequency down. <br /> Once the low-threshold frequency is reached, this fault is <br /> indicated. High amps at certain frequencies may indicate pump <br /> problems, such as dragging impellers, bearings, or internal parts in <br /> the pump and motor. <br /> Neuron The CPT has two processors that must continually communicate. <br /> Communication If communication fails, then leak detection cannot successfully <br /> Failure operate. <br /> No Dispenser Occurs if the pump does not come on (no dispense-enable signal) <br /> Activity within 72 hours. This feature can be deactivated for sites with low- <br /> volume dispensers, such as kerosene systems. <br /> Open Circuit Open circuits are wiring faults between the controller and the <br /> motor. Detected if the drive is On and the output current is less <br /> than the Open-circuit detection threshold. The processor retries <br /> every 5 seconds. If five consecutive occurrences of open circuit <br /> are recorded, the alarm triggers and the pump shuts down. (Note: <br /> The first four occurrences are soft faults; the fifth is a hard fault.) <br /> Over-current Detected if, during any period of operation, the over-current fault of <br /> the power module is activated. The processor automatically l <br /> retries every 5 seconds. If five consecutive occurrences of over- <br /> current are recorded, the alarm triggers and the pump shuts down. <br /> (Note: The first four occurrences are soft faults; the fifth is a hard <br /> fault.) <br /> Over temperature Occurs if, during any period of operation, the over-temperature <br /> fault of the power module is activated (i.e., when the temperature <br /> inside the controller gets too hot, >100°C in the power module). <br /> This may indicate fan failure. The thermal-measuring device on <br /> the power module communicates the Inverter board's temperature <br /> to the processor; if the Inverter board's temperature exceeds <br /> 100°C, the pump shuts down. (Note: The first four occurrences <br /> are soft faults; the fifth is a hard fault.) <br /> Peer In tandem operation, communication between the two CPT <br /> Communication Controllers must continually occur. If communication is lost, then <br /> Failure the tandem pump operation will not work properly. <br /> Pressure Detects the presence of the pressure transducer by monitoring the <br /> Transducer Failure signal. If the CPT Controller senses an abnormal voltage <br /> (without Leak sustained for 15 seconds, it indicates a fault condition. If leak <br /> Detection enabled) detection is disabled, the detection of the failed pressure <br /> transducer stops the control loop from running and will default the <br /> controller to run at a fixed frequency. <br /> } <br /> Chapter 5:Service and Repair 5-6 ARE260-240 Rev.A ♦ 6/97 <br />