My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2009-2010
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
T
>
THORNTON
>
15237
>
2300 - Underground Storage Tank Program
>
PR0517272
>
COMPLIANCE INFO_2009-2010
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/29/2023 3:26:32 PM
Creation date
6/23/2020 6:59:19 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2009-2010
RECORD_ID
PR0517272
PE
2361
FACILITY_ID
FA0012979
FACILITY_NAME
FLYING J TRAVEL PLAZA #617
STREET_NUMBER
15237
Direction
N
STREET_NAME
THORNTON
STREET_TYPE
Rd
City
Lodi
Zip
95242
APN
02519014
CURRENT_STATUS
01
SITE_LOCATION
15237 N Thornton Rd
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0517272_15237 N THORNTON_2009-2010.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
343
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FIED PROGRAM CONSOLIDATED F V, C U), <br /> UNDERGROUND STORAGE TANK <br /> MONITORING PLAN - (Page 1 of 2) <br /> TYPE OF ACTION El 1.NEW PLAN ® 2.CHANGE OF INFORMATION 490-1. <br /> PLAN TYPE ® 1.MONITORING IS IDENTICAL FOR ALL USTs AT THIS FACILITY. [ 490-2. <br /> (Check one item only) ❑ 2.THIS PLAN COVERS ONLY THE FOLLOWING UST SYSTEM(S): PERMMS"t V®®IC <br /> ES <br /> I. FACILITY INFORMATION <br /> FACILITY ID#(Agency Use Only) H 1 1• <br /> BUSINESS NAME(Same as Facility Name or DBA) FLYING J TRAVEL PLAZA 3. <br /> BUSINESS SITE ADDRESS 15237 THORNTON ROAD 7' <br /> LODI 104. <br /> H. EQUIPMENT TESTING AND PREVENTIVE MAINTENANCE <br /> Testing,preventive maintenance,and calibration of monitoring equipment(e.g.,sensors,probes,line leak detectors,etc.)must be performed at the frequency specified <br /> b the equipment manufacturers'instructions,or annually,whichever is more frequent.Such work must be performed by qualified personnel.[23 CCR§2632,2634,2638,26411 <br /> y.............e9......P........................................ .. . . . . .. .......................................... ...... ..............................._.................__.................................._............................ ....... ...... <br /> ................................... 490-3a. <br /> MONITORING EQUIPMENT IS SERVICED ® 1.ANNUALLY ❑ 99.OTHER(Specify): 490-3b. <br /> III. 'MONITORING LOCATIONS <br /> ❑ 1.NEW SITE PLOT PLAN/MAP SUBMITTED WITH THIS PLAN ® 2.SITE PLOT PLAN/MAP PREVIOUSLY SUBMITTED [23 CCR§2632,2634] 490-4. <br /> IV. T MONITORING IS PERFORMED USING T FOLLOWING METHOD(S) �Check alt <br /> ® 1.CONTINUOUS ELECTRONIC TANK MONITORING OF ANNULAR(INTERSTITIAL)SPACE(S)OR SECONDARY CONTAINMENT VAULT(S) 490.5. <br /> WITH AUDIBLE AND VISUAL ALARMS.[23 CCR§2632,26341 <br /> SECONDARY CONTAINMENT IS: ® a.DRY ❑ b.LIQUID FILLED ❑ c.PRESSURIZED ❑ d.UNDER VACUUM 490-6. <br /> PANEL MANUFACTURER: VEEDER-ROOT/OMNTEC 490-7. MODEL#: TLS-350/800011 490-8. <br /> LEAK SENSOR MANUFACTURER: VEEDER-ROOT 490-9. MODEL#(S): 303 490-10. <br /> (.................)....... ......_........................_......._........... <br /> ❑ 2.AUTOMATIC TANK GAUGING ATG SYSTEM USED TO MONITOR SINGLE WALL TANK(Sl.[23 CCR§26431 ago-11. <br /> PANEL MANUFACTURER: 490-12. MODEL#: 490-13. <br /> IN-TANK PROBE MANUFACTURER: 490-14. MODEL#(S): 490-15. <br /> LEAK TEST FREQUENCY: ❑ a.CONTINUOUS ❑ b.DAILY/NIGHTLY ❑ c.WEEKLY 490-16. <br /> ❑ d.MONTHLY ❑ e.OTHER(Specify): 490-17. <br /> PROGRAMMED TESTS: ❑ a.0.1 h. ❑ b.0.2 h. ❑ c.OTHER(Specify) 49418. <br /> _.__--.................._.....................................................................................-......... g.p.h. g•P• ( p fY) _490 19._.._. <br /> ❑ 3.MONTHLY STATISTICAL INVENTORY RECONCILIATION[23 CCR§2646.11 49420. <br /> ...-............................._..........................................._..............................................................................................................................................................................--.---.........---.._._..__..__.__.............................................................................................................................................................................1--..........................---._._.4._....2�_._. <br /> ❑ 4.WEEKLY MANUAL TANK GAUGING(MTG)[23 CCR§26451 TESTING PERIOD: ❑ a.36 HOURS ❑ b.60 HOURS 490922 <br /> .................................-- --.....--...._................................................................................................................................................................................................._.........._..................................................................................................................................................................-..................................._...... <br /> ❑ 5.TANK INTEGRITY TESTING PER[23 CCR§2643.11 490-23. <br /> TEST FREQUENCY: ❑ a.ANNUALLY ❑ b.BIENNIALLY ❑ c.OTHER(Specify): 49421. <br /> _... . . . . . ........_Q.................................................................... _.. �..._p........_z..'.�...... a9azs.__....... <br /> ........... ..................................... ................................................................................................................._............................................................__...................._.............. <br /> ® <br /> 99.OTHER(specify): VISUAL DONE DAILY 49027. <br /> V. PIPE MONITORING IS PERFORMED USING THE FOLLOWING METHOD(S) (Ch all <br /> ® 1.CONTINUOUS MONITORING OF PIPEIPIPING SUMP(S)AND OTHER SECONDARY CONTAINMENT WITH AUDIBLE&VISUAL ALARMS. 190-28. <br /> E23 CCR <br /> SECONDARY CONTAINMENT IS: ® a.DRY [-Ib.LIQUID FILLED El c.PRESSURIZED E:1 d.UNDER VACUUM 490-29. <br /> R <br /> PANEL MANUFACTURER:VEEDER-ROOT/OMNTEC 49430. MODEL#: TLS-350/800011 490.31. <br /> LEAK SENSOR MANUFACTURER: VEEDER-ROOT 490-32. MODEL#(s): 322 490-33. <br /> PIPING LEAK ALARM TRIGGERS AUTOMATIC PUMP(i.e.,TURBINE)SHUTDOWN. ® a.YES ❑ b.NO 190-34. <br /> FAILURE/DISCONNECTION OF THE MONITORING SYSTEM TRIGGERS AUTOMATIC PUMP SHUTDOWN. ® a.YES ❑ b.NO 490-35. <br /> .................................................................._...................._................................................................................................._......._................................................................................_...................................................................................._..._..__._..._.._...._.__._............_..........._._....._....._..................................................................................................................... <br /> ® 2.MECHANICAL LINE LEAK DETECTOR(MLLD)THAT ROUTINELY PERFORMS 3.0 g.p.h. LEAK TESTS AND RESTRICTS OR SHUTS OFF 490-36. <br /> PRODUCT FLOW WHEN A LEAK IS DETECTED.[23 CCR§26361 <br /> MLLD MANUFACTURER(S):FE PETRO 490-37. MODEL#(S): MLD 490-38. <br /> ❑ 3.ELECTRONIC LINE LEAK DETECTOR(ELLD)THAT ROUTINELY PERFORMS 3.0 g.p.h.LEAK TESTS.[23 CCR§26361 490-39. <br /> ELLD MANUFACTURER(S): <br /> 490-40. MODEL#(S): 490-41. <br /> PROGRAMMED IN LINE LEAK TEST: ❑ a.MINIMUM MONTHLY 0.2 g.p.h. ❑ b.MINIMUM ANNUAL 0.1 g.p.h. 490-42. <br /> ELLD DETECTION OF A PIPING LEAK TRIGGERS AUTOMATIC PUMP SHUTDOWN. ❑ a.YES ❑ b.NO 490.43. <br /> ELLD FAILURE/DISCONNECTION TRIGGERS AUTOMATIC PUMP SHUTDOWN. ❑ a.YES ❑ b.NO 490-44. <br /> .............................................................................................................................................................................................................._..................._._._..._.__.._.._.._.._...... <br /> ® 4.PIPE INTEGRITY TESTING. ago-as. <br /> 490-46. <br /> TEST FREQUENCY: ❑ a.ANNUALLY ❑ b.EVERY 3 YEARS ® c.OTHER(Specify) N/A D/T os.shutdown 490-17,..__... <br /> ..........._. ..................................................................................................................................................................................................................... _._................. <br /> ❑ 5.VISUAL PIPE MONITORING. 49445. <br /> FREQUENCY: ❑ a.DAILY ❑ b.WEEKLY ❑ c.MIN.MONTHLY&EACH TIME SYSTEM OPERATED* 490-49• <br /> ..............................._ Allowed_for,monitorin,of unburied emer�eocy..generator,fuel..piP�n.ooly.per HSC§25281..5(63)......___._.......... <br /> ❑ 6.SUCTION PIPING MEETS EXEMPTION CRITERIA.[23 CCR§2636(a)(3)1 490-so. <br /> .............................................................................................................................................................................................................................................................................................................................._......_........................................................................................................................................................................................._.._.............I............................_........ <br /> ❑ 7.NO REGULATED PIPING PER HEALTH AND SAFETY CODE,DIVISION 20,CHAPTER 6.7 IS CONNECTED TO THE TANK SYSTEM. 490-51. <br /> ......................................................................................................................................................................................................................................................................................................................_............................................................................................................................................................................................................................................... <br /> .._..._..........._. <br /> ❑ 99.OTHER(Specify) 49452. <br /> 490-53. <br /> UPCF UST-D(12/2007)-1/4 www.unidocs.org <br />
The URL can be used to link to this page
Your browser does not support the video tag.