COMPLIANCE INFO_1998-2006
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
T
>
TRACY
>
755
>
2300 - Underground Storage Tank Program
>
PR0508090
>
COMPLIANCE INFO_1998-2006
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/29/2023 8:31:25 AM
Creation date
6/23/2020 6:58:26 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1998-2006
RECORD_ID
PR0508090
PE
2361
FACILITY_ID
FA0007938
FACILITY_NAME
CHEVRON #208117**
STREET_NUMBER
755
Direction
S
STREET_NAME
TRACY
STREET_TYPE
BLVD
City
TRACY
Zip
95376
APN
24202029
CURRENT_STATUS
01
SITE_LOCATION
755 S TRACY BLVD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0508090_755 S TRACY_1998-2006.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
427
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
TANK MONITORING <br />EQUIPMENT AT THIS FACILITY: Veeder-Root TLS -350 Series 8470 <br />The Underground storage tanks are monitored using an approved continuous electronic monitoring <br />system (see below). This system is able to detect the presence of a leak in the primary as well as <br />secondary containment through the use of an annular space and submerged sensor. If an alarm or failure <br />condition occurs, the Operator will call Chevron Maintenance Dispatch at 800-423-3528 immediately. The <br />Operator will then record the alarm condition on a log along with the investigative/corrective action steps <br />followed to resolve the situation. Response to the alarm condition will occur within 24 hours. <br />If the alarm condition is NOT the result of an equipment failure, then Chevron will repair the tank system <br />in accordance with all local and state requirements. If the alarm condition is the result of an equipment <br />failure, Chevron will repair the equipment as required and ensure that it is functioning properly. <br />MONITORING SYSTEM <br />INTERSTITIAL MONITOR: X LIQUID FLOAT SWITCH SENSOR <br />EQUIPMENT AT THIS FACILITY: Veeder-Root TLS -350 Annular Space Monitor Series 794390-409 <br />MAINTENANCE CONTRACTOR: Chevron Maintenance Dispatch <br />The Operator or a designated employee performs visual monitoring of the tank monitor alarm box daily. <br />Please see the attached site map for the location of all equipment and forms for keeping monitoring <br />records at the site. The Operator will also perform inventory reconciliation according to the procedure <br />outlined in the Inventory reconciliation section of this plan. <br />The electronic monitoring devices are maintained according to manufacturers recommendations. <br />Training will be given which includes information regarding: how to self test the electronic monitoring <br />equipment, what the equipment monitors, how to tell when the alarm goes off, how to perform inventory <br />reconciliation, record keeping requirements and procedures to follow in the event of alarm activation, <br />leak, suspected leak, or other emergency. All training is in accordance with the equipment manufacturer <br />recommendations. <br />See also "Chevron Leak Response Plan" <br />Chevron Emergency Information Center (CEIC)1-800-231-0623 <br />Chevron Maintenance Dispatch 1-800-423-3528 <br />3 <br />