Laserfiche WebLink
1. It is a condition of manufacture that each motor be subjected to the routine high <br />voltage test of clause 6.2 of AS2380.1. <br />2. It is a condition of safe use that all submerged turbine pumps, manifolds and <br />associated equipment be installed in accordance with the manufacture's <br />Installation, Operation and Service Manuals supplied <br />3. It is a condition of safe use that all installations must provide reliable electrical <br />connection between the pump motor, frame, pipe, manifold or junction box and <br />the tank structure for both electrical protection and equipotential bonding. <br />4. It is a condition of safe use that, where terminal boxes are used for termination of <br />the cables from the motor and the supply source, they shall be Australian certified <br />for use in Gas Group IIA and Zone I hazardous areas. <br />5. It is a condition of safe use that where a differential pressure switch or transducer <br />is installed, each must be capable of ensuring that the nominated temperature <br />classification is not exceeded. <br />