My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1998-2006
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
T
>
TRACY
>
755
>
2300 - Underground Storage Tank Program
>
PR0508090
>
COMPLIANCE INFO_1998-2006
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/29/2023 8:31:25 AM
Creation date
6/23/2020 6:58:26 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1998-2006
RECORD_ID
PR0508090
PE
2361
FACILITY_ID
FA0007938
FACILITY_NAME
CHEVRON #208117**
STREET_NUMBER
755
Direction
S
STREET_NAME
TRACY
STREET_TYPE
BLVD
City
TRACY
Zip
95376
APN
24202029
CURRENT_STATUS
01
SITE_LOCATION
755 S TRACY BLVD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0508090_755 S TRACY_1998-2006.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
427
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
EQUIPMENT AT THIS FACILITY: Veeder-Root TLS -350 Series 8470 <br />The Underground storage tanks are monitored using an approved continuous electronic monitoring <br />system (see below). This system is able to detect the presence of a leak in the primary as well as <br />secondary containment through the use of an annular space and submerged sensor. If an alarm or <br />failure condition occurs, the Operator will call Chevron Maintenance Dispatch at 800-423-3528 <br />immediately. The Operator will then record the alarm condition on a log along with the <br />investigative/corrective action steps followed to resolve the situation. Response to the alarm <br />condition will occur within 24 hours. <br />If the alarm condition is NOT the result of an equipment failure, then Chevron will repair the tank <br />system in accordance with all local and state requirements. If the alarm condition is the result of an <br />equipment failure, Chevron will repair the equipment as required and ensure that it is functioning <br />properly. <br />MONITORING SYSTEM <br />INTERSTITIAL • • • FLOAT STT1TCAR• <br />EQUIPMENT AT THIS FACILITY: Veeder-Root TLS -350 Annular Space Monitor Series 794390-409 <br />MAINTENANCE CONTRACTOR: Chevo:Maintenance . <br />The Operator or a designated employee performs visual monitoring of the tank monitor alarm box <br />daily. Please see the attached site map for the location of all equipment and forms for keeping <br />monitoring records at the site. The Operator will also perform inventory reconciliation according to <br />the procedure outlined in the Inventory reconciliation section of this plan. <br />The electronic monitoring devices are maintained according to manufacturer's recommendations. <br />Training will be given which includes information regarding: how to self test the electronic <br />monitoring equipment, what the equipment monitors, how to tell when the alarm goes off, how to <br />perform inventory reconciliation, record keeping requirements and procedures to follow in the event <br />of alarm activation, leak, suspected leak, or other emergency. All training is in accordance with the <br />equipment manufacturer recommendations. <br />See also "Chevron Leak Response Plan" <br />Chevron Emergency Information Center (CEIC) 1-800-231-0623 <br />Chevron Maintenance Dispatch 1-800-423-3528 <br />
The URL can be used to link to this page
Your browser does not support the video tag.