My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WORK PLANS
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
W
>
WEST
>
4747
>
2900 - Site Mitigation Program
>
PR0517529
>
WORK PLANS
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/24/2020 5:34:05 PM
Creation date
6/24/2020 2:11:06 PM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2900 - Site Mitigation Program
File Section
WORK PLANS
RECORD_ID
PR0517529
PE
2950
FACILITY_ID
FA0013491
FACILITY_NAME
CHEVRON SERVICE STATION #200794
STREET_NUMBER
4747
Direction
N
STREET_NAME
WEST
STREET_TYPE
LN
City
STOCKTON
Zip
95202
APN
10437010
CURRENT_STATUS
01
SITE_LOCATION
4747 N WEST LN
QC Status
Approved
Scanner
LSauers
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
18
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SECOR <br /> International Incorporated <br /> September 19, 2001 <br /> Project 077.43572.110 <br /> Ms. Margaret Lagorio <br /> San Joaquin County Environmental Health Department <br /> 304 East Weber Street, 3`d Floor <br /> Stockton, California 95202 <br /> Re: Work Plan for Site Assessment <br /> Chevron Service Station#20-0794 <br /> 4747 North West Lane <br /> Stockton, California <br /> Dear Ms. Lagorio: <br /> SECOR International Incorporated (SECOR), on behalf of Chevron Products Company <br /> (Chevron), presents this work plan for site assessment activities consisting of the <br /> drilling and installation of three groundwater monitoring wells and the possible <br /> advancement of seven cone penetrometer test(CPT)borings along the southern property <br /> boundary. The purpose of this assessment is to determine if methyl tertiary butyl ether <br /> (MtBE) is a potential threat to a municipal supply well located to the south of the site <br /> (Figure 1). <br /> This work plan includes a brief discussion of site background, summary of previous <br /> investigations, and proposed scope of work. <br /> SITE BACKGROUND <br /> The site is an operating Chevron service station located in a commercial area of <br /> Stockton, California. The current station facilities include two dispenser islands and a <br /> mini-mart under a common canopy, three gasoline underground storage tanks (USTs), <br /> and a carwash. Figure 2 shows the current station facilities. <br /> Information on any previous investigations was not available. <br /> PROPOSED SCOPE OF WORK <br /> The scope of work for this site assessment will include the drilling and installation of <br /> three groundwater monitoring wells at the general locations shown on Figure 2. Based <br /> on the results of the soil and groundwater chemical analyses, the CPT borings may be <br /> completed to assess soil stratigraphy and to collect soil and groundwater samples for <br /> chemical analysis. <br /> 3017 Kilgore Road, Suite 100, Rancho Cordova, CA 95670 916.861.0400 916.861.0430 Fax www.secor.com <br />
The URL can be used to link to this page