2300 - Underground Storage Tank Program
>
PR0507204
>
COMPLIANCE INFO_1997-2003
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/11/2021 3:34:59 PM
Creation date
6/23/2020 6:57:55 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1997-2003
RECORD_ID
PR0507204
PE
2361
FACILITY_ID
FA0007735
FACILITY_NAME
7-ELEVEN INC #32262
STREET_NUMBER
2360
Direction
W
STREET_NAME
GRANT LINE
STREET_TYPE
RD
City
TRACY
Zip
95376
APN
23819001
CURRENT_STATUS
01
SITE_LOCATION
2360 W GRANT LINE RD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0507204_2360 W GRANT LINE_1997-2003.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
255
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
INDIVIDUAL ANK/LINE/LEAK DETECTOR TEWkEPORT <br /> TEST DATE: 07/29/98 WORK ORDER NUMBER: 2205552 <br /> CLIENT: THE SOUTHLAND SITE: 7-11 <br /> Tank ID:92/PUL 3 Material:Dw STEEL Bottom to top fill in inches: 134.0 <br /> Product:PREMIuM Tank manifolded:No Bottom to grade fill in inches: 142.0 <br /> Capacity in gallons: 1o,000 Vent manifolded:No Fill pipe length in inches: 39.0 <br /> Diameter in inches: 95.00 Vapor recovery manifolded:SCEs Fill pipe diameter in inches: 4.0 <br /> Length in inches: 330 Impact Valves Operational: y Stage I vapor recovery: DUAL <br /> Tank age(years): Overfill protection: SCEs Stage II vapor recovery: ASSIST <br /> Fuel pure rating: Overspill protection: yEs Installed: ATG <br /> COMMENTS CP installed on: <br /> i 10 1111: <br /> ir.) Ena jin) New/passed Failed/replaced New/passed Failed/replaced <br /> Dipped Water Level: 0.00 0.00 L.D.#1 L.D.#1 L.D.#2 L.D.#2 <br /> Dipped Product Level: 22.00 22.00 Make: <br /> Probe Water Level: 0.000 0.000 Model: <br /> Ingress Detected: Water N Bubble N UllageN S/N: <br /> Test time: 17:11-20:11 Open time in sec: <br /> VacuTect Test Type: Multiple Holding psi: <br /> VacuTect Probe Entry Point: Fill Resiliancy cc: <br /> Pressure Set Point: -1.00 Test leak rate ml/m: <br /> Tank water level in inches: 0.00 Metering psi: <br /> Water table depth in inches: Calib. leak in gph: <br /> Determined by(method): No WELL Results: <br /> Result: PASS <br /> COMMENTS COMMENTS <br /> MAG PROBE DW DRY ANNULER <br /> Material: ENviROFLEX <br /> Diameter(in): 2.0 <br /> Length (ft): 150.0 <br /> Test psi: 50 <br /> Bleedback cc: 700 <br /> Test time(min): 30 <br /> Test 1:Start time: 17:49 <br /> Finish psi: 50 <br /> Vol change cc: 6 <br /> Test 2:Start time: 17:59 <br /> Finish psi: so <br /> Vol change cc: 3 <br /> Test 3:Start time: 20:09 <br /> Finish psi: 50 <br /> Vol change cc: o <br /> Final gph: 0.005 <br /> Result: PASS <br /> Pump type: PRESSURE <br /> COMMENTS Pump make: FE PETRO <br /> 8900 SHOAL CREEK,BUILDING 200,AUSTIN,TEXAS 78757(512)451-6334 Printed 08/06/98 12:08 MSHAW <br />