My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2009-2012
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
G
>
GRANT LINE
>
2360
>
2300 - Underground Storage Tank Program
>
PR0507204
>
COMPLIANCE INFO_2009-2012
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/29/2024 11:25:26 AM
Creation date
6/23/2020 6:58:13 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2009-2012
RECORD_ID
PR0507204
PE
2361
FACILITY_ID
FA0007735
FACILITY_NAME
7-ELEVEN INC #32262
STREET_NUMBER
2360
Direction
W
STREET_NAME
GRANT LINE
STREET_TYPE
RD
City
TRACY
Zip
95376
APN
23819001
CURRENT_STATUS
01
SITE_LOCATION
2360 W GRANT LINE RD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0507204_2360 W GRANT LINE_2009-2012.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
422
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1 0 <br /> SWRCB,January 2002 Page 2 of 2 <br /> 7. UNDER—DISPENSER CONTAINMENT (UDC) TESTING <br /> Test Method Developed By: r UDC Manufacturer Industry Standard r Professional Engineer <br /> r Other(Specify) <br /> Test Method Used By: r Pressure r- vacuum G Hydrostatic <br /> r Other(Specify) <br /> Test Equipment Used: VPLT Equipment Resolution: <br /> 'IUDC#9/10 UC# UDC# <br /> A . ...... <br /> UDC Manufacturer: 48 48 <br /> UDC Material: <br /> Fiberglass Fiberglass <br /> UDC Depth: 29.00 29.00 <br /> Height from UDC Bottom to Top of <br /> Highest Piping Penetration: 10.00 10.00 <br /> Height from UDC Bottom to Lowest <br /> Electrical Penetration; 2.00 2.00 <br /> Condition of UDC prior to testing: good good <br /> Portion of UDC Testedl 31 31 i <br /> Does turbine shut down when UDC <br /> sensor detects liquid(both product and rYes r No NA r Yes r No ro NA j r Yes r Nor NA r Yes r No NA <br /> water)?. <br /> Turbine shutdown response time 00:00:00 sec 00:00:00 sec sec sec <br /> Is system programmed for fail-safe rYes r No NA r Yes r No NA r Yes r No NA r Yes r No 0 NA <br /> shutdown?* <br /> Was fail-safe verified to be operational?* rYes r NoG NA r Yes r No GV NA r Yes r Nor NA r Yes r No 0 NA <br /> Wait time between applying <br /> 1 5 min 5 min min min <br /> pressure/vacuum/water and starting test I I <br /> Test Start Time: 18:19:00 17:03:00 <br /> Initial Reading(RI): 0.00000 in. 0.00000in. <br /> ............. <br /> Test End Time: 18:34:00 17:18:00 <br /> Final Reading(RF): -0.00040 in. -0.00080 In. <br /> Test Duration: 15 min 15 min <br /> ................ <br /> Change In Reading(RF-RI) <br /> -0.00040 in. -0.00080 In. <br /> ........... <br /> Pass/Fail Threshold or Criteria: i i +/- +/- <br /> 0.00200 0.00200 <br /> 77k <br /> R �y <br /> R <br /> M" <br /> 0 <br /> ":Pa P " <br /> Test'"Uli�i <br /> was sensor removed r testing? ro Yes r No r NA G Yes r Nor NA Yes r No� NA r Yes r No 117W NA <br /> Was sensor properly replaced andG Yes C- No NA re Yes r No NA r Yes r No 01 NA r Yes r�' No M NA <br /> verified functional after testing? <br /> L <br /> Comments?(include information on repairs made prior to testing,and recommended follow-up for failed tests) <br /> If the entire depth of the UDC is not tested, specify how much was tested. If the answer to any of the questions indicated with an asterisk(*) is?NO?or?NA?,the <br /> entire UDC must be tested. <br />
The URL can be used to link to this page
Your browser does not support the video tag.