My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2006-2012
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
J
>
JOE POMBO
>
2430
>
2300 - Underground Storage Tank Program
>
PR0506796
>
COMPLIANCE INFO_2006-2012
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/24/2021 2:56:37 PM
Creation date
6/23/2020 6:57:49 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2006-2012
RECORD_ID
PR0506796
PE
2361
FACILITY_ID
FA0007634
FACILITY_NAME
ARCO AM PM #82602*
STREET_NUMBER
2430
STREET_NAME
JOE POMBO
STREET_TYPE
PKWY
City
TRACY
Zip
95376
APN
214-020-200-000
CURRENT_STATUS
01
SITE_LOCATION
2430 JOE POMBO PKWY
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0506796_2430 JOE POMBO_2006-2012.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
377
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
e t <br /> MON14MNG SYSTEMCIFI TION <br /> For Use By All Jurisdictions Within the State of California <br /> Authority Cited: Chapter 6.7, Health and Safety Code;Chapter 16, Division 3, Title 23, California Code of Re ,{tgns- <br /> This form must be used to document testing and servicing of monitoring equipment. A separate certification or re - ��sd. c 1 f'bf'each <br /> monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank system owner/operator. <br /> The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date CT 1 1 X008 <br /> A. General Information - <br /> Facility Name: ARCO AM PM#82602 <br /> Site Address: 2430 Joe Pombo Parkway City: Tracy Zip: 95376 <br /> Facility Contact Person: Ranjeet Singh Contact Phone No.: (209) 579-4014 <br /> Make/Model of Monitoring System: Veeder Root TLS-350 Date of Testing/Servicing: 10/9/2008 <br /> B. Inventory of Equipment Tested/Certified <br /> Check the appropriate boxes to indicatespecific a ui ment ins eeted/serviced: <br /> Tank ID: T1: 87 Master Tank iD: T2: 87 Slave <br /> Z in-Tank Gauging Probe. Model: 847390-109 ®In-Tank Gauging Probe. Model: 847390409 <br /> Z Annular Space or Vault Sensor. Model: 794390-409 ®Annular Space or Vault Sensor. Model: 794390-409 <br /> Z Piping Sump/Trench Sensor(s). Model: 794380-323 ®Piping Sump/Trench Sensor(s)_ Model: 794380-323 <br /> Z Fill Sump Sensor(s). Model: 794380-323 Z Fill Sump Sensor(s). Model: 794380-323 <br /> ❑Mechanical Line Leak Detector. Model: ❑Mechanical Line Leak Detector. Model: <br /> Z Electronic Line Leak Detector. Model: 8484 ®Electronic Line Leak Detector. Model: 8484 <br /> ❑Tank Overfill/High-Level Sensor. Model: AN @ 90% ❑Tank Overfill/High-Level Sensor. Model: AN @ 90% <br /> ❑Other(specify equipment type and model in Section E on Page 2). ❑Other(specify equipment type and model in Section E on Page 2). <br /> Tank ID: T3: 91 Tank ID: <br /> ®In-Tank Gauging Probe. Model: 847390-109 ❑In-Tank Gauging Probe. Model: <br /> Z Annular Space or Vault Sensor. Model: 794390-409 ❑Annular Space or Vault Sensor. Model: <br /> Z Piping Sump/Trench Sensor(s). Model: 794380-323 ❑Piping Sump/Trench Sensor(s)- Model: <br /> Z Fill Sump Sensor(s). Model: 794380-323 ❑Fill Sump Sensor(s). Model: <br /> ❑Mechanical Line Leak Detector. Model: ❑Mechanical Line Leak Detector. Model: <br /> Z Electronic Line Leak Detector. Model: 8484 ❑Electronic Line Leak Detector. Model: <br /> El Tank Overfill/High-Level Sensor. Model: AN @ 90% ❑Tank Overfill/High-Level Sensor. Model: <br /> ❑Other(specify equipment type and model in Section E on Page 2). ❑Other(specify equipment type and model in Section E on Page 2). <br /> Dispenser ID: 112 Dispenser ID: 3 14 <br /> Z Dispenser Containment Sensor(s). Model: 794380-323 Z Dispenser Containment Sensor(s). Model: 794380-323 <br /> Z Shear Valve(s). Z Shear Valve(s). <br /> ❑Dispenser Containment Float(s)and Chain(s). ❑Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: 516 Dispenser ID: 718 <br /> ®Dispenser Containment Sensor(s). Model: 794380-323 ®Dispenser Containment Sensor(s). Model- 794380-323 <br /> ®Shear Valve(s). Z Shear Valve(s). <br /> ❑Dispenser Containment Float(s)and Chain(s). ❑Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: 9110 Dispenser ID: 11 112 <br /> Z Dispenser Containment Sensor(s). Model: 794380-323 Z Dispenser Containment Sensor(s). Model: 794380-323 <br /> Z Shear Valve(s). Z Shear Valve(s). <br /> ❑Dispenser Containment Float(s)and Chain(s). ❑Dispenser Containment Float(s)and Chain(s). <br /> *If the facility contains more tanks or dispensers,copy this form. Include information for every tank and dispenser at the facility. <br /> C. Certification -I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' <br /> guidelines. Attached to this Certification is information (e.g. manufacturers' checklists) necessary to verify that this information is <br /> correct and a Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating such reports,I have also <br /> attached a copy of the report;(check all that apply): ®System set-up Z Alarm history report <br /> ' / <br /> Technician Name(print): Guadalupe Sanchez S* tui <br /> Certification No.: A30138 License.No.: 883706 <br /> Testing Company Name: Reliable Petroleum Services Inc. Phone No.:(209) 845-8586 <br /> Testing Company Address: 521 Branding Iron St. Oakdale Ca.95361 Date of Testing/Servicing: 10/9/2008 <br /> Page 1 of 4 <br /> Rev(2/08) <br />
The URL can be used to link to this page
Your browser does not support the video tag.