Laserfiche WebLink
i+ <br />SAN JOAQUIN COUNTY <br />ENVIRONMENTAL HEALTH DEPARTMENT <br />600 East Main Street, Stockton, California 95202-3029 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sigov.org/ehd/unitiii.htmi <br />UNDERGROUND STORAGE TANK (UST) PROGRAM INSPECTION REPORT CONTINUED <br />Facilely Pacific Car Wash &Market lac Facility 4405 Pacific Ave, Stockton Inspection May 1, 2012 <br />Name: p Address: Date: y <br />VIOLATIONS <br /># <br />C1 <br />C2 <br />M <br />Code Section <br />HSC = CA Health and Safety Code; CFR = Code of Federal Regulations <br />C1 = Class 1 violation; C2 = Class 2 violation; M = Minor violation <br />Non -Pressurized Piping (continued) <br />702 <br />CCR 2643(e) <br />Biennial tightness test of gravity piping not performed (pre -January 1, 1984) (MI) <br />703 <br />CCR 2643(d) <br />Triennial line test for conventional suction piping not performed (pre -January 1, 1984) (M1) <br />Other Violations <br />999 Other: See attached "Continuation — Official Inspection Report" for violation(s) not listed above. <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS 11, or MINOR -Notice to Comply) <br />Routine and Monitoring System Certification UST inspection <br />205. The July 2011 designated operator monthly inspection report was not found on site. Designated <br />operator monthly inspection reports for the previous twelve months shall be retained on site. Locate and <br />ensure that copies of the previous twelve months of designated operator monthly inspection reports are <br />maintained on site. Submit a copy of the 7/2011 report to the Environmental Health Department (EHD) <br />by June 1, 2012. <br />311. The 91 octane line leak detector failed to detect a leak when tested. All line leak detectors shall be <br />capable of detecting a 3 -gallon per hour leak at 10 psi. Immediately have a properly licensed, trained, <br />and certified contractor repair or replace the failed leak detector (LG 113-x listed, if applicable) and <br />obtain a permit within one business day from the EHD. If the failed leak detector can't be replaced <br />immediately, there is a possibility that the 91 octane UST system may be red tagged to prevent fuel <br />inputs. <br />Note <br />1. Complete the following by June 1, 2012 and send to the San Joaquin County Environmental Health <br />Department: <br />a. The Return to Compliance Certification form. <br />b. A statement explaining how each violation was corrected. <br />c. Supporting documentation. <br />ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE. <br />THIS FACILITY IS SUBJECT TO REI TION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br />