Laserfiche WebLink
MONARING SYSTEM CERT1F#ATI 0VR087,,-`�r/�'`'For Use By All Jurisdictions Within the State of California <br /> Authority Cited.-Chapter 6 7,Health and Safe Code,tyChapter 16,Division 3, Title 23CaliforniaAUyojRg,4ati <br /> This form must be used to document testing and servicing of monitoring equipment. A separate cc ification o <br /> rennd for each <br /> monitoring system control panel by the technician who performs the work. A copy of this form must be provided I rator. <br /> The owner/operator must submit a copy of this form to the local agency regulating UST systems within '(fILW/ <br /> i 30 days of test a . <br /> A. General Information <br /> 1IRMICE6, <br /> Facility Name: ARCO AM PM#82602 Bldg.No.: <br /> Site Address: 2430 Joe Pombo parkway City: Tracy CA Zip: 95377 <br /> Facility Contact Person: Raqjeet Singh Contact Phone No.: f209 -401A4 <br /> Make/Model of Monitoring System: Veeder Root TLS-350 ) 579 <br /> Date of Testing/Servicing: 1012112009 <br /> B. Inventory of Equipment Tested/Certified <br /> Check the a2propriate boxes to indicates ecifle!Suipment insmtcd/serviced: <br /> Tank ID: TI: Master Tank in T2: Slave <br /> M <br /> TIn-Tank Gauging Probe. Model: 847390-109 in-Tank—Gauging Probe. Model: 847390-109 <br /> Annular Space or Vault Sensor. Model: 794390-409 Annular Space or Vault Sensor. Model: 794390-409 <br /> Piping Sump/Trench Sensor(s). Model: 794380-323 Piping Sump/Trench Sensor(s). Model: 794380-323 <br /> ®Fill Sump Sensor(s). Model: 794380-323 Fill Sump Sensor(s). Model: 794380-323 <br /> El Mechanical Line Leak Detector. Model: ❑Mechanical Line Leak Detector. Model: <br /> 0 Electronic Line Leak Detector. Model: 8484 0 Electronic Line Leak Detector. Model: 8484 <br /> n Tank Overfill/High-Level Sensor. Model: El Tank Overfill/High-Level Sensor. Model: <br /> El Other(specify equipment type and model in Scction E on Page 2). n Other(specify equipment type and model in Section E on Page 2). <br /> Tank ID: T3: 91 Tank ID: <br /> In-Tank Gauging Probe. Model: 847390-I09 [I In-Tank Gauging Probe. Model: <br /> Annular Space or Vault Sensor. Model: 7943 09 F-1 Annular Space or Vault Sensor. Model: <br /> Piping Sump/Trench Sensor(s). Model: 794380.323 [1 Piping Sump/Trench Sensor(s). Model: <br /> Fill Sump Sensor(s). Model: 794380-323 El Fill Sump Sensor(s). Model: <br /> El Mechanical Line Leak Detector. Model: n Mechanical Line Leak Detector. Model: <br /> Electronic Line Leak Detector. Model: 8484 0 Electronic Line Leak Detector. Model: <br /> ❑Tank Overfill/High-Level Sensor. Model: El Tank Overfill/High-Level Sensor. Model: <br /> El Other(specify equipment type and model in Section E on Page 2). El Other(specify equipment type and model in Section E on Page 2). <br /> Dispenser ID: 1/2 Dispenser ID: 3/4 <br /> 0 Dispenser Containment Sensor(s). Model: 794380-323 0 Dispenser Containment Sensor(s). Model: 794380-323 <br /> N Shear Valve(s). 0 Shear Valve(s). <br /> C]Dispenser Containment Float(s)and Chain(s). El Dispenser Containment Float(s)and Chain(s). <br /> NENMNEW� <br /> Dispenser ID: 616 Dispenser ID: 718 <br /> Dispenser Containment Sensor(s). Model: 79M0-323 0 Dispenser Containment Sensor(s). Model: 794380-323 <br /> Shear Valve(s). 21 Shear Valve(s). <br /> Dispenser Containment Float(s)and Chain(s). El Dispenser Containment Float(s)and Chain(s). <br /> go <br /> Dispenser ID: 9/10 Dispenser ID; 11/12 <br /> Dispenser Containment Sensor(s). Model: 794380-323 0 Dispenser Containment Sensor(s). Model: 794380-323 <br /> Shear Valve(s). 0 Shear Valve(s). <br /> 0 Dispenser Containment Float(s)and Chain(s). 0 Dispenser Containment Float(s)and Chain(s), <br /> *If the facility contains more tanks or dispensers,copy this form. Include information for every tank and dispenser at the facility. <br /> C. Certification-I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' <br /> guidelines. Attached to this Certification is information (e.g. manufacturers' checklists) necessary to verify that this information is <br /> correct and a Plot Plan showing the layout of monitoring uipment. For any eq ment capable of generating such reports,I have also <br /> attached a copy of the report;(check all that apply): System set-up 2 Alarm history rt <br /> Technician Name(print): Robert Barnhart Signature:A,�-LO47, <br /> Certification No.: 835969 License.No.: 8d3706 L, <br /> Testing Company Name: Reliable Petroleum Service Inc. Phone No.:(209) 845-8586 <br /> Testing Company Address: 521 Branding Iron Street, Oakdale CA 96361 Date of Testing/Servicing: 10/21/2009 <br /> Page 1 of 4 <br /> UN-036-1/4 www.unidoes.org Rev.01/17/Q8 <br />