My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2003-2005
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
J
>
JOE POMBO
>
2430
>
2300 - Underground Storage Tank Program
>
PR0506796
>
COMPLIANCE INFO_2003-2005
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/24/2021 1:15:55 PM
Creation date
6/23/2020 6:57:48 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2003-2005
RECORD_ID
PR0506796
PE
2361
FACILITY_ID
FA0007634
FACILITY_NAME
ARCO AM PM #82602*
STREET_NUMBER
2430
STREET_NAME
JOE POMBO
STREET_TYPE
PKWY
City
TRACY
Zip
95376
APN
214-020-200-000
CURRENT_STATUS
01
SITE_LOCATION
2430 JOE POMBO PKWY
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0506796_2430 JOE POMBO_2003-2005.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
442
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
0 <br /> PLLD Site Prep and Installation Guide PLLD Interface Module <br /> 0 <br /> Note: Throughout this manual, when mentioning any cable or wire being used for PLLD transducer-to-console wiring,it <br /> will be referring to shielded cable. <br /> Alternate Wiring Type-When Approved by the Local Authority Having Jurisdiction! <br /> #22 AWG stranded copper,shielded cable(REQUIRED)and manufactured with a material suitable for the environment, <br /> such as Belden 88761.Wiring to be installed as a Class l circuit with the following provisions: <br /> • Wire run must not exceed 750 feet to meet intrinsic safety requirments, <br /> • Capacitance does not exceed 100 pF/ft, <br /> • Inductance does not exceed 0.2µH/ft. <br /> Splices <br /> Veeder-Root recommends that no splices be made in the wire run between a PLLD transducer junction box and the <br /> console.Each splice degrades signal strength and could result in poor system performance. <br /> PLLD Interface Module <br /> 1. Run conduit from the Intrinsically Safe bay of the console to each STP manhole with a PLLD transducer installed. <br /> There are knockouts for 3/4-inch, 1-inch or 1'/4-inch conduit in the console's enclosure. When deciding on the size and <br /> number of conduits required,consider the number of wires entering the console. <br /> 2. Install a weatherproof electrical junction box with a Basketed cover for each PLLD transducer. <br /> IMPORTANT!The junction box in the STP manhole must be within 4-feet of the PLLD transducer.The junction box <br /> interior must be a minimum of 16 cubic inches with 1/2-inch NPT threads. <br /> 3. Pull shielded cable designed for use in the presence of gasoline and oil,from each PLLD transducer to the console <br /> (Figure 3-1). <br /> 4. Use gasketing or sealing compound at each entry to the junction box to keep it waterproof.Use a watertight cord grip <br /> at the PLLD transducer cable entry into the junction box. <br /> 5. IMPORTANT! Seal the conduit between the console and the PLLD transducer junction box within the submersible <br /> pump manhole and the boundary where they pass from a Class I,Division I area into a nonhazardous area in <br /> accordance with the National Electrical Code(NFPA 70)and the Automotive and Marine Service Station Code <br /> (NFPA 30A). <br /> 3-2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.