My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2011-2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
P
>
PACIFIC
>
4405
>
2300 - Underground Storage Tank Program
>
PR0508452
>
COMPLIANCE INFO_2011-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/27/2023 4:04:02 PM
Creation date
6/23/2020 6:58:50 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2011-2018
RECORD_ID
PR0508452
PE
2361
FACILITY_ID
FA0007787
FACILITY_NAME
PACIFIC CAR WASH/MARKETPLACE INC
STREET_NUMBER
4405
STREET_NAME
PACIFIC
STREET_TYPE
AVE
City
STOCKTON
Zip
95207
APN
11024013
CURRENT_STATUS
01
SITE_LOCATION
4405 PACIFIC AVE
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0508452_4405 PACIFIC_2011-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
267
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
1% <br />n <br />Appendix Vl J;1 0 2015 <br />MONITORING SYSTEM CERTIFICATION <br />For Use By All Jurisdictions Within the State of California s V 5 4, <br />Authority Cited: Chapter 6.7, Health and Safety Code; Chapter 16, Division 3, Title 23, California CodeeuXitGt <br />This form must be used to document testing and servicing of monitoring equipment. A separate certification or report must be prepared for <br />each monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank system <br />owner/operator. The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br />A. General Information <br />Facility Name: <br />Site Address: <br />Facility Contact Person: <br />PACIFIC CAR WASH Bldg. No.: <br />4405 PACIFIC BLVD. <br />TAMMI <br />City: STOCKTON <br />Contact Phone No.: <br />Zip: 95207 <br />Make/Model of Monitoring System: VEEDER ROOT TLS -350 Date of Testing/Servicing: 5/14/2015 <br />B. Inventory of Equipment Tested/Certified <br />Check the aoorooriate boxes to indicate sDecific eauioment insoected/serviced: <br />Tank ID: 87 <br />Tank Size: <br />Tank ID: 91 <br />Tank Size: <br />® In -Tank Gauging Probe. <br />Model: MAG 1 <br />® In -Tank Gauging Probe. <br />Model: MAG 1 <br />® Annular Space or Vault Sensor. <br />Model: 420 <br />® Annular Space or Vault Sensor. <br />Model: SAME VESSEL <br />® Piping Sump / Trench Sensor(s). <br />Model: 208 <br />® Piping Sump / Trench Sensor(s). <br />Model: 208 <br />❑ Fill Sump Sensor(s). <br />Model: <br />❑ Fill Sump Sensor(s). <br />Model: <br />® Mechanical Line Leak Detector. <br />Model: 99 LD 2000 <br />® Mechanical Line Leak Detector. <br />Model: 99 LD 2000 <br />❑ Electronic Line Leak Detector. <br />Model: <br />❑ Electronic Line Leak Detector. <br />Model: <br />❑ Tank Overfill / High -Level Sensor. <br />Model: <br />❑ Tank Overfill / High -Level Sensor. <br />Model: <br />❑ Other (specify equipment type and model in Section E on Page 2). <br />❑ Other (specify equipment type and model in Section E on Page 2). <br />Tank ID: <br />Tank Size: <br />Tank ID: Transition Sump <br />Tank Size: <br />❑ In -Tank Gauging Probe. <br />Model: <br />❑ In -Tank Gauging Probe. <br />Model: <br />❑ Annular Space or Vault Sensor. <br />Model: <br />❑ Annular Space or Vault Sensor. <br />Model: <br />❑ Piping Sump / Trench Sensor(s). <br />Model: <br />® Piping Sump / Trench Sensor(s). <br />Model: 208 <br />❑ Fill Sump Sensor(s). <br />Model: <br />❑ Fill Sump Sensor(s). <br />Model: <br />❑ Mechanical Line Leak Detector. <br />Model: <br />❑ Mechanical Line Leak Detector. <br />Model: <br />❑ Electronic Line Leak Detector. <br />Model: <br />❑ Electronic Line Leak Detector. <br />Model: <br />❑ Tank Overfill / High -Level Sensor. <br />Model: <br />❑ Tank Overfill / High -Level Sensor. <br />Model: <br />❑ Other (specify equipment type and model in Section E on Page 2). <br />❑ Other (specify equipment type and <br />model in Section E on Page 2). <br />Dispenser ID: 1/2 <br />Dispenser ID: 3/4 <br />® Dispenser Containment Sensor(s). <br />Model: 323 <br />® Dispenser Containment Sensor(s). <br />Model: 323 <br />® Shear Valve(s). <br />® Shear Valve(s). <br />❑ Dispenser Containment Float(s) and <br />Chain(s). <br />❑ Dispenser Containment Float(s) and Chain(s). <br />Dispenser ID: 5/6 <br />Dispenser ID: 7/8 <br />® Dispenser Containment Sensor(s). <br />Model: 323 <br />® Dispenser Containment Sensor(s). <br />Model: 323 <br />® Shear Valve(s). <br />® Shear Valve(s). <br />❑ Dispenser Containment Float(s) and Chain(s). <br />❑ Dispenser Containment Float(s) and Chain(s). <br />Dispenser ID: 9/10 <br />Dispenser ID: 11/12 <br />® Dispenser Containment <br />® Dispenser Containment Sensor(s). <br />Model: 208 <br />Sensor(s). <br />Model: 208 <br />® Shear Valve(s). <br />® Shear Valve(s). <br />❑ Dispenser Containment Float(s) and Chain(s). <br />❑ Dispenser Containment Float(s) and Chain(s). <br />"if the facility contains more tanks or dispensers, copy this form. Include information for every tank and dispenser at the facility. <br />C. Certification - I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' <br />guidelines. Attached to this Certification Is information (e.g. manufacturers' checklists) necessary to verify that this information is correct <br />and a Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating such reports, I have also attached a <br />copy of the report; (check all that apply): I@ System set-up ® Alarm history report <br />Technician Name (print): ZANE NIMMO <br />Certification A28446 <br />No.: <br />Testing Company AFFORDA-TEST <br />Name: <br />Testing Company Address: 4162 nSTREET GALT, CA 95632 <br />Monitoring System Certification <br />Signature: <br />License No: 04-1676 <br />Phone No. (209) 744-0113 <br />Date of Testing/Servicing: 5/14/15 <br />Page 1 of 4 <br />2/21/07 <br />
The URL can be used to link to this page
Your browser does not support the video tag.