My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2014-2017
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
T
>
TRACY
>
755
>
2300 - Underground Storage Tank Program
>
PR0508090
>
COMPLIANCE INFO_2014-2017
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/29/2023 9:06:08 AM
Creation date
6/23/2020 6:58:28 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2014-2017
RECORD_ID
PR0508090
PE
2361
FACILITY_ID
FA0007938
FACILITY_NAME
CHEVRON #208117**
STREET_NUMBER
755
Direction
S
STREET_NAME
TRACY
STREET_TYPE
BLVD
City
TRACY
Zip
95376
APN
24202029
CURRENT_STATUS
01
SITE_LOCATION
755 S TRACY BLVD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0508090_755 S TRACY_2014-2017.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
332
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
A <br /> 6. PIPING SUMP TESTING <br /> Test Method Developed By: ❑Sump Manufacturer ❑✓ Industry Standard ❑ Professional Engineer <br /> ❑Other(Spec) <br /> Test Method Used: ❑Pressure ❑Vacuum 0 Hydrostatic <br /> F]Other(Spec) <br /> Test Equipment Used: See attached testing procedures Equipment Resolution: Inches <br /> 4 <br /> 77, <br /> t <br /> Sump# 87 Sump# Sump# Sump# <br /> Sump Diameter: 48" <br /> Sump Depth: 72" <br /> Sump Material: Fiberglass <br /> Height from Tank Top to Top of 12" <br /> Highest Piping Penetration: <br /> Height from Tank Top to lowest 29„ <br /> Electrical Penetration: <br /> Condition of sump prior to testing: Fair <br /> Portion of Sump Tested' Above highest penetration <br /> Does turbine shut down when <br /> sump sensor detects liquid(both ❑Yes [-]No ❑✓NA ❑Yes []No [INA ❑Yes❑ No []NA ❑Yes ❑hIo ❑NA <br /> product and water)?* <br /> Turbine shutdown response time N/A N/A N/A N/A <br /> Is system programmed for fail-safe <br /> shutdown?* []YesYes ❑No ❑✓ NA ❑Yes ❑No ❑NA ElYes❑ No ❑NA [_1Yes ❑No ❑NA <br /> Was fail-safe verified to be ®Yes [-]No ❑✓ NA El Yes [:]No ❑NA []Yes ONo [INA Yes [:]No [:INA <br /> o erationalf <br /> Wait time between applying <br /> pressure/vacuum/water and starting 15 minutes 15 minutes 15 minutes 15 minutes <br /> test: <br /> Test Start Time: 1:39pm <br /> Initial Reading(RI): 4.49812 Inches Inches Inches Inches <br /> Test End Time: 1:54pm <br /> Final Reading(RF): 4.49792 Inches Inches Inches Inches <br /> Test Duration: 15 mins <br /> Change in Reading(RF-RI): 0.00020 <br /> Pass/Fail Threshold or Criteria: 0.002 <br /> Test Result: ❑✓ Pass ❑Fail El Pass ❑Fail ❑Pass ❑Fail ❑Pass ❑Fail <br /> Was sensor removed for testing? ❑✓Yes ❑No []NA []Yes []No [:]NA ❑Yes ❑No ❑NA ❑Yes ❑No ❑NA <br /> Was sensor properly replaced and ❑Yes ❑No ❑NA ❑Yes [:]No ❑NA ❑Yes El No [:INA 1:1Yes [-]No [:INA functional after te�tin . <br /> Comments—(include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />
The URL can be used to link to this page
Your browser does not support the video tag.