Laserfiche WebLink
IED PROGRAM CONSOLIDATED F <br /> UNDERGROUND STORAGE TANK <br /> MONITORING PLAN - (Pae 1 of 2) <br /> TYPE OF ACTION ❑ 1.NEW PLAN ® 2.CHANGE OF INFORMATION ago-l. <br /> PLAN TYPE ® 1.MONITORING IS IDENTICAL FOR ALL USTs AT THIS FACILITY. 490-2 <br /> (Check one item only) ❑ 2.THIS PLAN COVERS ONLY THE FOLLOWING UST SYSTEM(S): <br /> ITX ORMATION' <br /> FACILITY ID#(Agency Use Only) t• <br /> BUSINESS NAME(Same as Facility Name or DBA) 7-Eleven # 32262 3 <br /> BUSINESS SITE ADDRESS <br /> 2360 Grantline 103• CITY Tracy 104. <br /> II. EC2 NT TE�TN PREVENT NTE .-_. <br /> Testing,preventive maintenance,and calibration of monitoring equipment(e.g.,sensors,probes,line leak detectors,etc.)must be performed at the frequency specified <br /> by the equipment_manufacturers'instructions,or annually,whichever is more frequent.Such work must be performed b ualified ersonnel.[z3 ccR§2632,2634,263x,2641) <br /> y..............................................................................9.....................................................................................p................. <br /> Y...q...........................I?............................-................................................................................................. <br /> MONITORING EQUIPMENT IS SERVICED ® 1.ANNUALLY ❑ 99.OTHER(Specify): 490-30-. <br /> Q ( P �')� 490-3b. <br /> ,r .. TO L(ICATIONS '_ <br /> ❑ 1.NEW SITE PLOT PLAN/MAP SUBMITTED WITH THIS PLAN ® 2.SITE PLOT PLAN/MAP PREVIOUSLY SUBMITTED [23 CCR§2632,26341 490-4. <br /> coo <br /> _n usING THE P©LLQ <br /> ® 1.CONTINUOUS ELECTRONIC TANK MONITORING OF ANNULAR(INTERSTITIAL)SPACE(S)OR SECONDARY CONTAINMENT VAULT(S) 49-5. <br /> WITH AUDIBLE AND VISUAL ALARMS.[23 CCR§2632,26341 <br /> SECONDARY CONTAINMENT IS: ❑ a.DRY ® b.LIQUID FILLED ❑ c.PRESSURIZED ❑ d.UNDER VACUUM 490-6. <br /> PANEL MANUFACTURER: Veeder-Root 490-7. MODEL#: TLS-350 490-8. <br /> LEAK SENSOR MANUFACTURER: Veeder-Root 490-9' MODEL#(s): 794390-302 490-10. <br /> ......................................................... .......................................................... <br /> ........ <br /> 2.AUTOMATIC TANK GAUGING(ATG)SYSTEM USED TO MONITOR SINGLE WALL TANK(S).[23 CCR§26431 490-11. <br /> PANEL MANUFACTURER: 490-12• MODEL#: 490-13. <br /> IN-TANK PROBE MANUFACTURER: 490-14. MODEL#(S): 490-15. <br /> LEAK TEST FREQUENCY: ❑ a.CONTINUOUS ❑ b.DAILY/NIGHTLY ❑ c.WEEKLY 490-16. <br /> ❑ d.MONTHLY ❑ e.OTHER(Specify): <br /> 490-17. <br /> PROGRAMMED TESTS: ❑ a.0.1 h. ❑ b.0.2 h. ❑ c.OTHER(Specify): 490-18. <br /> g.p.h. g•P• ago-19. <br /> ............................................................................................................................................................................................................................................................................................................................................................................................................................ <br /> 490.20:.... <br /> ❑ 3.MONTHLY STATISTICAL INVENTORY RECONCILIATION[23 CCR§2646.11 <br /> ................................................................................................................................................................................................................................................................................................................................ . <br /> . . . .................................................................................................................................................................................................................................................1...... <br /> ❑ 4.WEEKLY MANUAL TANK GAUGING(MTG)[23 CCR§26451 TESTING PERIOD: ❑ a.36 HOURS ❑ b.60 HOURS 490-z1. <br /> 490-22. <br /> ❑ 5.TANK INTEGRITY TESTING PER[23 CCR§2643.11 490-23. <br /> TEST FREQUENCY: ❑ a.ANNUALLY ❑ b.BIENNIALLY ❑ c.OTHER(Specify) a�4 024. <br /> .................................................................................................................................................................................................................................................................................................................................................................................................... <br /> ......................................... <br /> ® <br /> 99.OTHER(Specify): Overfill protection-Flapper 490-26. <br /> 490-27. <br /> x PIPE MU O � 5 G Ft3LLQ� _ i _ <br /> �.. _ ` ' . <br /> ® 1.CONTINUOUS MONITORING OF PIPE/PIPING SUMP(S)AND OTHER SECONDARY CONTAINMENT WITH AUDIBLE&VISUAL ALARMS. 490-28. <br /> [23CCR SECONDARY CONTAINMENT IS: ® a.DRY El b.LIQUID FILLED 11c.PRESSURIZED ❑ d.UNDER VACUUM 490-29. <br /> §263PANEL MANUFACTURER:Veeder-Root 490-30. MODEL#: TLS-350 490-31. <br /> LEAK SENSOR MANUFACTURER: Veeder-Root 490-32. MODEL#(s): 794380-352 490-33. <br /> PIPING LEAK ALARM TRIGGERS AUTOMATIC PUMP(i.e.,TURBINE)SHUTDOWN. ® a.YES ❑ b.NO 490-34. <br /> FAILURE/DISCONNECTION OF THE MONITORING SYSTEM TRIGGERS AUTOMATIC PUMP SHUTDOWN. ® a.YES ❑ b.NO 490-35. <br /> ........................................................................................................................................................................................................................................................................................................................................................................ . <br /> ® 2.MECHANICAL LINE LEAK DETECTOR(MLLD)THAT ROUTINELY PERFORMS 3.0 g.p.h.LEAK TESTS AND RESTRICTS OR SHUTS OFF 490-36- <br /> PRODUCT FLOW WHEN A LEAK IS DETECTED.[23 CCR§26361 <br /> MLLD MANUFACTURER(S):Va orless 490-37. MODEL#(s): LD2000 49-38. <br /> .......................................................................................................................I.............................. ....................................................... .............................. <br /> ❑ 3.ELECTRONIC LINE LEAK DETECTOR(ELLD)THAT ROUTINELY PERFORMS 3.0 g.p.h.LEAK TESTS.[23 CCR§26361 490-39. <br /> ELLD MANUFACTURER(S): 490.40. MODEL#(S): 490-41. <br /> PROGRAMMED IN LINE LEAK TEST: ❑ a.MINIMUM MONTHLY 0.2 g.p.h. ❑ b.MINIMUM ANNUAL 0.1 g.p.h. 490-42. <br /> ELLD DETECTION OF A PIPING LEAK TRIGGERS AUTOMATIC PUMP SHUTDOWN. ❑ a.YES ❑ b.NO 490-43. <br /> ELLD FAILURE/DISCONNECTION TRIGGERS AUTOMATIC PUMP SHUTDOWN. ❑ a.YES ❑ b.NO 490-41- <br /> ...... ............ ..............­­................. <br /> 90-40-........................................................................................................................ .....................................................................................................................................................................................................................-.............................................................................................................................................................-.................. <br /> .... <br /> ❑ 4.PIPE INTEGRITY TESTING. 490-45. <br /> TEST FREQUENCY: ❑ a.ANNUALLY ❑ b.EVERY 3 YEARS ® c.OTHER(Specify) SB989 eve 36 mo. 490-46. <br /> ( p fY) x . .. <br /> ❑ 5.VISUAL PIPE MONITORING. 49048. <br /> FREQUENCY: ❑ a.DAILY ❑ b.WEEKLY ❑ c.MIN.MONTHLY&EACH TIME SYSTEM OPERATED* 490-49. <br /> ............................._................_.........................................._.......................................................................................................................................................... .'.Allowed for monitorin of unburied emer enc enerator fuel i in oral r HSC§25281.5(b)(3) <br /> ❑ 6.SUCTION PIPING MEETS EXEMPTION CRITERIA.[23 CCR§2636(a)(3)] 490-50. <br /> ..........................................................................._........................................._..................._........................ <br /> ❑ 7.NO REGULATED PIPING PER HEALTH AND SAFETY CODE,DIVISION 20,CHAPTER 6.7 IS CONNECTED TO THE TANK SYSTEM. 490-51. <br /> ........................................._. <br /> . ................................................................................................................................................................................... <br /> ❑ <br /> 99.OTHER(Specify) 49490-s2. <br /> -53. <br /> UPCF UST-D(12/2007)-1/4 www.unidocs.org <br />