COMPLIANCE INFO_2016-2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
E
>
EIGHTH
>
717
>
2300 - Underground Storage Tank Program
>
PR0522448
>
COMPLIANCE INFO_2016-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/12/2023 3:02:54 PM
Creation date
6/23/2020 6:59:48 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2016-2018
RECORD_ID
PR0522448
PE
2371
FACILITY_ID
FA0015274
FACILITY_NAME
SHELL I-5
STREET_NUMBER
717
Direction
W
STREET_NAME
EIGHTH
STREET_TYPE
ST
City
STOCKTON
Zip
95206
APN
16314045
CURRENT_STATUS
01
SITE_LOCATION
717 W EIGHTH ST
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2371_PR0522448_717 W EIGHTH_2016-2018.tif
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
198
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
0 RECEIVED <br /> MONITORING SYSTEM CERTIFICATION APR 0 9 2018 <br /> For Use By All Jurisdictions Within the State of California <br /> Authority Cited: Chapter 6.7,Health and Safety Code; Chapter 16,Division 3, Title 23, California Code of Regulations <br /> ENVIRONMENTAL <br /> This form must be used to document testing and servicing of monitoring equipment. A separate certification or report <br /> monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the to sys em owner/operator. NT <br /> The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br /> A. General Information <br /> Facility Name: Shell 1-5 Bldg.No.: <br /> Site Address: 717 W. Eighth St. City: Stockton Zip: 95206 <br /> Facility Contact Person: Owner-Joe Contact Phone No.: (209) 939-0961 <br /> Make/Model of Monitoring System: Veederoot TLS350 Date of Testing/Servicing: 3/8/2018 <br /> B. Inventory of Equipment Tested/Certified <br /> Check the appropriate boxes to indicatespecific equipment inspected/serviced: <br /> Tank ID: #1-Regular Tank ID: #2-Premium <br /> ®In-Tank Gauging Probe. Model: 847390-109 ®In-Tank Gauging Probe. Model: 847390-109 <br /> ®Annular Space or Vault Sensor. Model: 794390-303 ®Annular Space or Vault Sensor. Model: 794390-303 w Split tank <br /> ®Piping Sump/Trench Sensor(s). Model: 794380-208 ®Piping Sump/Trench Sensor(s). Model: 794380-208 <br /> ®Fill Sump Sensor(s). Model: 794380-208 ®Fill Sump Sensor(s). Model: 794380-208 <br /> ®Mechanical Line Leak Detector. Model: Veederoot FX1 V ®Mechanical Line Leak Detector. Model: VMI LD2000 <br /> ❑Electronic Line Leak Detector. Model: ❑Electronic Line Leak Detector. Model: <br /> ®Tank Overfill/High-Level Sensor. Model: ATG ®Tank Overfill/High-Level Sensor. Model: ATG <br /> ❑Other(specify equipment type and model in Section E on Page 2). ❑Other(specify equipment type and model in Section E on Page 2). <br /> Tank ID: #3-Diesel Tank ID: <br /> ®In-Tank Gauging Probe. Model: 847390-109 ❑In-Tank Gauging Probe. Model: <br /> ®Annular Space or Vault Sensor. Model: Split tank w/Prem ❑Annular Space or Vault Sensor. Model: <br /> ®Piping Sump/Trench Sensor(s). Model: 794380-208 ❑Piping Sump/Trench Sensor(s). Model: <br /> ®Fill Sump Sensor(s). Model: 794380-208 ❑Fill Sump Sensor(s). Model: <br /> ®Mechanical Line Leak Detector. Model: VMI LD2000 ❑Mechanical Line Leak Detector. Model: <br /> ❑Electronic Line Leak Detector. Model: ❑Electronic Line Leak Detector. Model: <br /> ®Tank Overfill/High-Level Sensor. Model: ATG ❑Tank Overfill/High-Level Sensor. Model: <br /> ❑Other(specify equipment type and model in Section E on Page 2). ❑Other(specify equipment type and model in Section E on Page 2). <br /> Dispenser ID: 1-2 Dispenser ID: 3-4 <br /> N Dispenser Containment Sensor(s). Model: 794380-208 ®Dispenser Containment Sensor(s). Model: 794380-208 <br /> N Shear Valve(s). ®Shear Valve(s). <br /> ❑Dispenser Containment Float(s)and Chain(s). ❑Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: 5-6 Dispenser ID: 7-8 <br /> ®Dispenser Containment Sensor(s). Model: 794380-208 ®Dispenser Containment Sensor(s). Model: 794380-208 <br /> ®Shear Valve(s). ®Shear Valve(s). <br /> ❑Dispenser Containment Float(s)and Chain(s). ❑Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: 9-10 Dispenser ID: 11-12 <br /> ®Dispenser Containment Sensor(s). Model: 794380-208 ®Dispenser Containment Sensor(s). Model: 794380-208 <br /> ®Shear Valve(s). ®Shear Valve(s). <br /> ❑Dispenser Containment Float(s)and Chain(s). ❑Dispenser Containment Float(s)and Chain(s). <br /> *If the facility contains more tanks or dispensers,copy this form. Include information for every tank and dispenser at the facility. <br /> C. Certification -I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' <br /> guidelines. Attached to this Certification is information (e.g. manufacturers' checklists) necessary to verify that this information is <br /> correct and a Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating such reports,I have also <br /> attached a copy of the report;(check all that apply): ❑System set-up ®Alarm history report <br /> Technician Name(print): Jeff Conger Signature: <br /> Certification No.: A22219 License.No.: ICC#1801782 UT CSLB#894932 <br /> Testing Company Name: Pinnacle Fuel Compliance Services, Inc. Phone No.:(408) 206-9840 <br /> Testing Company Address: P.O. Box 32849 San Jose, CA 95152-2849 Date of Testing/Servicing: 3/8/2018 <br /> Page 1 of 3 <br />
The URL can be used to link to this page
Your browser does not support the video tag.