My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2006-2012
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
J
>
JOE POMBO
>
2430
>
2300 - Underground Storage Tank Program
>
PR0506796
>
COMPLIANCE INFO_2006-2012
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/24/2021 2:56:37 PM
Creation date
6/23/2020 6:57:49 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2006-2012
RECORD_ID
PR0506796
PE
2361
FACILITY_ID
FA0007634
FACILITY_NAME
ARCO AM PM #82602*
STREET_NUMBER
2430
STREET_NAME
JOE POMBO
STREET_TYPE
PKWY
City
TRACY
Zip
95376
APN
214-020-200-000
CURRENT_STATUS
01
SITE_LOCATION
2430 JOE POMBO PKWY
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0506796_2430 JOE POMBO_2006-2012.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
377
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
11 <br />3. PhAna Leak Detection Monitoring Equipment <br />Monitoring Method <br />Manufacturer <br />Model <br />Monitoring Frequency <br />® Sump leak sensors connected to <br />Veeder Root <br />794380-208 <br />continuous monitoring system <br />Specify type: <br />Veeder Root <br />794380-208 <br />Continuous <br />❑ Discriminating <br />Continuous <br />® Non -discriminating <br />❑ Mechanical line leak detectors with <br />programmed leak threshold of three <br />❑ Daily <br />❑ Other: <br />❑ No under -dispenser containment <br />gallons per hour <br />❑ Other (specify): <br />® Electronic line leak detectors with <br />RED JACKET <br />CPT <br />programmed leak threshold of : <br />VAPORLESS (91 tank) <br />LD2000 (91 tank) <br />❑ 0.1 gph ❑0.2 gph 03 qph <br />❑ Line integrity testing by: <br />❑ Electronic line leak detector is <br />equipped to conduct line tightness <br />❑ Annually <br />testing <br />❑ Other: <br />❑ Third party testing <br />® Not required <br />❑ Other (Specify): <br />4. Dispenser Leak Detection Monitorinq Equipment <br />MonitoringMethod <br />Manufacturer <br />Model <br />Monitoring Frequency <br />❑ Mechanical float in dispenser <br />containment <br />® Electronic leak sensor in dispenser <br />Veeder Root <br />794380-208 <br />containment: <br />Continuous <br />❑ Discriminating <br />® Non -discriminating <br />❑ Visual inspection <br />❑ Daily <br />❑ Other: <br />❑ No under -dispenser containment <br />❑ Other (specify): <br />5. Positive Shutdown Gapaointles <br />❑ S stem does not have positive shutdown capabilities <br />❑ Individual dispenser shutdown will occur whenever release is sensed in under -dispenser containment <br />® Automatic pump shut off will occur whenever: <br />® Release is sensed in turbine sump <br />® Release is sensed in primary piping <br />® Release is sensed at dispenser <br />® Monitoring system is disconnected or fails in any way (fail safe) <br />❑ Other (specify): <br />6. Secondary Containment Testin <br />_❑ Secondary containment is not tested <br />® In the State of California, secondary containment systems installed on or after January 1, 2001, shall be tested upon installation, <br />six months after installation, and every 36 months thereafter. Secondary containment systems installed prior to January 1, 2001, <br />shall be tested by January 1, 2003, and every 36 months thereafter. <br />7. Annual Equipment Certification/Testing <br />® Annually <br />❑ Other (specify): <br />E <br />
The URL can be used to link to this page
Your browser does not support the video tag.