My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2012-2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
C
>
COLEY
>
1812
>
2300 - Underground Storage Tank Program
>
PR0231881
>
COMPLIANCE INFO_2012-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/15/2022 11:15:56 AM
Creation date
6/23/2020 6:59:44 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2012-2018
RECORD_ID
PR0231881
PE
2371
FACILITY_ID
FA0003946
FACILITY_NAME
AT&T California - UG010
STREET_NUMBER
1812
STREET_NAME
COLEY
STREET_TYPE
Ave
City
Escalon
Zip
95320
APN
22715414
CURRENT_STATUS
01
SITE_LOCATION
1812 Coley Ave
P_LOCATION
06
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2371_PR0231881_1812 COLEY_2012-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
288
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
File MH28727 Vol 1 EGVV Page 1 Issued: 2012-10-09 <br />Listing Mark Data Page (LMDP) <br />(FILE IMMEDIATELY AFTER AUTHORIZATION PAGE) <br />LISTING MARK <br />The Listing Mark consists of four elements placed in close proximity and shall <br />appear on Listed products only. Minimum size is not specified, as long as the <br />listing Mark is legible. The following is suggested. <br />XXXX = the control number assigned by UL, 8JA7 <br />The minimum height of a registered trademark symbol shall be 3/64 of an <br />inch. When the overall diameter of the UL Mark is less than 3/8 0£ an inch, <br />the trademark symbol may be omitted if it is not legible to the naked eye. <br />The product identity is: "FLAMMABLE AND COMBUSTIBLE LIQUID TANK ACCESSORY". <br />The product identity may be omitted if the Mark is directly and permanently <br />applied the product by stamping, molding, <br />ink stamping, silk screening or similar process. The product identity may <br />appear elsewhere on the product if the three elements are part of the <br />nameplate which includes the rating or the catalog or model designation. <br />Separable Listing Mark (not part of the nameplate and in the form of decals, <br />stickers or labels) will always include the four elements. <br />The manufacturer may reproduce the Mark or obtain it from a UL authorized <br />supplier <br />THIS PAGE IS TO BE REVISED BY FUS DEPARTMENT ONLY <br />File MH28727 Page T5-1 of 2 Issued: 2012-10-09 <br />TEST RECORD NO. 5 <br />SAMPLES: <br />Samples of the Models RFSF1.4 (non split) and IRF L3.5P <br />(split ) sump penetration fittings fabricated of "Fortex 92 "and the <br />split fitting bonded with FastFuse glue and Filled with Urethane <br />Sealant were submitted by the manufacturer. The sump penetration <br />fittings were installed by the manufacturer to the bottom of 5 <br />gallon polyethylene buckets. Short lengths of plugged pipe were band <br />clamped to each fitting and the fittings were filled with Urethane <br />Sealant. The SBL3.5 split repair fittings were bonded with FastFuse <br />Glue. Each bucket had provision for filling, sealing and <br />pressurizing. <br />GENERAL: <br />The test results relate only to the items tested. <br />The following tests were conducted with the results indicated. <br />SIMULATED USE RESISTANCE TO FLUIDS TEST: <br />METHOD <br />One container as described above was filled with each of the fluids <br />Listed below such that the fittings inside the sump were completely <br />covered with the fluids. The samples and fluids were maintained at a <br />temperature of 100°F throughout the exposure. Following 30 days in <br />this condition, the containers were subjected to an internal pressure <br />of 3 psig (based on a maximum sump depth of 7 ft.) while the samples <br />were examined for evidence of leakage. <br />Premium Leaded <br />Gas <br />50% <br />Methanol/50% <br />ASTM Reference <br />Fuel C <br />Regular Unleaded Gas <br />50% <br />Ethanol/50% <br />ASTM Reference <br />Fuel C <br />ASTM Reference <br />Oil 2 <br />15% <br />Methanol/85°. <br />ASTM Reference <br />Fuel C <br />ASTM Reference <br />Fuel A <br />15% <br />Ethanol/85% <br />ASTM Reference <br />Fuel C <br />ASTM Reference <br />Fuel C <br />100% <br />Ethanol <br />Toluene <br />10% <br />Ethanol/90% <br />ASTM Reference <br />Fuel C <br />100% Methanol <br />30% <br />Ethanol/70% <br />ASTM Reference <br />Fuel C <br />70oC Air Oven <br />RESULTS <br />There was no evidence of leakage. <br />
The URL can be used to link to this page
Your browser does not support the video tag.