My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1997-2002
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
J
>
JOE POMBO
>
2430
>
2300 - Underground Storage Tank Program
>
PR0506796
>
COMPLIANCE INFO_1997-2002
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/12/2021 4:13:51 PM
Creation date
6/23/2020 6:57:47 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1997-2002
RECORD_ID
PR0506796
PE
2361
FACILITY_ID
FA0007634
FACILITY_NAME
ARCO AM PM #82602*
STREET_NUMBER
2430
STREET_NAME
JOE POMBO
STREET_TYPE
PKWY
City
TRACY
Zip
95376
APN
214-020-200-000
CURRENT_STATUS
01
SITE_LOCATION
2430 JOE POMBO PKWY
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0506796_2430 JOE POMBO_1997-2002.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
420
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
-,t-- <br /> Fittings , Adapters: bell x NPT male' Flange stub ends' <br /> Adapters:bell x NPT female2 Isolation bushings' <br /> Adapters:spigot x NPT female2 Nipples2 <br /> Adapters:spigot x NPT male2 Reducer bushings' <br /> 45° Elbows' Repair couplings' <br /> 900 Elbows' Sleeve couplings2 <br /> End caps' Tees' <br /> Flange rings' Dispenser pan penetration fittings' <br /> 1) Indicates molded fitting. <br /> 2) Indicates filament-wound fitting. <br /> 3) Other fittings available without UL listing. <br /> Typical pipe dimensions Nominal Pipe Pipe Wall Thickness Unit Pipe <br /> and Weights Pipe Size OD' ID Total Structural Volume Weight <br /> (in) (mm) (in) (mm) (in) (mm) (n) (mm) (n) (mm) (gal/ft) (I/m) (Ib/ft) (kg/m) <br /> 2 50 2.37 60 2.21 56 0.080 2.0 0.060 1.5 0.20 2.5 0.47 3.5 <br /> 3 80 3.50 89 3.32 84 0.085 2.2 0.065 1.6 0.45 5.6 0.72 5.2 <br /> 4 100 4.50 115 4.33 110 0.087 2.2 0.070 1.8 0.77 9.6 1.00 7.2 <br /> 6 150 6.63 168 6.39 162 0.120 3.1 0.100 2.5 1.67 20.7 2.10 15.2 <br /> 1) Typical outside diameters of 2 throj gh 6-inch pipe are within API,ASTM and ANSI fiberglass and <br /> steel pipe dimensions. <br /> Typical pipe performance Nominal Pressure Ultimate Internal Ultimate <br /> Pipe Size Rating' Pressure' Collapse Pressure2 <br /> (in) (mm) (psig) (MPa) (psig) (MPa) (psig) (MPa) <br /> 2 50 300 2.07 3200 22.1 153 1.05 <br /> 3 80 200 1.38 2400 16.5 90 0.62 <br /> 4 100 175 1.21 2000 13.8 39 0.27 <br /> 6 150 175 1.21. 2000 13.8 38 0.26 <br /> 1) At 150°F(66"C). <br /> 2) At 80°F(27°C).For continuous service do not exceed 75%of these values. <br /> Fittings pressure For dimensions of fittings,consult Ameron publication DUALov 3000/L FITTINGS <br /> performance DIMENSIONS, FP266.Pressure ratings of fittings without UL listing are available on <br /> request. <br /> Nominal <br /> Pipe Size All fittings' <br /> (in) (mm) (psig) (MPa) <br /> 2 50 250 1.72 <br /> 3 80 150 1.03 <br /> 4 100 125 0.86 <br /> 6 150 100 0.69 <br /> 1) Some fittings have higher pressure <br /> ratings than shown. <br /> 2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.