Laserfiche WebLink
Don K,- Mukal" <br /> MECHANICAL ENGINEER <br /> 1841 Palma St. Pasadena, CA 911104 <br /> :323-888,.-413.6 <br /> June 1, 2010 Rev. 1024-11 <br /> Mrs.Paola Recewle-z <br /> S.Bral/o Systems, NO. <br /> 2929 Vaff Avo, <br /> Commerco, CA 90040 <br /> CCRTIlle 23,Division 3,Chapter 16,Artiold-3-See-lian?631(d) <br /> This W-Ne is foic all engilicering rewfew and a -' p.Utaiumeut <br /> pproval ofd secon dayY <br /> Systul Component whieb Is not an, integral�Firt cif primar <br /> t5 y eounindW 1fur an Undergru <br /> ond <br /> fuel tank Storage sysft-m in CaflfoTrala. T.he autharify foil thiVapaproval eoualu teow Oe <br /> Callfarniii Code of Regulatiolis (CCR) Title 23, Dlvigloia 3, Chatlier 16, Article 3, Seetiba <br /> 2631(d)l <br /> Dave examined and J:C-'Vie,��ved the following spcoificalic.11s.oil the-Bravo F-Series nlelgjass split <br /> retrofit"ROJ-ofit-S-an-a <br /> I UL CO-rdficalions Directory MI-126M 8 for Vipel F-764 aild F-774 resins <br /> 2) AOC Vij)e1.j1rodUCt SeIeCftll Otlide&Corrosion Resistance Guide <br /> 3.) Bravo dajasjieets F-SQries-SW-1 M F-Sexle�-DWM A,F-Series-BLA-1 IA, <br /> F-Si ries-D-BLR-S-11B,F-Seder-Retroflt-&I I B and F-Series-Ret-tol�-it-SI;AB-*t I A <br /> 4) Bravo Instalhilion Wnuals ii-F-8ERIES-TS-11A, I AI <br /> ii-V-SERMS-SS-09% ii-V-81?R)ES-TS-:AQJ-fNSERF,li-1i-SER1138-1 X-SS-1-1 A, <br /> V-F-$E'RTr5 8� 1A,fl-F-8�Rt: -WX49B, <br /> ii-FS-Rt,-rROF1T-S,I OC,ii-I'ME TROFIT-SD-AB-1 OA..ii-8ANDICIT--i I B <br /> 5) Brmlo Systems Th4d Party domime-tit 3RPAF-Serles wid 3RP-FS-F I X-D-BLR-S <br /> 6) Brava Systems ULAPproval document CUL-F$erieg <br /> 7) BraVO niftterfi 1l compatiliflity Tethers Simi 15LA Itenja tive,v up-13 R! fuld <br /> Fittings Aitoi�iativeFtiols R1 <br /> 8), Smith Bulletin D4015,040-10 and B2102 <br /> 9.) Amefoii PSX-'20 Adhesive.Kit-Borldsixand Product Data FP6,9'8B <br /> 10) Bravo ADTIESIVE-EPDXY-KITand ADIIESIV.E-RtTROFrT-E-poxi,:K.ii' <br /> This system provides a bonclod retrofit solutlowto teplace from ibe ifiside of-a shigle wall fiberglass <br /> CoWalmftent stunp or from boils sides oda dotible wait fiberglass eoiiiaimiient suillp, a sjjslj�e.t or <br /> failing flewbJe penetration fitting.This product imhataftis iheii1teglity of a single walled contaijiment <br /> spnip or both the priiiiary and secondary Wall, of a double wall cotrtainiijent stimp iftgludiDg the <br /> integrity of it% existing interstice by bondiiig,tlie,qtjmp wall to the fibeeglhss pipo Qr <br /> conduit atcach enfry point <br /> 3RP-F8-RETROFIT-S Conthwed on Page 4. PAGE 9 of 2 <br />