Laserfiche WebLink
SAN JOAQUIN COUNTY ENVIR0N1ffiN1AL HEALTH DEPARTMENT <br /> 304 E.Weber Ave.,Third Floor• Stockton,CA 95202-2708 • Phone(209)468-3420 <br /> Donna Heran,RF-H.S.,Director <br /> ENVIRONMENTAL HEALTH <br /> SAN JOAQUIN COUNTY CERTIFIED LNIFIED PROGRAM AGENCY <br /> PERMIT TO OPERATE <br /> Program Permit Permit <br /> Record ID Number Program Code and Description Valid <br /> PRO518016 PT0011812 2220-SMALL QUANTITY HAZARDOUS WASTE GENERATOR FACILITY 1/1/2004 To 12/31/2004 <br /> Hazardous Waste Generator Program: <br /> In order to maintain the permit to operate,Hazardous Waste Generators shall comply with California Health and Safety Code, Div.20,Chap.6.5,Art.2-13, <br /> Sec.25100 et seq,_and Title 22,California Code of Regulations,Chap._20:_____ --------------------------------------._ <br /> PR0506796 2300-UNDERGROUND STORAGE TANK FACILITY 1/1/2004 To 12/31/2004 <br /> Underground Storage Tank Program: <br /> California Health and Safety Code,Div.20,Chap.6.7 and Title 23,California Code of Regulations,Chap_16._ ____ <br /> - ------------------------------------------- ---- <br /> P/E Tank# Tank Record ID Permit# Capacity Conte-.= Permit Status System Type Leak Detection <br /> 2360 3 390005067960506799 PT0009077 10,000 REGULAR I.X-E-kD_D Active,billable DOUBLE WALLED Continuous Interstitial Monitoring <br /> 2360 2 390005067960506798 PT0009076 10,000 REGULAR UN!EADcD Active, billable DOUBLE WALLED Continuous Interstitial Monitoring <br /> 2362 1 390005067960506797 PT0009075 20,000 REGULAR UN _AD.D Active,billable DOUBLE WALLED Continuous Interstitial Monitoring <br /> Underground Storage Tank Permit Conditions <br /> 1) The Permit to Operate will become void if Annual Permit Fees and Service Fees are not paid=d'or the UST system(s)fails to remain in compliance with these Permit Conditions. <br /> 2) In order to maintain the operating permit,the owner and operator shall comply with the H&S Ccs Div.13,Chap.6.7 and 6.75;and CCR,Title 23,Chap. 16 and 18,as well as any conditions <br /> established by San Joaquin County. <br /> 3) If the Tank Operator(s)is different from the Tank Owner,or if the Permit to Operate is issued x.a penon other than the owner or operator of the tan:<,the Permittee shall ensure that both <br /> the Tank Owner and tank Operator receive a copy of the permit. <br /> 4) Written Monitoring Procedures and an Emergency Response Plan must be approved by the Emi--ental Health Department(EHD)and are considererd UST Permit Conditions. The approved <br /> monitoring,response,and plot plans shall be maintained onsite with the permit. <br /> 5) The Permittee shall comply with the monitoring procedures referenced in this permit. <br /> 6) The Permittee shall perform testing and preventive maintenance on all leak detection monito-ag eqw ment annually,or more frequently if specified by the equipment manufacturer,and <br /> provide documentation of such servicing to this office. <br /> 7) In the event of a spill,leak,or other unauthorized release,the Permitee shall comply with the-wuirements of Title 23 CCR,Chap.16,Art.5,and the approved Emergency Response Plan. <br /> 8) Written records of all monitoring performed shall be maintained on-site by the operator and be vailabie for inspection for a period of at least three years from the date the monitoring was <br /> performed. <br /> 9) The EHD shall be notified of any change in ownership or operation of the UST system within 30 ?s of such change. <br /> 10) Upon any change in equipment,design or operation of the UST system(including change in .:i contents or usage),the Permit to Operate will be subject to review,modification or <br /> 11) LS)St Atglbn,repair and/or removal permits are required from the EHD prior to any change,repay r removal of UST system equipment. <br /> 12) The Permittee shall submit an annual report documenting compliance with the UST Pemtit Con&xrs witan 30 days of the date of the issuance of this permit <br /> 13) This Permit to Operate shall not be considered permission to violate any laws,ordinances or>--mutes of any other Federal,State or Local agency. <br /> 14) A"Conditional"Permit may be revoked if corrections specified on the inspection report are not completed by the date(s) indicated. <br /> PERMITS TO OPERATE are NOT TRANSFERABLE <br /> and may be SUSPENDED or REVOKED for cause. <br /> PERMIT(s)Valid only for: BP WEST COAST PRODUCTS LLC <br /> Tank Owner: BP WEST COAST PRODUCERS LLC <br /> THIS FORM MUST BE DISPLAYED CONSPICUOUSLY ON THE PREMISES <br /> Regulated Facility: ARCO AM/PM FACILITY#6347* Facility ID FA0007634 <br /> 2430 JOE POMBO PKWY Account ID AR0012817 <br /> TRACY, CA 95376 Issued 4/1/2004 <br /> Billing Address: ATTN : ENVIRONMENTAL COMPLIANCE DE-PT <br /> ARCO AM/PM FACILITY #6347* <br /> PO BOX 6038 <br /> ARTESIA, CA 90702-6038 <br /> 7023.rpt <br />