Laserfiche WebLink
UNIFIED PROGRAM CONSOLIDATED FORM <br /> UNDERGROUND STORAGE TANK <br /> MONITORING PLAN-LpaLe 1 of 2) <br /> TYPE OF ACTION ❑ 1.NEW PLAN ® 2.CHANGE OF INFORMATION 49°-1 <br /> PLAN TYPE ® 1.MONITORING IS IDENTICAL FOR ALL USTs AT THIS FACILITY. 490.2 <br /> (Check one item only) ❑ 2.THIS PLAN COVERS ONLY THE FOLLOWING UST SYSTEM( )i <br /> I. FACILITY INFORMATION <br /> FACILITY ID#(Agency Use Only) 3. <br /> BUSINESS NAME(Same as FACILITY NAME) Flying J Travel Plaza-#617 <br /> BUSINESS SITE ADDRESS 15237 N. Thornton Rd 103 CITY Lodi '"` <br /> M EQUIPMENT TESTING AND PREVENTIVE MAINTENANCE <br /> Testing,preventive maintenance,and calibration of monitoring equipment(e.g.,sensors,probes,line leak detectors,etc.)must be performed at the frequency <br /> specified by the equipment manufacturers'instructions,or annually,whichever is more frequent,and that such work must be performed by qualified personnel. <br /> 23 CCR§2632 4,26382641) <br /> - ------------------------------------- -- ---- --- --- _----- - - -- -- <br /> MONITORING EQUIPMENT IS SERVICED ® 1.ANNUALLY ❑ 99.OTHER(Specify): 490.3b <br /> Q ( P �)• 490.36 <br /> M.MONITORING LOCATIONS <br /> ®1.NEW SITE PLOT PLAN~SUBMITTED WITH THIS PLAN. ❑2.SITE PLOT PLAN/MAP PREVIOUSLY SUBMITTED. (23 CCR§2632, <br /> 2634)490-4 <br /> W.TANK MONITORING IS PERFORMED USING THE FOLLOWING METHOD(S): <br /> 1.CONTINUOUS ELECTRONIC TANK MONITORING OF ANNULAR(INTERSTITIAL)SPACE(S)OR SECONDARY CONTAINMENT 490.5 <br /> VAULT(S)WITH AUDIBLE AND VISUAL ALARMS. (23 CCR§2632,2634) <br /> SECONDARY CONTAINMENT IS: ❑ a.DRY ® b.LIQUID FILLED ❑ c.PRESSURIZED ❑d.UNDER VACUUM 490-6 <br /> PANEL MANUFACTURER: Veeder Root -- 490 7. I MODEL_#:_TLS-350 490,0, <br /> LEAK SENSOR MANUFACTURER: Veeder Root 440-9. MODEL#(S): 794380-303 490.10 <br /> 2.AUTOMATIC TANK GAUGING(ATG)SYSTEM USED TO MONITOR SINGLE WALL TANK(S).(23 CCR§2643) 490-11 <br /> PANEL MANUFACTURER: 190-12• MODEL#: 490-13 <br /> IN-TANK PROBE MANUFACTURER: 490.14. MODEL#(S): 490.19 <br /> - --_ -- -- _ -- -- - -- --- - - ----- -- ------------------------- <br /> LEAK TEST FREQUENCY: ❑ a.CONTINUOUS ❑ b.DAILYMIGHTLY ❑ c.WEEKLY 490-16 <br /> ❑ d.MONTHLY ❑ e.OTHER(Specify): - 490-17 <br /> ------- - - - - ---- -- -- ---_-- - --- __-_ - - - _ - - -.. <br /> PROGRAMMED TESTS: ❑ a.0.1 h. ❑ b.0.2 h. ❑ c.OTHER(Specify):fpy� <br /> 490-19 <br /> g.p.h. g•P• P V): 490-19 <br /> ❑ 3.MONTHLY STATISTICAL INVENTORY RECONCILIATION(23 CCR§2646.1): 490.20 <br /> ❑ 4.WEEKLY MANUAL TANK GAUGING(MTG)(23 CCR§2645). TESTING PERIOD: F1 a.36 HOURS [Ib.60 HOURS <br /> 490-21 <br /> F15.TANK INTEGRITY TESTING(23 CCR§2643.1): 490-23 <br /> TEST FREQUENCY: El a.ANNUALLY b.BIENNIALLY El c.OTHER(Specify): 490-24 <br /> 490.25 <br /> ❑ <br /> 99.OTHER (Specify):VISUAL DONE DAILY 490-26 <br /> 490-0,7 <br /> V.PIPE MONITORING IS PERFORMED USING THE FOLLOWING METHOD(S):(Check all that apply) <br /> ®1.CONTINUOUS MONITORING OF PIPE/PIPING SUMP(S)AND OTHER SECONDARY CONTAINMENT WITH AUDIBLE AND 490,29 <br /> VISUAL ALARMS. (23 CCR§2636) <br /> SECONDARY CONTAINMENT IS:®a.DRY ❑b.LIQUID FILLED ❑c.PRESSURIZED [1d.UNDER VACUUM 49°-21 <br /> 490-31 <br /> 490-30 <br /> PANEL MANUFACTURER: Veeder Root MODEL#: TLS-350 <br /> 490.32 <br /> 490.33 <br /> LEAK SENSOR MANUFACTURER: Veeder Root MODEL#(S)_794380-322 <br /> PIPING LEAK ALARM TRIGGERS AUTOMATIC PUMP(i.e.,TURBINE)SHUTDOWN. ®a.YES ❑b.NO 490.74 <br /> FAILUREMISCONNECTION OF THE MONITORING SYSTEM TRIGGERS AUTOMATIC PUMP SHUTDOWN. ®a.YES ❑b.NO 490-35 <br /> ® 2.MECHANICAL LINE LEAK DETECTOR(MLLD)THAT ROUTINELY PERFORMS 3.0 g.p.h.LEAK TESTS AND RESTRICTS OR SHUTS OFF <br /> PRODUCT FLOW WHEN A LEAK IS DETECTED CCR_§2636Z....--______--490.37 490-36 <br /> MLLD MANUFACTURER(S): FE PETRO MODEL.#(S): MLD 490-38 <br /> ❑ 3.ELECTRONIC LINE LEAK DETECTOR(ELLD)THAT ROUTINELY PERFORMS 3.0 g.p.h.LEAK TESTS (23 CCR§2636) 490.39 <br /> ELLD MANUFACTURER(S) 490-40. MODEL#(S): 49°41 <br /> ---------------_ ---_ __-_ _ -- ------- -- - --- - ---- -------- - <br /> PROGRAMMED IN LINE LEAK TEST: ❑ 1.MINIMUM MONTHLY 0.2 g.p.h. ❑ 2.MINIMUM ANNUAL 0.1 g.p.h. 49042 <br /> ELLD DETECTION OF A PIPING LEAK TRIGGERS AUTOMATIC PUMP SHUTDOWN. ❑a.YES ❑b.NO 490-43 <br /> ELLD FAILURE/DISCONNECTION TRIGGERS AUTOMATIC PUMP SHUTDOWN. E]a.YES Elb.NO 49044 <br /> ® 4.PIPE INTEGRITY TESTING 49045 <br /> TEST FREQUENCY ❑ a.ANNUALLY ❑ b.EVERY 3 YEARS ❑ c.OTHER(Specify)N/A D/Tpos.shutdOWn <br /> 49046 49047 <br /> 5.VISUAL PIPE MONITORING. 490.43 <br /> FREQUENCY ❑ a.DAILY ❑ b.WEEKLY ❑c.MIN.MONTHLY&EACH TIME SYSTEM OPERATED* 490.49 <br /> °Allowed for moritoring monitoringof unburied mergency geamtor fuel piping only per HSC§25291.5 <br /> ❑ 6.SUCTION PIPING MEETS EXEMPTION CRITERIA[23 CCR§2636(a)(3)]. 490.50 <br /> ❑ 7.NO REGULATED PIPING PER HEALTH AND SAFETY CODE,DIVISION 20,CHAPTER 6.7 IS CONNECTED TO THE TANK SYSTEM <br /> 490-51 <br /> 490-sz <br /> t ❑ 99.OTHER(Specify) 4 <br /> UPCF UST-D(12/2007) <br />