My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2004-2010
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
P
>
PACIFIC
>
4405
>
2300 - Underground Storage Tank Program
>
PR0508452
>
COMPLIANCE INFO_2004-2010
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/27/2023 3:57:30 PM
Creation date
6/23/2020 6:58:38 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2004-2010
RECORD_ID
PR0508452
PE
2361
FACILITY_ID
FA0007787
FACILITY_NAME
PACIFIC CAR WASH/MARKETPLACE INC
STREET_NUMBER
4405
STREET_NAME
PACIFIC
STREET_TYPE
AVE
City
STOCKTON
Zip
95207
APN
11024013
CURRENT_STATUS
01
SITE_LOCATION
4405 PACIFIC AVE
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0508452_4405 PACIFIC_2004-2010.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
444
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN COUNTY <br />&NVIRONMENTAL HEALTH DEPARTMENTO <br />600 East Main Street, Stockton, California 95202-3029 <br />Telephone: (209) 468-3420 Fax. (209) 468-3433 Web: MNw.smQoy.o C�ehd/unitiii.htrnl <br />L _ <br />UNDER&ROAND ST094GE T&W, f USTI PI?QG-?42LaMffXdZ&; Me= <br />Facility name: <br />Pacific Car Wash <br />Inspection date: <br />5/25/2010 <br />Facility address: <br />4405 Pacific Ave, Stockton <br />UST#1 <br />Product <br />1 <br />87 <br />91 <br />Facility contact: Title: Phone: <br />Tamara Castro Manager 478-5504 <br />lz� <br />Monitoring panel: <br />Vr Tls-350 <br />Piping system: <br />0 Pressurized ❑[I Suction ❑[] Gravity <br />Overfill prevention: <br />0 Mechanical <br />C] Audibletvisual <br />Violations: <br />0 Ml-RDetect E] M3 -Both <br />0 M2-RPrev <br />Inspection type: <br />0 Routine 0 Monitoring Certification 0 Installation El Other <br />Designated operator: ICC exp. date: <br />Karen Arnaiz 6/20/2011 <br />On site Service Technician's name: ICC exp. date: <br />Felix Ramirez 12/13/2010 <br />Manufacturer's training: <br />Tt:X-5/31/11,Vr:X-6/25/10,Vmi:X-11/11/11 <br /># <br />Code Section <br />VIOLATIONS <br />V <br />R <br />V <br />I <br />HSC=CA Health & Safety Code; CCR=CA Code of Regulations; V=Violation; RV=Repeat Violation <br />1 <br />HSC 25284 <br />No permit to operate <br />2 <br />CCR 2637 <br />Secondary containment: (a) test not performed; (a) test report not submitted within 30 days; (f) test <br />notification not provided to the Environmental Health Department (EHD) at least 48 hours poor to <br />conducting the test <br />3 <br />CCR 2711 (b) & (c) <br />Current Unified Program Consolidated Forms not on file with the EHD (Facility and tank form) <br />1 <br />4 <br />HSC 25292.2 <br />Current financial responsibility documents not on file with the EHD <br />5 <br />CCR 2632(b) <br />Monitoring Program (Monitoring & Response Plans) is not current or approved by the EHD <br />X <br />6 <br />CCR 2712(i) <br />Monitoring and/or response plan is not onsite <br />7 <br />CCR 2712(b) <br />Maintenance & monitoring records not maintained 3 years, cathodic protection records for 6 (MI) <br />years, written performance claims pertaining to release detection systems for 5 years, or records of <br />repairs, linings, and upgrades for the life of the tank. Monitoring records include: (1) date and time of <br />all monitoring or sampling; (2) monitoring equipment calibration and maintenance records; (3) results <br />of any visual observations; (4) results of sample analysis performed a lab or in the field; (5) logs of all <br />readings of gauges or other monitoring equipment, ground water elevations, or other test results; (6) <br />results of inventory readings and reconciliations <br />8 <br />CCR 2643(d) <br />Daily monitoring of suction piping (pre -January 1, 1984) not performed <br />9 <br />HSC 25292.1 <br />UST system is not operated to prevent unauthorized release, including spills and overfills, <br />10 <br />CCR 2632(c)(2) <br />Monitoring system is not present in the interstitial space of a double walled UST/piping <br />11 <br />CCR 2630(d) <br />LIST monitoring equipment is not installed or maintained to detect a leak at the earliest opportunity(mi) <br />12 <br />HSC 25291(b) <br />UST monitoring system incapable of detecting leak from primary containment into secondary (MI) <br />containment <br />X <br />13 <br />CCR 2636(f)(1) <br />Failed to maintain a continuous monitoring system for underground piping & UDCs that activates (MI) <br />an audible and visual alarm or stops flow of product at the dispenser when it detects a leak <br />14 <br />CCR 2631 (a) <br />Primary containment is not product tight <br />15 <br />HSC 25291 (a)(2) <br />Secondary containment for UST system is not tight <br />16 <br />CCR 2636(c)(1) <br />All releases in seconda!y pipi!9 do not flow to a collection sump <br />17 <br />1 CCR 2636(f)(2) <br />Line leak detector s) not installed or failed to detect a 37gallon per hour leak at 10 psi <br />18 <br />CCR 2635(b)(1) <br />Spill container not installed, failed to contain a minimum capacity of five gallons, or failed to (M2). <br />provide a means to keep the spill container empty <br />19 <br />CCR 2635(b)(2) <br />Overfill prevention system was overridden or failed to meet overfill requirements in this section (M2) <br />20 <br />CCR 2636(a) <br />Failed to have secondary containment for piping (includes conventional suction piping) (1111112) <br />21 <br />HSC 25291 (e) <br />Water in 20 containment not removed, analyzed & ropeddisposed of <br />22 <br />CCR 2650 <br />I <br />Unauthorized release that: (c) did not escape secondary containment and cleaned up within eight (FAi) <br />hours was not recorded; (e) escaped secondary containment, not cleaned up after eight hours, or a <br />I sudden loss of product was not reported to the EHD within 24 hours <br />23a <br />CCR 2715(a) <br />Failed to inform the EHP-6f**an9e of designated operator within 30 days <br />23b <br />I CCR 2715(b) <br />Designated operator did t4s* a current ICC UST System Operator certification <br />EHD Inspector: Garrett Backus <br />I <br />I Feceiv <br />fr <br />Title: <br />EHD 2s�2'-o02REV 04108/10 Page 1 LIST OFFICIAL INSPEC I ION KEPUK I <br />
The URL can be used to link to this page
Your browser does not support the video tag.