a <br /> Installation Guide Example VSFC Installations <br /> RequirementsInstallation <br /> The Red Jacket Variable Speed Flow Controller(VSFC) is only to be used with CPT or VSFC pumps <br /> P200020-2, AGP20OT20-2 or P20OT20-2 (Standard,Quantum or RED JACKET models). <br /> The VSFC monitors pump output line pressure to ensure a constant flow to each nozzle in the fuel line, <br /> regardless of the number of nozzles in use at any time. Depending on observed line pressure,the VSFC varies <br /> the pump's fundamental frequency and power to increase or decrease the pump's rotational speed and hence <br /> its output pressure.When multiple tanks are connected to a common product line,one tank is designated the <br /> master tank and additional tanks are designated as slaves. A VSFC unit is required for each tank in a multiple <br /> tank system, but only the master tank requires a pressure transducer. <br /> The Red Jacket VSFC can be installed stand alone or in conjunction with a TLS-350 Console. If the TLS-350 <br /> Console also performs pressurized line leak detection,the VSFC independently controls the pump to maintain <br /> desired nozzle flow rate, and also operates the pump for line leak testing as directed by the console. <br /> Locating the VSFC Unit <br /> AWARNING <br /> Explosive vapors or flammable liquids could be present near locations where fuels <br /> are stored or being dispensed. <br /> The VSFC unit is not explosion proof.Do not install this device in a volatile, <br /> combustible,or explosive atmosphere. <br /> An explosion or fire resulting in serious injury or death,property loss and <br /> equipment damage could occur if the VSFC unit is installed in a volatile, <br /> combustible or explosive atmosphere(Class I,Division 1 or 2). <br /> Select a mounting location on the inside of any building.The VSFC unit must be protected from severe <br /> vibration,extremes in temperature and humidity, rain,and other conditions that could harm computerized <br /> electronic equipment.The unit's operating temperature range is 32 to 113°F(0 to 45°C), and its storage <br /> temperature range is-40 to+167°F(-40 to+75°C). <br /> The mounting surface should be strong enough to support the unit's weight of 9 pounds. You should also <br /> consider wall space for routing the power wiring conduits and comm wiring conduits that must be connected <br /> to the unit. <br /> Example VSFC Installations <br /> • Figure 2 illustrates stand alone VSFC installations with separate conduit for pressure and pump control <br /> wirings. <br /> • Figure 3 illustrates VSFC/TLS-350 installations with separate conduit for pressure and pump control <br /> wiring. <br /> • Table 1 illustrates the required kits and check valves for PLLD operation, by pump type. <br /> 4 <br />