My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2002-2006
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
E
>
EIGHTH
>
717
>
2300 - Underground Storage Tank Program
>
PR0522448
>
COMPLIANCE INFO_2002-2006
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/25/2024 4:47:24 PM
Creation date
6/23/2020 6:59:47 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2002-2006
RECORD_ID
PR0522448
PE
2371
FACILITY_ID
FA0015274
FACILITY_NAME
SHELL I-5
STREET_NUMBER
717
Direction
W
STREET_NAME
EIGHTH
STREET_TYPE
ST
City
STOCKTON
Zip
95206
APN
16314045
CURRENT_STATUS
01
SITE_LOCATION
717 W EIGHTH ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2371_PR0522448_717 W EIGHTH_2002-2006.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
404
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB,January 2002 Page of <br /> 7. ER-DISPENSER CONTAINMENT C TESTING <br /> Test Method Developed By: ❑UDC Manufacturer ,91ndustry Standard ❑Professional Engineer <br /> ❑Other(Spec) <br /> Test Method Used: ❑Pressure ❑Vacuum °Hydrostatic <br /> ❑Other(Specify) <br /> Test Equipment Used: Equipment Resolution: <br /> UDC# 1"-Z-- UDC# UDC# !G UDC# <br /> UDC Manufacturer: <br /> UDC Material: <br /> UDC De the [7, <br /> Height from UDC Bottom to Top <br /> of Highest Piping Penetration: /d /D <br /> Height from UDC Bottom to .. i41 <br /> Lowest Electrical Penetration: <br /> Condition of UDC prior to <br /> testing: <br /> Portion of UDC Tested /I-'''e /..� ' `t <br /> Does turbine shut down when <br /> UDC sensor detects liquid(both ,dCYes ❑No ❑NA 9�(es ❑No ❑NA J Yes ❑No ❑NA P(Yes ❑No ❑NA <br /> product and water ?' <br /> Turbine shutdown response time <br /> Is system programmed for fail- P(Yes ❑No ❑NA , 'Yes ❑No ❑NA es ❑No ❑NA ,ltYes No ❑NA <br /> safe shutdown? <br /> Was fail-safe verified to be <br /> operational?* , Yes ❑No ❑NA )(Yes ❑No ❑NA RYes ❑No ❑NA A?Yes ❑No ❑NA <br /> Wait time between applying <br /> pressure/vacuum/water and <br /> starting test <br /> Test Start Time: <br /> Initial Reading(RI): ,/ ®< ,e, <br /> Test End Time: A' / <br /> Final Reading <br /> Test Duration: <br /> Change in Reading(RF-RI): <br /> Pass/Fail Threshold or Criteria: t1T <br /> Test Result: XPass 0 Fail P�Pass ❑Fail ('Pass ❑Fail Pass ❑Fail <br /> Was sensor removed for testing? itrYes ❑No ❑NA ,.t Yes ❑No [INA es ❑No ❑NA es ❑No ❑NA <br /> Was sensor properly replaced anda <br /> verified functional after testin ? Yes ❑No ❑NA , Yes ❑No ❑NA �'1'es ❑No 0 NA 'Yes El No !_:N. <br /> Comments— (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br /> ' If the entire depth of the UDC is not tested,specify how much was tested. If the answer to Agy of the questions indicated with an <br /> asterisk(*) is"NO"or"NA",the entire UDC must be tested. (See SWRCB LG-160) <br /> r <br />
The URL can be used to link to this page
Your browser does not support the video tag.