Laserfiche WebLink
RECEIVED <br /> Page 2 of 2 <br /> DEC 18 2013 <br /> 7. UNDER-DISPENSER CONTAINMENT UDC TES <br /> Test Method Developed By: ❑UDC Manufacturer ®Industry Standard ❑ <br /> ❑Other(Specify) <br /> Test Method Used: ❑Pressure ❑Vacuum ®Hydrostatic <br /> ❑ Other(Specify) <br /> Test Equipment Used: See attached testing procedures. Equipment Resolution: <br /> UDC#3/4 UDC#7/8 UDC#9/10 UDC#11/12 <br /> UDC Manufacturer: <br /> UDC Material: Fiberglass Fiberglass Fiberglass Fiberglass <br /> UDC Depth: 30" 30" 30" 30" <br /> Height from UDC Bottom to Top 10" 10" 10" 10" <br /> of Highest Piping Penetration: <br /> Height from UDC Bottom to 5" 5" 5" 5" <br /> Lowest Electrical Penetration: <br /> Condition of UDC prior to <br /> Fair Fair Fair Fair <br /> testing: <br /> Portion of UDC Tested Above highest Above highest Above highest Above highest <br /> penetration enetrationpenetration penetration <br /> Does turbine shut down when <br /> UDC sensor detects liquid(both ❑Yes ❑No®NA ❑Yes❑No®NA ❑Yes ❑No®NA ❑Yes ❑No®NA <br /> product and water)?* <br /> Turbine shutdown response time <br /> Is system programmed for fail- ❑Yes ❑No®NA ❑Yes❑No®NA ❑Yes ❑No®NA ❑Yes ❑No®NA <br /> safe shutdown?* <br /> Was fail-safe verified to be ❑Yes ❑No Z NA ❑Yes❑No®NA ❑Yes ❑No Z NA ❑Yes ❑No®NA <br /> o erational?' <br /> Wait time between applying <br /> pressure/vacuum/water and 30 minutes 30 minutes 30 minutes 30 minutes <br /> starting test <br /> Test StartTime: 9:04am 9:04am 9:37am 9:37am <br /> Initial Reading(RI): 0.2773 0.9124 4.9804 3.5871 <br /> Test End Time: 9:19am 9:19am 9:52am 9:52am <br /> Final Reading(RF): 0.2774 0.9126 4.9805 3.5865 <br /> Test Duration: 15 min 15 min 15 min 15 min <br /> Change in Reading(RF-Ri): 0.00014 0.00022 0.00007 0.00063 <br /> Pass/Fail Threshold or Criteria: g0..002 0.002 , 0.002 0.002 <br /> 'v;' 'e; ilit ,a., ,f .: ,h , .13 -z?❑.l11 .e....>x. Trt a3, „fill. .,3' '" * '„ P a Vii.. <br /> Was sensor removed for testing? ®Yes❑No❑NA ®Yes❑No❑NA ®Yes ❑No❑NA ®Yes❑No❑NA <br /> Was sensor properly replaced and ®yes❑No❑NA ®Yes❑No❑NA ®Yes❑No❑NA ®Yes QNo❑NA <br /> verified functional after testin ? <br /> Comments—(include information on repairs made prior to testing, and recommended follow-up for failed tests) <br /> Repairs made pursuant to San Joaquin County Environmental Health Permit#SR0066925 <br /> Post Repair compliance testing/inspection performed in the presence of Inspector Thuy Tran (SJC)on <br /> 6/15/2013 <br /> 6 month post repair compliance testing performed on 12/0312013 <br /> i If the entire depth of the UDC is not tested,specify how much was tested. If the answer to gny of the questions indicated with an <br /> asterisk(*)is"NO"or"NA",the entire UDC must be tested. (See SWRCB LG-160) <br />