My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2006-2012
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
J
>
JOE POMBO
>
2430
>
2300 - Underground Storage Tank Program
>
PR0506796
>
COMPLIANCE INFO_2006-2012
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/24/2021 2:56:37 PM
Creation date
6/23/2020 6:57:49 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2006-2012
RECORD_ID
PR0506796
PE
2361
FACILITY_ID
FA0007634
FACILITY_NAME
ARCO AM PM #82602*
STREET_NUMBER
2430
STREET_NAME
JOE POMBO
STREET_TYPE
PKWY
City
TRACY
Zip
95376
APN
214-020-200-000
CURRENT_STATUS
01
SITE_LOCATION
2430 JOE POMBO PKWY
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0506796_2430 JOE POMBO_2006-2012.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
377
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Monitoring System Certification <br />Site Address: 2430 JOE POMBO PARKWAY <br />@ WEST GRANTLINE ROAD <br />F. In -Tank Gauging / SIR Equipment <br />11 <br />Date of Testing/Service: 10/05/2006 <br />❑ Check this box if tank gauging is used only for inventory control. <br />❑ Check this box if no tank gauging or SIR equipment is installed. <br />This section must be completed if in -tank gauging equipment is used to perform leak detection monitoring. <br />Complete the following checklist: <br />QYes <br />❑ No <br />Has all input wiring been inspected for proper entry and termination, including testing for ground faults? <br />Yes <br />❑ No <br />Were all tank gauging probes visually inspected for damage and residue buildup? <br />El Yes <br />❑ No <br />Was accuracy of system product level readings tested? <br />E]Yes <br />❑No <br />Was accuracy of system water level readings tested? <br />x Yes <br />❑ No = <br />Were all probes reinstalled properly? <br />El Yes <br />❑ No <br />Were all items on the equipment manufacturers' maintenance checklist completed? <br />- In the Section H, below, describe how and when these deficiencles were or will be corrected. <br />G. Line Leak Detectors (LLD) <br />Complete the following checklist: <br />❑ Check this box if LLDs are not installed. <br />❑x Yes <br />❑ No ` <br />❑ N/A <br />For equipment start-up or annual equipment certification, was a leak simulated to verify LLD performance? <br />(Check all that apply) Simulated leak rate: x❑ 3 g.p.h ❑ 0.1 g.p.h ❑0.2 g.p.h <br />x Yes <br />❑ No x <br />Were all LLDs confirmed operational and accurate within regulatory requirements? <br />x Yes <br />❑ No • <br />Was the testing apparatus properly calibrated? <br />❑ Yes <br />❑ No <br />❑x N/A <br />For mechanical LLDs, does the LLD restrict product flow if it detects a leak? <br />Q Yes <br />❑No rt <br />❑ N/A <br />For electronic LLDs, does the turbine automatically shut off if the LLD detects a leak? <br />M Yes <br />❑No " <br />❑ N/A <br />For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system is disabled or disconnected? <br />x❑ Yes <br />❑No ^ <br />F-1 N/A <br />For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system malfunctions or fails a test? <br />x❑ Yes <br />❑No <br />N/A <br />For electronic LLDs, have all accessible wiring connections been visually inspected? <br />MYes <br />I❑No • <br />Were all items on the equipment manufacturers' maintenance checklist completed? <br />In the Jection H, Deiow, oescrioe now ana wnen tnese aenciencies were or will be correctea. <br />H. Comments: <br />Page 3 of 3 Based on CA form dated 03/01 <br />
The URL can be used to link to this page
Your browser does not support the video tag.