Laserfiche WebLink
Appendix VI <br /> (Copies of Monitoring System Certification form and UST Monitoring Plot Plan available at http://www.swrcb.ca.gov.) <br /> MONITORING SYSTEM CERTIFICATION <br /> For Use By All Jurisdictions Within the State of California <br /> Authority Cited:Chapter 6.7,Health and Safety Code;Chapter 16,Division 3, Title 23, California Code of <br /> Regulations <br /> This form must be used to document testing and servicing of monitoring equipment.A separate certification or report must be prepared for each monitoring <br /> system control panel by the technician who performs the work.A copy of this form must be provided to the tank system owner/operator.The <br /> owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br /> A.General Information <br /> Facility Name: 7-ELEVEN#32262,MKT 2368(N-3940-1 Bldg. No.: <br /> Site Address: 2360 W GRANTLINEI-205 OFF RAMP City: TRACY Zip: 95376 <br /> Facility Contact Person: CHANDRA Contact Phone No.: 209-830-9917 <br /> Make/Model of Monitoring System: Veeder Root TLS-35OR Date of Testing/Servicing: 2/16/2018 <br /> B.Inventory of Equipment Tested/Certified <br /> Check the appropriate boxes to indicatespecific a ui ment inspected serviced: <br /> Tank ID: T4 RUL-REG UNLEAD Tank ID: T6 PUL-PREMIUM <br /> P In-Tank Gauging Probe. Model: 847390-109 PF In-Tank Gauging Probe. Model: 847390-109 <br /> Annular Space or Vault Sensor. Model: 794380-303 P Annular Space or Vault Sensor. Model: 794380-303 <br /> rV Piping Sump/Trench Sensor(s). Model: 794380-352 rN7 Piping Sump/Trench Sensor(s). Model: 794380-352 <br /> Fill Sump Sensor(s). Model: 794380-208 rqo� Fill Sump Sensor(s). Model: 794380-208 <br /> Mechanical Line Leak Detector. Model: Vaporless LD-2000 r Mechanical Line Leak Detector. Model: Vaporless LD-2000 <br /> Electronic Line Leak Detector. Model: rElectronic Line Leak Detector. Model: <br /> Tank Overfill/High-Level Sensor.Model: Flapper rV Tank Overfill/High-Level Sensor.Model: Flapper <br /> Other(specify equipment a and model in Section E on Pae 2). , Others ecify equipment a and model in Section E on Pae 2). <br /> Tank ID: T5 MUL-MIDGRADE Tank ID: <br /> In-Tank Gauging Probe. Model: 847390-109 r In-Tank Gauging Probe. Model: <br /> +f' Annular Space or Vault Sensor, Model: 794380-303 Annular Space or Vault Sensor. Model: <br /> P' Piping Sump/Trench Sensor(s). Model: 794380-352 Piping Sump/Trench Sensor(s). Model: <br /> rf; Fill Sump Sensor(s). Model: 794380-208 Fill Sump Sensor(s). Model: <br /> �; Mechanical Line Leak Detector. Model: Vaporless LD-2000 Mechanical Line Leak Detector. Model: <br /> Electronic Line Leak Detector. Model: Electronic Line Leak Detector. Model: <br /> r Tank Overfill/High-Level Sensor.Model: Flapper r Tank Overfill/High-Level Sensor.Model: <br /> Other(specify equipment a and model in Section E on Pae 2). r,, Other(specify equipment a and model in Section E on Pae 2). <br /> Dispenser 1/2 Dispenser 7/8 <br /> ID: ID: <br /> Dispenser Containment Sensor(s).Model: 847990-002 r Dispenser Containment Sensor(s).Model: 847990-002 <br /> (i/ Shear Valve(s). P Shear Valve(s). <br /> Dispenser Containment Float(s)and Chain(s). Dispenser Containment Float(s)and Chain(s). <br /> Dispenser 3/4 Dispenser 9/10 <br /> ID: ID: <br /> 17 Dispenser Containment Sensor(s).Model: 847990-002 ry Dispenser Containment Sensor(s).Model: 847990-002 <br /> Shear Valve(s). rqF Shear Valve(s). <br /> Dispenser Containment Float(s)and Chain(s). Dispenser Containment Float(s)and Chain(s). <br /> Dispenser 5/6 Dispenser 11/12 <br /> ID: ID: <br /> r Dispenser Containment Sensor(s).Model: 847990-002 Dispenser Containment Sensor(s).Model: 847990-002 <br /> Shear Valve(s). r7 Shear Valve(s). <br /> Dispenser Containment Float(s)and Chain(s). 1_� Dispenser Containment Float(s)and Chain(s). <br /> *If the facility contains more tanks or dispensers,copy this form.Include information for every tank and dispenser at the facility. <br /> C.Certification-I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers'guidelines.Attached to <br /> this Certification is information(e.g.manufacturers'checklists)necessary to verify that this information is correct and a Plot Plan showing the layout of <br /> monitoring equipment.For any equipment capable of generating such reports,I have also attached a copy of the report; (check all that apply):r System set- <br /> up P Alarm history report <br /> Technician Name(print): Brent Bowen Signature: <br /> Certification No.: B42815 License. No.: 743160 Class'A' <br /> Testing Company Name: Tanknology Phone No.: (800)800-4633 <br /> Testing Company Address: 11000 N.MoPac Expressway Suite 500 Date of Testing/Servicing: 2/16/2018 <br /> Monitoring System Certification Page 1 of 3 12/07 <br />