Quarterly Groundwater Monitoring Report - First Quarter 2016 <br /> L&M Operable Unit- West Weber Avenue and North Lincoln Street, Stockton, CA <br /> April 29, 2016 <br /> B-Zone wells MW-43, MW-48, MW-49, and MW-50 historically contain sheen or a measurable SPH <br /> thickness, but due to the product skimmers in these wells, they were not measured during the <br /> 1 Q 16 event. <br /> C-Zone: <br /> During 1 Q16, measurable SPH or SPH-sheen was not observed in any C-Zone wells. <br /> D-Zone: <br /> During 1 Q16, measurable SPH or SPH-sheen was not observed in any D-Zone wells. <br /> A summary of 1 Q16 SPH sheen is provided in the following table. <br /> Well Aquifer Zone SPH Thickness <br /> Identification 1Q16 (Feet) <br /> 2AMW-13 A Sheen <br /> 2AMW-14 A NA <br /> MW-43 B NA <br /> MW-47 B Sheen <br /> MW-48 B NA <br /> MW-49 B NA <br /> MW-50 B NA <br /> MW-52 B 0.04 <br /> NA=Not Assessed due to a sock or skimmer in monitoring well;SPH or sheen is likely present. <br /> 2.2.4 Quality Assurance and Quality Control for Groundwater Samples <br /> Three field technicians from G-R conducted the 1 Q16 M&S event over the course of three days. <br /> A total of 7 equipment blanks were collected, one for each tech for each day, and analyzed for <br /> the presence of petroleum hydrocarbons compounds. All constituents were reported as below <br /> laboratory reporting limit (LRL). No cross-contamination is suspected to have occurred during <br /> the 1 Q16 event. <br /> Analytical data from the 1Q16 groundwater sampling event were quality assured and quality <br /> controlled (QA/QC) using Stantec Lab Validation Form. The following validation notes are <br /> consistent with the quality assurance and quality control. Each set of issues corresponds directly <br /> with the denoted report (Appendix E). <br /> Laboratory Validation, report number 1259724 <br /> • For method blank 281359 and associated samples (MW-69 through MW-74 and 2A-MW-12 and <br /> 5 Stantec 7 <br />