Laserfiche WebLink
0 <br /> San Joaquin County <br /> oultv <br /> DIRECTOR <br /> Environmental Health Department <br /> Donna Heran,REHS <br /> 600 East Main Street <br /> Sto <br /> PROGRAM COORDINATORS' California 95202-3029 <br /> Robert McClellon,REHS <br /> Jeff Carruesco,REHS,RDI <br /> Website: www.sjgov.org1ehd Kasey Foley, REHS <br /> Phone: (209)468-3420 Linda Turkafte,REHS <br /> January 19, 2010 Fax: (209)464-0138 <br /> Robert Barnhart <br /> Reliable Petroleum Services Inc. <br /> 11930 Horsehoe Road <br /> Oakdale, CA 95361 <br /> Re: Arco AMPM#82602 SR0061805 <br /> 2430 Joe Pombo Parkway, Tracy 95377 <br /> The San Joaquin County Environmental Health Department(EHD) has completed the review of <br /> the application for a permit to replace and install the Veeder-Root PLLD Series 8484 on the 91 <br /> tank of the underground storage tank(UST) system at the above noted address. The permit <br /> has been approved with the following conditions: <br /> 1. Contact the local fire department and the San Joaquin Valley Air Pollution Control <br /> District for any applicable permits and requirements. <br /> 2. Any changes in information and scope of work must be submitted to EHD for approval <br /> prior to commencing work. All new addenda supersede the previous ones. <br /> 3. Contact Thuy Tran at(209)468-8257 to arrange the following inspection appointments <br /> (a 48-hour notice is required for inspection appointments). Please be aware that <br /> inspections for emergency work must be scheduled within five days of permit approval. <br /> a. Leak detector test: Leak detector must be tested to confirm that the device can <br /> detect a leak of 3 gallons per hour at 10 psi. <br /> Please be aware that the facility cannot operate the 91 UST system tank prior to <br /> the EHD inspection and approval. <br /> 4. Qualified service technicians must possess or work under the direct and personal <br /> supervision of an individual physically present at the work site who possesses all of the <br /> following: <br /> a. One of several permissible valid, current contractors licenses issued by the <br /> Contractors State License Board (may be issued to the installation company), or a <br /> Tank Testers license issued to the individual by the State Water Board, and <br /> b. A valid, current California UST Service Technician certificate issued by the <br /> International Code Council (ICC), and <br /> c. A valid, current certificate of training from the manufactureqs)of the component(s) <br /> being tested, repaired, or serviced. <br />