My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1997-2002
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
J
>
JOE POMBO
>
2430
>
2300 - Underground Storage Tank Program
>
PR0506796
>
COMPLIANCE INFO_1997-2002
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/12/2021 4:13:51 PM
Creation date
6/23/2020 6:57:47 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1997-2002
RECORD_ID
PR0506796
PE
2361
FACILITY_ID
FA0007634
FACILITY_NAME
ARCO AM PM #82602*
STREET_NUMBER
2430
STREET_NAME
JOE POMBO
STREET_TYPE
PKWY
City
TRACY
Zip
95376
APN
214-020-200-000
CURRENT_STATUS
01
SITE_LOCATION
2430 JOE POMBO PKWY
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0506796_2430 JOE POMBO_1997-2002.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
420
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
provides 24-hour, automatic leak detection without tank <br /> shutdown. No lost business. No lost operating time. <br /> Leading-Edge Business Management Features <br /> Y The TLS-350 takes business management a step <br /> s beyond normal fuel inventory management.The SiteFax <br /> option provides auto-dial fax capability, letting you send <br /> up to 16 different reports to up to 8 separate fax ma- <br /> ® chines on a programmable schedule and fax alarm <br /> ' - r messages instantaneously.The Graphic Remote Display <br /> option lets the operator view all inventory,alarm and <br /> system status information without leaving the counter or <br /> office unattended. <br /> k�-- <br /> The optional fuel manager software available for the <br /> �44 TLS-350 allows you to track average daily fuel usage, <br /> predict the days of remaining inventory,and improve <br /> TQM `�l delivery scheduling. <br /> ► Modular design meets current bt rsiness and By utilizing Remote ControlTM Veeder-Roots new tank <br /> regulatory requirements, with expansion management software, all inventory management and <br /> capabilities for future needs. environmental compliance can be easily centralized on <br /> ► Integrated solution for centralized, single- a personal'computer in one location. <br /> system site monitoring. The use of these time and money saving options extend <br /> your investment in the TLS-350 beyond environmental <br /> ► Programmable leak test features. compliance requirements, improving your bottom line. <br /> ►2-line,24-character-per-line liquid crystal System Capabilities <br /> display and 12-button keyboard step the ► Continuous inventory monitoring. <br /> operator through simple programming ►Fast,0.1 GPH in-tank leak detection for up to 8 tanks. <br /> and Operation functions. ► CSLD option for continuous 24-hour leak detection. <br /> ►Line leak detection for up to 8 lines. <br /> With its modular design,the TLS-350 lets you choose the ►SiteFax auto-dial fax capability. <br /> exact set of compliance and fuel management features you ►Graphic Remote Display option. <br /> need today.As regulatory requirements and your business ►4SITE advanced technology sensor compatibility. <br /> needs change,the flexible TLS-350 platform allows you to ►Interstitial and piping sump leak sensing for up <br /> add new features tomorrow.A safe investment.A smart to 64 sensors. <br /> decision. ► Vapor and groundwater monitoring for up to 40 wells. <br /> Leading-Edge Leak Detection Technology <br /> ► External inputs. <br /> The TLS-350 has defined the industry standard for tank ► Relay outputs. <br /> monitoring systems with:advanced magnetostrictive probe ► Programmable alarms. <br /> technologies offering 0.2 GPH monthly monitoring and 0.1 ►Data communications. <br /> GPH volumetric tank testing; accurate, automatic electronic ► All third-party tested.All proven in the field. <br /> line leak detection;and,4srrEAdvanced Technology Emergency Generator Applications <br /> Sensors and a complete line of standard leak sensors to ► Selectable via programming. <br /> monitor double-wall tanks,containment sumps, and wet ► One system handles mix of standard and <br /> and dry wells. emergency generator tanks. <br /> Plus, for 24-hour stations and high-volume operations, ► Records generator activity. <br /> Continuous Statistical Leak Detection (CSLD), the most ► Complete inventory reports before and after <br /> advanced leak detection technology available today, generator operation. <br /> There's Profit Beyond Compliance. With Veeder-Root. <br />
The URL can be used to link to this page
Your browser does not support the video tag.