My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1997-2003
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
G
>
GRANT LINE
>
2360
>
2300 - Underground Storage Tank Program
>
PR0507204
>
COMPLIANCE INFO_1997-2003
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/11/2021 3:34:59 PM
Creation date
6/23/2020 6:57:55 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1997-2003
RECORD_ID
PR0507204
PE
2361
FACILITY_ID
FA0007735
FACILITY_NAME
7-ELEVEN INC #32262
STREET_NUMBER
2360
Direction
W
STREET_NAME
GRANT LINE
STREET_TYPE
RD
City
TRACY
Zip
95376
APN
23819001
CURRENT_STATUS
01
SITE_LOCATION
2360 W GRANT LINE RD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0507204_2360 W GRANT LINE_1997-2003.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
255
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
---19 <br /> IMA INFORMATION AND AT RESULTS <br /> Y <br /> 8900 SHOAL CREEK,BUILDING 200 <br /> TEST DATE: 06/03/99 AUSTIN,TEXAS 78757(512)451-6334 WORK ORDER NUMBER: 2208865 <br /> CLIENT: 7-ELEVEN, INC. SITE: 7-ELEVEN #32262 <br /> g <br /> Tank ID: 87/RUL I Tank manifolded: No Bottom to top fill in inches: 3.34.0 <br /> Product: REG UNLEAD Vent manifolded: NO Bottom to grade in inches: 142.0 <br /> Capacity in gallons: 12,000 Vapor recovery manifolded: YES Fill pipe length in inches: 39.0 <br /> Diameter in inches: 95.00 Overfill protection: YES Fill pipe diameter in inches: 4.0 <br /> Length in inches: 396 Overspill protection: YES Stage I vapor recovery: DUAL <br /> Material: DW STEEL Installed: ATG Stage 11 vapor recovery: ASSIST <br /> CP installed on: <br /> COMMENTS <br /> PSI at tank bottom: New/passed Failed/replaced New/passed Failed/replaced <br /> Fluid level in inches: L.D.#1 L.D.#1 L.D.#2 L.D.#2 <br /> UFT/OFT: Make: VAPORLESS <br /> Fluid volume in gallons: Model: LD2000 <br /> Tank water level in inches: S/N: <br /> Test time: NOT Open time in sec: 4.00 <br /> Number of thermisters: TESTED Holding psi: 18 NOT <br /> Specific gravity: Resiliency cc: 280 TESTED <br /> Water table depth in inches: Test leak rate ml/m: 189.0 <br /> Determined by(method): Metering psi: 10 <br /> Leak rate in gph: Calib. leak in gph: 3.00 <br /> Result: Results: PASS <br /> COMMENTS COMMENTS <br /> Test time: Material: ENVIROFLEX <br /> Ullage volume: Diameter(in): 2.0 <br /> Ullage pressure: Length (ft): 150.0 <br /> Results: Test psi: 5o <br /> Bleedback cc: 140 <br /> DATA FOR UTS-4T ONLY: Test time (min): 30 <br /> Test 1:Start time: 14:20 <br /> Time of test 1: Finish psi: so NOT NOT NOT <br /> Temperature: NOT Vol change cc: o TESTED TESTED TESTED <br /> Test 2:Start time: 14:30 <br /> Flow rate(cfh): TESTED Finish psi: 50 <br /> Time of test 2: Vol change cc: o <br /> Test 3:Start time: 14:40 <br /> Temperature: Finish psi: 4e <br /> Flow rate(cfh): Vol change cc: 13 <br /> Time of test 3: Final gph: 0.007 <br /> Temperature: Result: PASS <br /> Flow rate(cfh): Pump type: PRESSURE <br /> COMMENTS Pump make: FE PETRO <br /> COMMENTS Impact Valves Operational: YES <br /> Printed 06/16/1999 08:42 MSHAW <br />
The URL can be used to link to this page
Your browser does not support the video tag.