EHD Program Facility Records by Street Name
>
C
>
COLEY
>
1812
>
2300 - Underground Storage Tank Program
>
PR0231881
>
COMPLIANCE INFO_2012-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/15/2022 11:15:56 AM
Creation date
6/23/2020 6:59:44 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2012-2018
RECORD_ID
PR0231881
PE
2371
FACILITY_ID
FA0003946
FACILITY_NAME
AT&T California - UG010
STREET_NUMBER
1812
STREET_NAME
COLEY
STREET_TYPE
Ave
City
Escalon
Zip
95320
APN
22715414
CURRENT_STATUS
01
SITE_LOCATION
1812 Coley Ave
P_LOCATION
06
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2371_PR0231881_1812 COLEY_2012-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
288
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
pill Bucket Testing Report Form* <br />This form is intended for use by contractors performing annual testing of UST spill containment structures. The completed form and <br />printouts from tests (if applicable), should be provided to the facility owner/operatorfor submittal to the local regulatory agency. <br />FAC TLITV iNFORMATiON Fnrility ill• ii( nIn <br />Facility Name: Pacific Bell Telephone Co. dba AT&T California Date of Testing: 3/26/2014 <br />Facility Address: 1812 COLEY AVE., Escalon, CA 95320 <br />Facility Contact: Dave Dube <br />Phone: 209-4744022 <br />Date Local Agency Was Notified of Testing. 2014-03-06 <br />Name of Local Agency Inspector (if present during testing): Elena Manzo <br />TESTING CONTRACTOR INFORMATION <br />Company Name: TAIT Environmental Services, Inc. -®' ®"'4-1v I <br />Technician Conducting Test: Victor Guerrero <br />Credential' : r CSLB Contractor F ICC Service Tech. r SWRCB Tank Tester r Other (Specify) <br />License number(s): A B ASB C-10 HAZ License Number 588098 : 8017001 -UT <br />SPILL RiiCKFT TFCTiNG.iNFnRMATinN <br />9, <br />Test M ethod Used: Hydrostatic Vacuum F Other <br />Test Equipment Used: Tape Measure <br />Equipment Resolution: 1/16" <br />Identify Spill Bucket (By Tank <br />Number, Stored Product, etc.) <br />1 UG010U001 <br />Bucket Installation Type: <br />Direct Bury <br />Contained in Sump <br />On top of AST <br />Direct Bury <br />r Contained in Sump <br />On top of AST' <br />FDirect Bury <br />Contained in Sump <br />On top of AST <br />Direct Bury <br />Contained in Sump <br />r On top of AST <br />Bucket Diameter: <br />11" <br />Bucket Depth: <br />15" <br />Wait time between applying <br />vacuum/water and start of test: <br />15 min. <br />Test Start Time (Ti): <br />NA <br />Initial Reading (Rl): <br />NA <br />Test End Time (TF): <br />NA <br />Final Reading (RF): <br />NA <br />Test Duration (TF — Ti): <br />NA <br />Change in Reading (RF -Ri): <br />NA <br />Pass/Fail Threshold or <br />Criteria: <br />0 <br />Test Result: <br />Pass F Fail <br />Pass r— Fail <br />f— Pass r— Fail <br />r— Pass Fail <br />Comments —(include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />The spill bucket failed due to leakingdrain valve. All test water was taken backto Tait's shop. <br />CERTIFICATION OF TECHNICIAN RESPONSIBLE FOR CONDUCTING THIS TESTING <br />I herebycertify that all the information contained in this report is true, accurate, and in full compliance with legal requirements. <br />Technician's Signature: Date: 3/26/2014 <br />
The URL can be used to link to this page
Your browser does not support the video tag.