My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_JAN 2011-JUN 2011
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
T
>
THORNTON
>
15237
>
2300 - Underground Storage Tank Program
>
PR0517272
>
COMPLIANCE INFO_JAN 2011-JUN 2011
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/30/2020 10:41:46 AM
Creation date
6/23/2020 6:59:30 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
JAN 2011-JUN 2011
RECORD_ID
PR0517272
PE
2361
FACILITY_ID
FA0012979
FACILITY_NAME
FLYING J TRAVEL PLAZA #617
STREET_NUMBER
15237
Direction
N
STREET_NAME
THORNTON
STREET_TYPE
Rd
City
Lodi
Zip
95242
APN
02519014
CURRENT_STATUS
01
SITE_LOCATION
15237 N Thornton Rd
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0517272_15237 N THORNTON_JAN 2011-JUN 2011.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
316
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
CI <br />This form tells whether the tank tightness testing method described below complies with the performance <br />requirements of the federal underground storage tank regulation. The evaluation was conducted by the <br />equipment manufacturer or a consultant to the manufacturer according to the U.S. EPA's "Standard Test <br />Procedure for Evaluating Leak Detection Methods: Volumetric Tank Tightness Testing Methods." The full <br />evaluation report also includes a form describing the method and a form summarizing the test data. <br />Tank owners using this leak detection system should keep this form on file to provide compliance with the federal <br />regulations. Tank owners should check with State and local agencies to make sure this form satisfies their <br />requirements. <br />Method Description <br />Name TLS-250/250i/300/300i/3000/300PC/350/350PC/350R/350RPC UST Monitoring Systems <br />Version number 8463. 8473. or 8493 Digital Sensing Probe (Magnetostrictive) <br />Vendor Veeder Root <br />125 Powder Forest Drive P.O. Box 2003 <br />(street address) <br />Simsbury CT 06070-2003 (860) 651-2700 <br />(city) (state) (zip) (phone) <br />Evaluation Results <br />This ATGS which declares tank to be leaking when the measured leak rate exceeds the threshold of 0.71 <br />gallon per hour, has a probability of false alarms [PFA] of 1.0 %. <br />The corresponding probability of detection [Pp] of a 0.10 gallon per hour leak is 99.0 %. <br />Therefore, this method (X ) does ( ) lees flet meet the federal performance standards established by the U.S. <br />Environmental Protection Agency (0.10 gallon per hour at Pp of 95% and PFA of 5%). <br />The evaluation testing was conducted in a 10.000 gallon(X)steel( ) fiberglass tank that was 96 inches in <br />diameter and 324 inches long. <br />The temperature difference between product added to fill the tank and product already in the tank ranged from <br />—11.4 OF to +7.1 OF, with a standard deviation of 5.71 OF. <br />The product used in the evaluation was No. 2. Diesel . <br />Volumetric TTT - Results Form Page 1 of 2 <br />
The URL can be used to link to this page
Your browser does not support the video tag.