My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1997-2003
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
G
>
GRANT LINE
>
2360
>
2300 - Underground Storage Tank Program
>
PR0507204
>
COMPLIANCE INFO_1997-2003
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/11/2021 3:34:59 PM
Creation date
6/23/2020 6:57:55 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1997-2003
RECORD_ID
PR0507204
PE
2361
FACILITY_ID
FA0007735
FACILITY_NAME
7-ELEVEN INC #32262
STREET_NUMBER
2360
Direction
W
STREET_NAME
GRANT LINE
STREET_TYPE
RD
City
TRACY
Zip
95376
APN
23819001
CURRENT_STATUS
01
SITE_LOCATION
2360 W GRANT LINE RD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0507204_2360 W GRANT LINE_1997-2003.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
255
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
INDIVIDUAF TANK INFORMATION AND MST RESULTS <br /> J'ip Tanknology <br /> TEST DATE:05/22/01 8900 SHOAL CREEK,BUILDING 200 WORK ORDER NUMBER2216856 <br /> CLIENT:7-ELEVEN, INC. AUSTIN,TEXAS 78757(512)451-6334 SITE:7-ELEVEN #32262 <br /> N One= <br /> Tank ID: #2 2 Tank manifolded: No Bottom to top fill in inches: 134.0 <br /> Product: MIDGRADE Vent manifolded: No Bottom to grade in inches: 142.0 <br /> Capacity in gallons: 10,000 Vapor recovery manifolded: yES Fill pipe length in inches: 39.0 <br /> Diameter in inches: 95.00 Overfill protection:yES Fill pipe diameter in inches: 4.0 <br /> Length in inches: 330 Overspill protection:yES Stage I vapor recovery: DUAL <br /> Material: DW STEEL Installed: ATG Stage 11 vapor recovery: ASSIST <br /> CP installed on: <br /> COMMENTS <br /> . .......... ...... <br /> gh <br /> Stan(in) End(in) New/passed Failed/replaced New/passed Failed/replaced <br /> Dipped Water Level: L.D.#1 L.D.#1 L.D.#2 L.D.#2 <br /> Dipped Product Level: Make: vApoRLEss <br /> Probe Water Level: Model: LD2000 <br /> Ingress Detected: Water Bubble Ullage S/N: 72633 <br /> Test time: Open time in sec: 9.00 <br /> Inclinometer reading: Holding psi: 28 <br /> VacuTect Test Type: NOT Resiliency cc: 460 NOT <br /> VacuTect Probe Entry Point: TESTED Test leak rate ml/m: 189.0 TESTED <br /> Pressure Set Point: Metering psi: 10 <br /> Tank water level in inches: Calib. leak in gph: 3.00 <br /> Water table depth in inches: Results: PASS <br /> Determined by(method): <br /> Result: COMMENTS <br /> COMMENTS <br /> ne L <br /> .......... <br /> Material: ENviRoE= <br /> Impact Valves Operational:yES Diameter(in): 2.0 <br /> Length(ft): 150.0 <br /> COMMENTS Test psi: 50 <br /> Bleedback cc: 780 <br /> Test time(min): 30 <br /> Test 1: Start time: 12:05 <br /> Finish psi: 49 NOT NOT NOT <br /> Vol change cc: 7 <br /> Test 2: Start time: 12:16 TESTED TESTED TESTED <br /> Finish psi: 50 <br /> Vol change cc: 0 <br /> Test 3:Start time: 12:27 <br /> Finish psi: so <br /> Vol change cc: 0 <br /> Final gph: 0.004 <br /> Result: PASS <br /> Pump type: PRESSURE <br /> Pump make: FE PETRO <br /> Printed 05/24/2001 09:22 CCHAPA <br />
The URL can be used to link to this page
Your browser does not support the video tag.