COMPLIANCE INFO_2011-2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
P
>
PACIFIC
>
4405
>
2300 - Underground Storage Tank Program
>
PR0508452
>
COMPLIANCE INFO_2011-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/27/2023 4:04:02 PM
Creation date
6/23/2020 6:58:50 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2011-2018
RECORD_ID
PR0508452
PE
2361
FACILITY_ID
FA0007787
FACILITY_NAME
PACIFIC CAR WASH/MARKETPLACE INC
STREET_NUMBER
4405
STREET_NAME
PACIFIC
STREET_TYPE
AVE
City
STOCKTON
Zip
95207
APN
11024013
CURRENT_STATUS
01
SITE_LOCATION
4405 PACIFIC AVE
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0508452_4405 PACIFIC_2011-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
267
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
CENED <br /> Appendix V1 <br /> J 6-1 <br /> MONITORING SYSTEM CERTIFICATION <br /> For Use By All Jurisdictions Within the State of California <br /> Authority Cited:Chapter 6.7,Health and Safety Code;Chapter 16, Division 3,Title 23,California CodWA66ihWhimL. <br /> This form must be used to document testing and servicing of monitoring equipment.A separate certification or report m SPi;e-p,rep-gr6d,,fliif, <br /> each monitoring system control panel by the technician who performs the work.A copy of this form must be provided to the tank system <br /> owner/operator.The owner/operator must submit a copy of this form to the local agency regulating LIST systems within 30 days of test date. <br /> A. General Information <br /> Facility Name: PACIFIC CAR WASH Bldg.No.: <br /> Site Address: 4405 PACIFIC BLVD city: STOCKTON zip: 95207 <br /> Facility Contact Person: TAMMI Contact Phone No.: ( <br /> Make/Model of Monitoring System: VEEDER ROOT TLS-350 Date of Testing/Servicing: 5/15/2018 <br /> B. Inventory of Equipment Tested/Certified <br /> Check thea ro riate boxes to indicates ecific aqulpment inspected/serviced: <br /> Tank ID: 87 OCT Tank Size: 12 K Tank ID: 91 OCT Tank Size: 8 K <br /> N In-Tank Gauging Probe. Model: M A G 1 0 In-Tank Gauging Probe. Model: M A G I <br /> N Annular Space or Vault Sensor. Model: 4 2 0 - NEW Z Annular Space or Vault Sensor. Model: SHARED W/ 870ct <br /> 0 Piping Sump I Trench Sensolsl, Model: 2 1 1 0 Piping Sump I Trench Sens,,,s,, Model: 2 0 8 <br /> El Fill Sump Sensor(s). Model: [I Fill Sump Sensor(s). Model: — <br /> 0 Mechanical Line Leak Detector. Model: 99 LD 2000 0 Mechanical Line Leak Detector. Model: 99 LD 2000 <br /> 0 Electronic Line Leak Detector. Model: [] Electronic Line Leak Detector. Model: <br /> 0 Tank Overfill/High-Level Sensor. Model: E] Tank Overfill/High-Level Sensor. Model: <br /> El Other(specify equipment type and model in Section E on Page 2). El Other(specify equipment type and model in Section E on Page 2). <br /> Tank ID: Tank Size: Tank ID: Transition Sump Tank Size: <br /> El In-Tank Gauging Probe. Model: El In-Tank Gauging Probe, Model: <br /> Ej Annular Space or Vault Sensor. Model: E] Annular Space or Vault Sensor. Model: <br /> El Piping Sump I Trench Sensor(s). Model: 0 Piping Sump/Trench Sensor(s). Model: 2 0 8 <br /> El Fill Sump Sensor(s). Model: El Fill Sump Sensor(s). Model: <br /> El Mechanical Line Leak Detector. Model: El Mechanical Line Leak Detector. Model: <br /> El Electronic Line Leak Detector. Model: El Electronic Line Leak Detector. Model: <br /> [] Tank Overfill/High-Level Sensor. Model: El Tank Overfill/High-Level Sensor. Model: <br /> El Other(specify equipment type and model in Section E on Page 2). F-1 Other(specify equipment type and model in Section E on Page 2). <br /> Dispenser ID: I / 2 Dispenser ID: _3 / 4 <br /> • Dispenser Containment Sensor(s). Model: 3 2 3 Z Dispenser Containment Sensor(s). Model: 3 2 3 <br /> • ShearValve(s). 0 ShearValve(s). <br /> [I Dispenser Containment Float(s)and Chain(s). E] Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID:_5 / 6 Dispenser ID: 7 / 8 <br /> 0 Dispenser Containment Sensor(s). Model: 3 2 3 Dispenser Containment Sensor(s). Model: 3 2 3 <br /> ED ShearValve(s). ShearValve(s). <br /> E] Dispenser Containment Float(s)and Chain(s). El Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: 9 / 10 Dispenser ID: 11 / 12 <br /> 0 Dispenser Containment Sensor(s). Model: 2 0 8 N Dispenser Containment Sensor(s). Model: 2 0 8 <br /> 0 ShearValve(s). ShearValve(s). <br /> El Dispenser Containment Float(s)and Chain(s). ❑ Dispenser Containment Float(s)and Chain(s). <br /> *If the facility contains more tanks or dispensers,copy this form. Include information for every tank and dispenser at the facility. <br /> C.Certification-I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' <br /> guidelines.Attached to this Certification is information(e.g.manufacturers'checklists)necessary to verify that this information is correct <br /> and a Plot Plan showing the layout of monitoring equipment.For any equipment capable of generating such reports,I have also attached a <br /> copy of the report;(check all that apply): System set-up N Alarm history report <br /> Technician Name(print): ZANE NIMMO Signature: <br /> Certification No.: A28446 License No: 04-1676 <br /> Testing Company Name: AFFORDA-TEST Phone No. (209)744-0112 <br /> Testing Company Address: 416 21d STREET GALT,CA 95632 Date of Testing/Servicing: 5/15/2018 <br /> Monitoring System Certification Page 1 of 4 2/21/07 <br />
The URL can be used to link to this page
Your browser does not support the video tag.