Laserfiche WebLink
F. In -Tank Gauging / SIR Equipment: Check this box if tank gauging is used only for inventory control <br />Check this box if no tank gauging or SIR equipment is iIP14 R <br />ltir;: Z V Ui7 <br />This section must be completed if in -tank gauging equipment is used to perform leak detection monitoring. <br />Complete the following checklist: <br />Yes <br />No* <br />Has all input wiring been inspected for proper entry and termination, including testing for ground faults? <br />+r Yes <br />No* <br />Were all tank gauging probes visually inspected for damage and residue buildup? <br />Yes <br />' No* <br />Was accuracy of system product level readings tested? <br />Yes <br />No* <br />Was accuracy of system water level readings tested? <br />Yes <br />7 No* <br />Were all probes reinstalled properly? <br />•, Yes <br />No* <br />ere all items on the equipment manufacturer's maintenance checklist completed? <br />* In the Section H, below, describe how and when these deficiencies were or will be corrected. <br />G. Line Leak Detectors (LLD): r Check this box if LLDs are not installed. <br />Complete the following checklist: <br />Yes <br />7 No* <br />For equipment start-up or annual equipment certifications was a leak simulated to verify LLD performance? (Check all that <br />apply) S imulated leak rater 3 g.p.h.; r 0.1 g.p.h; 1 10.2 g.p.h. <br />N/A <br />Yes <br />No* <br />Were all LLDs confirmed operational and accurate within regulatory requirements? <br />+t Yes <br />No* <br />Was the testing apparatus properly calibrated? <br />4. Yes <br />No* <br />For mechanical LLDs, does the LLD restrict product Flow if it detects a leak? <br />N/A <br />_� Yes <br />No* <br />For electronic LLDs, does the turbine automatically shut off if the LLD detects a leak? <br />N/A <br />u Yes <br />17 No* <br />For electronic LLDs that are programmed for positive shut down, does the turbine automatically shut off if any portion of the <br />monitoring system is disabled or disconnected? <br />N/A <br />• Yes <br />"% No* <br />For electronic LLDs that are programmed for positive shut down, does the turbine automatically shut off if any portion of the <br />monitoring system malfunctions or fails a test? <br />N/A <br />•% Yes <br />"; No* <br />For electronic LLDs, have all accessible wiring connections been visually inspected? <br />N/A <br />Yes <br />"' No* <br />1were all items on the equipment manufacturer's maintenance checklist completed? <br />* In the Section H, below, describe how and when these deficiencies were or will be corrected. <br />Page 4 of 4 12/07 <br />