My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1997-2003
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
G
>
GRANT LINE
>
2360
>
2300 - Underground Storage Tank Program
>
PR0507204
>
COMPLIANCE INFO_1997-2003
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/11/2021 3:34:59 PM
Creation date
6/23/2020 6:57:55 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1997-2003
RECORD_ID
PR0507204
PE
2361
FACILITY_ID
FA0007735
FACILITY_NAME
7-ELEVEN INC #32262
STREET_NUMBER
2360
Direction
W
STREET_NAME
GRANT LINE
STREET_TYPE
RD
City
TRACY
Zip
95376
APN
23819001
CURRENT_STATUS
01
SITE_LOCATION
2360 W GRANT LINE RD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0507204_2360 W GRANT LINE_1997-2003.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
255
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
INDIVIDUAL TANK INFORMATION AND TEST RESULTS <br /> r Tankmilogy <br /> TEST DATE:07/08/03 8900 SHOAL CREEK,BUILDING 200 WORK ORDER NUMBER2227161 <br /> CLIENT:7-ELEVEN, INC. AUSTIN,TEXAS 78757(512)451-6334 SITE:7-ELEVEN #32262 <br /> TANK INFORMATION <br /> Tank ID: #1 1 Tank manifolded: No Bottom to top fill in inches: 137.0 <br /> Product: REG UNLEAD Vent manifolded: No Bottom to grade in inches: 147.0 <br /> Capacity in gallons: 14,781 Vapor recovery manifolded: YES Fill pipe length in inches: 47.0 <br /> Diameter in inches: 90.00 Overfill protection: YES Fill pipe diameter in inches: 4.0 <br /> Length in inches: 543 Overspill protection: YES Stage I vapor recovery: DUAL <br /> Material: DW FISERG Installed: ATG Stage II vapor recovery: ASSIST <br /> CP installed on: <br /> COMMENTS <br /> TANK TEST RESULTS Test Method:VacuTect LEAK DETECTOR TEST RESULTS Test method: FTA <br /> Start(in) End(in) <br /> Dipped Water Level: 0.00 0.00 New/passed Failed/replaced New/passed Failed/replaced <br /> Dipped Product Level: 43.00 43.00 L.D.#1 L.D.#1 L.D.#2 L.D.#2 <br /> Probe Water Level: -0.026 -0.026 Make: RED JACKET VAPORLESS <br /> Ingress Detected: Water N Bubble N UllageN Model: Fx1V LD2000 <br /> Test time: 08.23-10:00 S/N• 20503-9588 01051572 <br /> Inclinometer reading: 0.00 Open time in sec: 5.00 <br /> VacuTect Test Type: Single tank Holding psi: 26 NOT <br /> Resiliency in ml: <br /> VacuTect Probe Entry Point: Fill Test leak rate ml/m: 189.0 TESTED <br /> Pressure Set Point: -0.50 Metering psi: 12 <br /> Tank water level in inches: 0.00 Calib. leak in gph: 3.00 3.00 <br /> Water table depth in inches: 120.00 Results: PASS FAIL <br /> Determined by(method): MONTR WELL <br /> Result: PASS <br /> COMMENTS <br /> COMMENTS <br /> TANKS ARE D/W WITH WET ANNULARTS <br /> LINE TEST RESULTS Test type: TLD-1 <br /> LINE A B C D <br /> Material: GEO FLEX <br /> Diameter(in): 1.5 <br /> Length(ft): 150.0 <br /> Test psi: 50 <br /> Bleedback cc: 0 <br /> Test time(min): 60 NOT NOT NOT <br /> Start time: 11:20 TESTED TESTED TESTED <br /> End time: 12:20 <br /> Final gph: 0.003 <br /> Result: PASS <br /> Pump type: PRESSURE <br /> Pump make: FE PETRO <br /> COMMENTS Impact Valves Operational: YES <br /> Draft 07/09/2003 10:34 MSHAW <br />
The URL can be used to link to this page
Your browser does not support the video tag.