Laserfiche WebLink
T <br />Appendix VI <br />MONITORING SYSTEM CERTIFICATION <br />For Use By All Jurisdictions Within the State of California RECEIVED <br />Authority Cited: Chapter 6.7, Health and Safety Code; Chapter 16, Division 3, Title 23, California CodeofRegulations <br />This form must be used to document testing and servicing of monitoring equipment. A separate certification or report must be prepared fo� 11 ��nIv 2 1 2013 <br />each monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank system <br />owner/operator. The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days <br />A. General Information HEALTH ISE ART E T <br />Facility Name: PACIFIC CAR WASH Bldg. No.: <br />Site Address: <br />Facility Contact <br />Parcnrc <br />4405 PACIFIC BLVD. <br />TAMMI <br />Make/Model of Monitoring System: VEEDER ROOT TLS -350 <br />City: STOCKTON <br />Contact Phone No.: <br />B. Inventory of Equipment Tested/Certified <br />Check the aoorooriate boxes to indicate specific eauioment inspected/serviced: <br />zip: 95207 <br />Date of Testing/Servicing: 5/23/2013 <br />Tank ID: 87 <br />Tank Size: <br />Tank ID: 91 Tank Size: <br />® In -Tank Gauging Probe. <br />Model: MAG 1 <br />® in -Tank Gauging Probe. <br />Model: MAG I <br />® Annular Space or Vault Sensor. <br />Model: 420 <br />® Annular Space or Vault Sensor. <br />Model: SAME VESSEL <br />® Piping Sump/ Trench Sensor(s). <br />Model: 208 <br />® Piping Sump/ Trench Sensor(s). <br />Model: 208 <br />❑ Fill Sump Sensor(s). <br />Model: <br />❑ Fill Sump Sensor(s). <br />Model: <br />® Mechanical Line Leak Detector. <br />Model: 99 LD 2000 <br />® Mechanical Line Leak Detector. <br />Model: 99 LD 2000 <br />❑ Electronic Line Leak Detector. <br />Model: <br />❑ Electronic Line Leak Detector. <br />Model: <br />❑ Tank Overfill / High -Level Sensor. <br />Model: <br />❑ Tank Overfill / High -Level Sensor. <br />Model: <br />❑ Other (specify equipment type and model in Section E on Page 2). <br />❑ Other (specify equipment type and model in Section E on Page 2). <br />Tank ID: <br />Tank Size: <br />Tank ID: TRANSITION <br />Tank Size: SUMP <br />❑ In -Tank Gauging Probe. <br />Model: <br />❑ In -Tank Gauging Probe. <br />Model: <br />. ❑ Annular Space or Vault Sensor. <br />Model: <br />❑ Annular Space or Vault Sensor. <br />Model: <br />❑ Piping Sump / Trench Sensor(s). <br />Model: <br />® Piping Sump / Trench Sensor(s). <br />Model: 323 <br />❑ Fill Sump Sensor(s). <br />Model: <br />❑ Fill Sump Sensor(s). <br />Model: <br />❑ Mechanical Line Leak Detector. <br />Model: <br />❑ Mechanical Line Leak Detector. <br />Model: <br />❑ Electronic Line Leak Detector. <br />Model: <br />❑ Electronic Line Leak Detector. <br />Model: <br />❑ Tank Overfill / High -Level Sensor. <br />Model: <br />❑ Tank Overfill / High -Level Sensor. <br />Model: <br />❑ Other (specify equipment type and model in Section E on Page 2). <br />❑ Other (specify equipment type and model in Section E on Page 2). <br />Dispenser ID: 1/2 <br />Dispenser ID: 3/4 <br />® Dispenser Containment Sensor(s). <br />Model: 323 <br />® Dispenser Containment Sensor(s). <br />Model: 323 <br />® Shear Valve(s). <br />® Shear Valve(s). <br />❑ Dispenser Containment Float(s) and <br />Chain(s). <br />❑ Dispenser Containment Float(s) and <br />Chain(s). <br />Dispenser ID: 5/6 <br />Dispenser ID: 7/8 <br />® Dispenser Containment Sensor(s). <br />Model: 323 <br />® Dispenser Containment Sensor(s). <br />Model: 323 <br />® Shear Valve(s). <br />® Shear Valve(s). <br />❑ Dispenser Containment Float(s) and Chain(s). <br />❑ Dispenser Containment Float(s) and Chain(s). <br />Dispenser ID: 9/10 <br />Dispenser ID: 11/12 <br />® Dispenser Containment <br />® Dispenser Containment Sensor(s). <br />Model: 208 <br />Sensor(s). <br />Model: 208 <br />® Shear Valve(s). <br />® Shear Valve(s). <br />❑ Dispenser Containment Float(s) and Chain(s). <br />❑ Dispenser Containment Float(s) and Chain(s). <br />*If the facility contains more tanks or dispensers, copy this form. Include information for every tank and dispenser at the facility. <br />C. Certification - I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' <br />guidelines. Attached to this Certification is information (e.g. manufacturers' checklists) necessary to verify that this information is correct <br />and a Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating such reports, I have also attached a <br />copy of the report; (check all that apply): ® System set-up ® Alarm history report <br />Technician Name (print): ZANE NIMMO Signature: OAVEE— <br />Certification No.: A28446 License No: 04-1676 <br />Testing Company Name: AFFORDA-TEST Phone No. (209) 744-0113 <br />Testing Company Address: 4162 nSTREET GALT, CA 95632 Date of Testing/Servicing: 5/23/13 <br />Monitoring System Certification <br />Page 1 of 4 <br />C a 11 1 <br />.,;,, <br />ld <br />._ 1i <br />2/21/07 <br />