My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2011
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
T
>
THORNTON
>
15237
>
2300 - Underground Storage Tank Program
>
PR0517272
>
COMPLIANCE INFO_2011
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/30/2020 10:41:44 AM
Creation date
6/23/2020 6:59:21 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2011
RECORD_ID
PR0517272
PE
2361
FACILITY_ID
FA0012979
FACILITY_NAME
FLYING J TRAVEL PLAZA #617
STREET_NUMBER
15237
Direction
N
STREET_NAME
THORNTON
STREET_TYPE
Rd
City
Lodi
Zip
95242
APN
02519014
CURRENT_STATUS
01
SITE_LOCATION
15237 N Thornton Rd
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0517272_15237 N THORNTON_2011.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
321
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
The voltage in the device description above identifies the circuit board power, dispenser input <br />signal levels, and the coil rating for the optional relay. Control boxes with relays installed have <br />contacts rated DPST 30A, 240V, 50/60 Hz. Refer to Figure 1 for correct electrical connections <br />to the control box, <br />CHANNEL& - <br />208 TO 240V <br />CHANNEL7 - <br />Installation Guide <br />CHANNELS - <br />OR 120V OR <br />Model Information <br />(NEUTRAL) <br />240V 240V <br />TERMINAL <br />CHANNEL4 - <br />The voltage in the device description above identifies the circuit board power, dispenser input <br />signal levels, and the coil rating for the optional relay. Control boxes with relays installed have <br />contacts rated DPST 30A, 240V, 50/60 Hz. Refer to Figure 1 for correct electrical connections <br />to the control box, <br />Figure 1 <br />1 <br />f 2 <br />CHANNEL 1 <br />CHANNEL2 <br />CHANNEL3 <br />(HOT) CHANNEL4 <br />CHANNELS <br />CHANNELS <br />CHANNEL7 <br />CHANNELS <br />OUTPUT TO CIRCUIT <br />FROM CIRCUIT <br />1A <br />T61 <br />1 2 3 4 5 6 7 8 <br />DISPENSER INPUTS <br />PHASE ON L1 MUST BE SAME AS DEVICE <br />CONNECTED TO ATG TERMINAL ATG <br />OPTIONAL RELAY <br />OUTPUT COIL <br />CHANNEL& - <br />208 TO 240V <br />CHANNEL7 - <br />I PANEL <br />CHANNELS - <br />OR 120V OR <br />CHANNEL5 - <br />(NEUTRAL) <br />240V 240V <br />TERMINAL <br />CHANNEL4 - <br />TO ATG FROM ATG <br />CHANNEL3-P <br />ONLY) <br />CHANNEL2 - <br />NEUTRALOF <br />CHANNELI - <br />DISPENSER <br />SUPPLY PANEL <br />SIGNAL <br />NEUTRAL <br />WIRES <br />120V: ISOTROL 1.8R <br />TB2 <br />ISOTROL 1-8 <br />HOT <br />240V: ISOTROL 1-8R- <br />ISOTROL 1-8-i <br />Figure 1 <br />1 <br />f 2 <br />CHANNEL 1 <br />CHANNEL2 <br />CHANNEL3 <br />(HOT) CHANNEL4 <br />CHANNELS <br />CHANNELS <br />CHANNEL7 <br />CHANNELS <br />OUTPUT TO CIRCUIT <br />FROM CIRCUIT <br />1A <br />T61 <br />1 2 3 4 5 6 7 8 <br />DISPENSER INPUTS <br />PHASE ON L1 MUST BE SAME AS DEVICE <br />CONNECTED TO ATG TERMINAL ATG <br />OPTIONAL RELAY <br />OUTPUT COIL <br />FROM SUPPLY <br />208 TO 240V <br />I 20 TERMINAL <br />I PANEL <br />TO PUMP <br />OR 120V OR <br />(NOTE: L2 <br />(RELAY <br />240V 240V <br />TERMINAL <br />VERSION <br />TO ATG FROM ATG <br />CONNECTS TO <br />ONLY) <br />NEUTRALOF <br />SUPPLY PANEL <br />OR <br />FOR2-WIRE <br />MODELS <br />- CASE <br />JUMPER TO <br />CONTROL RELAY <br />ON BOARD <br />MAKE GROUND <br />DIRECTLY <br />CONNECTION IN <br />Ei <br />ACCORDANCE WITH <br />ATG TO $2 <br />LOCAL CODES <br />IN EXISTING 860-041.5, <br />880.045.5 AND 880-046.5 <br />WIRING MUST BE RATED 90°C MIN. <br />RED JACKET CONTROL BOXES <br />This device is not compatible with the Red Jacket Control Box 880-042-5. Consider replacing <br />880-042-5 in an existing location with ISCTROL 1-8-i that has the on -board relay. Compatibility <br />of this device with Control Box Models 880-041-5, 880-045-5 and 880-046-5 assumes that they <br />have been installed and wired according to their diagrams. <br />Locate an area that allows all wiring to enter through the bottom knockouts of the control box. Consider <br />the ability to view the indicator on the side of the base when choosing a location. <br />Remove the cover of enclosure and mount the base. <br />Always lock or tag out the supply power before attempting to connect to the dispenser isolation <br />control box. Use a voltmeter to verify the presence of voltages. <br />2 <br />1 <br />