My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2016-2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
G
>
GRANT LINE
>
2360
>
2300 - Underground Storage Tank Program
>
PR0507204
>
COMPLIANCE INFO_2016-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/29/2024 11:45:34 AM
Creation date
6/23/2020 6:58:22 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2016-2018
RECORD_ID
PR0507204
PE
2361
FACILITY_ID
FA0007735
FACILITY_NAME
7-ELEVEN INC #32262
STREET_NUMBER
2360
Direction
W
STREET_NAME
GRANT LINE
STREET_TYPE
RD
City
TRACY
Zip
95376
APN
23819001
CURRENT_STATUS
01
SITE_LOCATION
2360 W GRANT LINE RD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0507204_2360 W GRANT LINE_2016-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
222
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
RECEIVED <br />SWRCB, January 2006 <br />Spill Bucket Testing Report Form`>> <br />This form is intended for use by contractors performing annual testing of UST spill containment structures. The comp e�f� <br />° <br />printouts from tests (if applicable), should be provided to the facility owner/operator for submittal to the local re ul�'� <br />1. FACILITY INFORMATION <br />Facility Name: 7 -ELEVEN #32262, MKT 2368 (N-3940-1 I Date of Testing: 3/3/2016 <br />Facility Address: 2360 W GRANTLINE I-205 OFF RAMP, TRACY, CA 95376 <br />Facility Contact: CHANDRA Phone: 209-830-9917 <br />Date Local Agency Was Notified of Testing: <br />Name of Local Agency Inspector (if present during testing): <br />2. TESTING CONTRACTOR INFORMATION <br />Company Name: TANKNOLOGY INC. <br />Technician Conducting Test: Nicolas Poblano <br />Credentialst : Ml CSLB Contractor 17" ICC Service Tech. M SWRCB Tank Tester F! Other (Specify) <br />License Number(s): <br />3. SPILL BUCKET TESTING INFORMATION <br />Test Method Used By: Hydrostatic r7. Vacuum Other <br />Test Equipment Used: VPLT Equipment Resolution: <br />0.00001 in. <br />Identify Spill Bucket (By Tank <br />Number, Stored Product, etc.) <br />Spill Box # Tank T4 RUL . <br />REG UNLEAD - Fill 1- <br />Direct -Grade level in <br />containment sump <br />= Spill Box # Tank T5 MUL <br />MIDGRADE - Fill 1 - Direct <br />-Grade level in <br />containment sump <br />Spill Box # Tank T6 PUL <br />PREMIUM - Fill 1 - Direct - <br />Grade level in containment <br />sump <br />Spill Box <br />Bucket Installation Type: <br />Direct Bury <br />l+ Contained in Sump <br />r Direct Bury <br />ro Contained in Sump <br />f 7 Direct Bury <br />Io Contained in Sump <br />r Direct Bury <br />C Contained in Sump <br />Bucket Diameter: <br />10.50 <br />10.50 <br />10.50 <br />Bucket Depth: <br />16.00 <br />16.00 <br />13.25 <br />Wait time between applying <br />vacuum/water and start of test <br />5 min <br />5 min <br />5 min <br />min <br />Test Start Time (TI): <br />09:48:00 <br />12:00:00 <br />11:13:00 <br />Initial Reading (Rt): <br />14.50 in. <br />14.50 in. <br />12.25 in. <br />Test End Time(TF): <br />09:48:00 <br />12:10:00 <br />12:13:00 <br />Final Reading (RF): <br />14.50 in. <br />13.00 in. <br />12.25 in. <br />Test Duration(TF—Tl): <br />1 hr <br />10 min <br />1 hr <br />Change in Reading (RF—RI) : <br />0.00 in. <br />-1.50 in. <br />0.00 in. <br />Pass/Fail Threshold or Criteria: <br />+/-0.00 <br />+/-0.00 <br />+/-0.0077 <br />Test Result:, <br />Pass <br />Fail <br />Pass <br />Comments - (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />Spill bucked 89 grade failed after inspection of bucket found that jack screw assembly was damaged. needs to be repaired and retested. <br />CERTIFICATION OF TECHNICIAN RESPONSIBLE FOR CONDUCTING THIS TESTING <br />I hereby certify that all the information contained in this report is true, accurate, and in full compliance with legal requirements. <br />Technician's Signature <br />Date: 3/3/2016 <br />I State laws and regulations do not currently require testing to be performed by a qualified contractor. However, local requirements may be more stringent. <br />WO: 2325965 <br />
The URL can be used to link to this page
Your browser does not support the video tag.